{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6DL1131-6TD00-0HX1","brand":"Siemens","brandSlug":"siemens","productSlug":"6DL1131-6TD00-0HX1","canonicalUrl":"https://aoctrl.com/siemens/6DL1131-6TD00-0HX1","factsUrl":"https://aoctrl.com/api/mcp/products/6DL1131-6TD00-0HX1","rawCanonicalId":null},"summary":{"shortDescription":"SIMATIC ET 200SP HA, ET 200SP, digital ex-i input module, DI 4xNAMUR, suitable for BaseUnit type X1, channel diagnostics","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLC I/O & Expansion Modules"],"specifications":{"DI":"Yes","MSI":"Yes","Depth":"58 mm","Width":"20 mm","Height":"73 mm","Inputs":"10 byte; + 1 byte for QI information","Counter":"Yes","Outputs":"10 byte","I&M data":"Yes; I&M0 to I&M3","MAINT LED":"Yes; Yellow LED","Wire-break":"Yes; channel by channel","Group error":"Yes","Number, max.":"2; Channel 0 and 1","Short-circuit":"Yes; channel by channel","Time stamping":"No","For Signal \"0\"":"Max. 1.2 mA","For Signal \"1\"":"typ. 8 mA","Shielded, Max.":"500 m; Ex characteristic values must be observed; without shield applied on both sides and cable lengths of more than 200 m, measured value distortions can occur when using the inputs as counter/ frequency meter","Edge evaluation":"Yes; Positive edge, negative edge","Parameterizable":"Yes","Pulse extension":"Yes; 0.5 s, 1 s, 2 s","Weight, approx.":"55 g","lifecycle_stage":"unknown","Diagnostic alarm":"Yes","Firmware version":"V1.0","Isochronous mode":"No","Power loss, typ.":"1.2 W","Rated value (DC)":"8.2 V","Unshielded, Max.":"300 m; Ex characteristic values must be observed; without shield applied on both sides and cable lengths of more than 200 m, measured value distortions can occur when using the inputs as counter/ frequency meter","usable BaseUnits":"BU type X1","2-Wire Connection":"BU type X1","Number of outputs":"4","FW update possible":"Yes","Hardware interrupt":"Yes; channel by channel","At \"0\" To \"1\", Max.":"12 ms","At \"1\" To \"0\", Max.":"12 ms","Output voltage (DC)":"8.2 V","Between The Channels":"No","Diagnostics function":"Yes","For Signal \"0\", Max.":"1.2 mA","For Signal \"0\", Min.":"0.35 mA","For Signal \"1\", Max.":"6.4 mA","For Signal \"1\", Min.":"2.1 mA","Frequency measurement":"1 %","Isolation tested with":"further information on insulation can be found in the \"ET 200SP HA / ET 200SP modules for devices in hazardous areas” System Manual","Maintenance interrupt":"Yes","Redundancy capability":"No","Signal change flutter":"Yes; 2 to 32 signal changes","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; green/red DIAG LED","For Channel Diagnostics":"Yes; red LED","Po (power output), max.":"145 mW; applies for up to four circuits connected in parallel","Counting frequency, max.":"5 kHz","Number of digital inputs":"4; NAMUR","Short-circuit protection":"Yes","Current consumption, max.":"55 mA","Mechanical coding element":"Yes","Counting direction up/down":"Yes; Up","Flutter observation window":"Yes; 0.5 s, 1 s to 100 s in 1-s steps","Uo (no-load voltage), max.":"9.6 V","Vertical Installation, Max.":"60 °C","Vertical Installation, Min.":"-40 °C","Horizontal Installation, Max.":"70 °C","Horizontal Installation, Min.":"-40 °C","Monitoring the supply voltage":"Yes","Diagnostic information readable":"Yes","Digital inputs, parameterizable":"Yes","Io (short-circuit current), max.":"61 mA; applies for up to four circuits connected in parallel","Current consumption (rated value)":"50 mA","Monitoring of encoder power supply":"Yes","Between The Channels And Backplane Bus":"Yes","Co (permissible external capacity), max.":"3.6 µF; applies for up to four circuits connected in parallel","Monitoring of the supply voltage (PWR-LED)":"Yes; green PWR LED","PCS 7 configurable/integrated from version":"V9.1","Installation altitude above sea level, max.":"2 000 m","Lo (permissible external inductivity), max.":"13 mH; applies for up to four circuits connected in parallel","STEP 7 configurable/integrated from version":"STEP 7 V5.6 SP2 or higher","Single contact / changeover contact unconnected":"Yes","For Signal \"0\", Max. (Permissible Quiescent Current)":"0.5 mA","STEP 7 TIA Portal configurable/integrated from version":"STEP 7 V16 or higher with HSP","Single contact / changeover contact connected with 10 kΩ":"Yes","Between The Channels And The Power Supply Of The Electronics":"Yes; Electrical isolation between the channels and input voltage PME","Um (voltage at non-intrinsically safe connecting terminals), max.":"60 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$186.69","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b887e90f69db22b7c188891d8abf4102.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1506144&mlfb=6DL1131-6TD00-0HX1","alternativesUrl":"https://aoctrl.com/api/mcp/products/6DL1131-6TD00-0HX1/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6DL1131-6TD00-0HX1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6DL1131-6TD00-0HX1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}