{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6DL1134-6TB00-0HX1","brand":"Siemens","brandSlug":"siemens","productSlug":"6DL1134-6TB00-0HX1","canonicalUrl":"https://aoctrl.com/siemens/6DL1134-6TB00-0HX1","factsUrl":"https://aoctrl.com/api/mcp/products/6DL1134-6TB00-0HX1","rawCanonicalId":null},"summary":{"shortDescription":"SIMATIC ET 200SP HA, ET 200SP, analog ex-i HART input module, Ex-AI 2xI 2-Wire HART, suitable for BaseUnit type X1, channel diagnostics, 16bit, +/-0.3%","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLC I/O & Expansion Modules"],"specifications":{"MSI":"Yes","24 V":"Yes","Depth":"58 mm","Width":"20 mm","Height":"73 mm","I&M data":"Yes; I&M0 to I&M3","MAINT LED":"Yes; Yellow LED","0 to 20 mA":"Yes","Wire-break":"Yes; channel by channel","Group error":"Yes","4 mA to 20 mA":"Yes; 15 bit + sign","HART protocol":"Yes","Short-circuit":"Yes; channel by channel","Shielded, Max.":"500 m; Ex characteristic values must be observed","Parameterizable":"Yes","Weight, approx.":"55 g","lifecycle_stage":"unknown","Diagnostic alarm":"Yes","Firmware version":"V1.0","Isochronous mode":"No","Power loss, typ.":"1.2 W","Unshielded, Max.":"300 m; Ex characteristic values must be observed","usable BaseUnits":"BU type X1","2-Wire Connection":"BU type X1","Limit value alarm":"Yes","FW update possible":"Yes","Overflow/underflow":"Yes; channel by channel","Between The Channels":"No","Diagnostics function":"Yes","Isolation tested with":"further information on insulation can be found in the \"ET 200SP HA / ET 200SP modules for devices in hazardous areas” System Manual","Measurement principle":"integrating (Sigma-Delta)","Redundancy capability":"No","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; green/red DIAG LED","For Channel Diagnostics":"Yes; red LED","For current measurement":"2","Number of analog inputs":"2; Differential inputs","Po (power output), max.":"605 mW","Short-circuit protection":"Yes; Electronic disconnection in case of short-circuit, current limitation from 27 mA","Current consumption, max.":"92 mA; Peak load (all channels in short-circuit)","Mechanical coding element":"Yes","Number of smoothing levels":"4; None; 4/8/16 times","Uo (no-load voltage), max.":"26 V","Vertical Installation, Max.":"60 °C","Vertical Installation, Min.":"-40 °C","Horizontal Installation, Max.":"70 °C","Horizontal Installation, Min.":"-40 °C","Monitoring the supply voltage":"Yes","Address space per module, max.":"4 byte; + 0/1 byte for QI information","Cycle time (all channels), min.":"3 ms","Input resistance (4 mA to 20 mA)":"400 Ω; At 20 mA input current","Io (short-circuit current), max.":"93 mA","Output current per channel, max.":"28 mA","Current consumption (rated value)":"74 mA","Integration time, parameterizable":"Yes; channel by channel","Burden of 2-wire transmitter, max.":"750 Ω; At 20 mA input current","Crosstalk between the inputs, min.":"60 dB","Reparameterization possible in RUN":"Yes","Between The Channels And Backplane Bus":"Yes","Current, relative to input range, (+/-)":"0.2 %","Address space per module with HART, max.":"24 byte; + 0/1 byte for QI information","Co (permissible external capacity), max.":"99 nF","Monitoring of the supply voltage (PWR-LED)":"Yes; green PWR LED","PCS 7 configurable/integrated from version":"V9.1","Installation altitude above sea level, max.":"2 000 m","Lo (permissible external inductivity), max.":"4 mH","STEP 7 configurable/integrated from version":"STEP 7 V5.6 SP2 or higher","Ui (intrinsically safe input voltage), max.":"10 V","For Current Measurement As 2-Wire Transducer":"Yes","Address space per module with MultiHART, max.":"11 byte; + 0/1 byte for QI information","Linearity error (relative to input range), (+/-)":"0.01 %","Temperature error (relative to input range), (+/-)":"0.005 %/K","Resolution with overrange (bit including sign), max.":"16 bit","STEP 7 TIA Portal configurable/integrated from version":"STEP 7 V16 or higher with HSP","Between The Channels And The Power Supply Of The Electronics":"Yes; Electrical isolation between the channels and input voltage PME","Um (voltage at non-intrinsically safe connecting terminals), max.":"60 V","Interference voltage suppression for interference frequency f1 in Hz":"10 / 50 / 60 Hz","Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)":"0.05 %","Series mode interference (peak value of interference < rated value of input range), min.":"60 dB"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b887e90f69db22b7c188891d8abf4102.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1506149&mlfb=6DL1134-6TB00-0HX1","alternativesUrl":"https://aoctrl.com/api/mcp/products/6DL1134-6TB00-0HX1/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6DL1134-6TB00-0HX1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6DL1134-6TB00-0HX1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}