{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6EP1331-1SH02","brand":"Siemens","brandSlug":"siemens","productSlug":"6EP1331-1SH02","canonicalUrl":"https://aoctrl.com/siemens/6EP1331-1SH02","factsUrl":"https://aoctrl.com/api/mcp/products/6EP1331-1SH02","rawCanonicalId":null},"summary":{"shortDescription":"LOGO!Power 24 V Stabilized power supply input: 100-240 V AC output: DC 24 V/1,3 A","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["DIN Rail Power Supplies"],"specifications":{"Top":"20 mm","Left":"0 mm","Note":"with natural convection","Input":"1-phase AC","Right":"0 mm","Bottom":"20 mm","Output":"+, -: 2 screw terminals each for 0.5 ... 2.5 mm²","CE mark":"Yes","Maximum":"4 A","I2t, max.":"0.8 A²·s","CB approval":"Yes","FM approval":"Class I, Div. 2, Group ABCD, T4","Installation":"Snaps onto DIN rail EN 60715 35x7.5/15","Supply input":"L, N: 1 screw terminal each for 0.5 ... 2.5 mm2 single-core/finely stranded","Current range":"0 ... 1.3 A","During Storage":"-40 ... +70 °C","MTBF at 40 °C":"1 729 757 h","Noise immunity":"EN 61000-6-2","Status display":"Green LED for output voltage OK","Mains buffering":"at Vin = 187 V","Marine approval":"ABS, BV, DNV, GL, LRS","On/off behavior":"No overshoot of Vout (soft start)","Weight, approx.":"0.17 kg","lifecycle_stage":"current","Adjustment range":"22.2 ... 26.4 V","During Operation":"-20 ... +55 °C","During Transport":"-40 ... +70 °C","Protection class":"Class II (without protective conductor)","Rated line range":"47 ... 63 Hz","Voltage range AC":"85 ... 264 V","Wide-range input":"Yes","Other Information":"Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)","Galvanic Isolation":"Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178","Voltage rise, typ.":"15 ms","Startup delay, max.":"0.5 s","Emitted interference":"EN 55022 Class B","Explosion protection":"ATEX (EX) II 3G Ex nA IIC T3","Connection technology":"screw-type terminals","Rated voltage Vout DC":"24 V","UL/cUL (CSA) approval":"cULus-listed (UL 508, CSA C22.2 No. 107.1), File E197259; cURus-recognized (UL 60950, CSA C22.2 No. 60950), File E151273","Built-in incoming fuse":"internal","Depth Of The Enclosure":"55 mm","Output voltage setting":"via potentiometer","Overvoltage resistance":"2.3 × Vin rated, 1.3 ms","Rated line frequency 1":"50 Hz","Rated line frequency 2":"60 Hz","Width Of The Enclosure":"54 mm","Height Of The Enclosure":"90 mm","Current limitation, typ.":"2 A","Short-circuit protection":"Constant current characteristic","Total tolerance, static ±":"3 %","Primary/secondary isolation":"Yes","Supply harmonics limitation":"not applicable","at rated input voltage 120 V":"0.7 A","at rated input voltage 230 V":"0.35 A","Output overvoltage protection":"Yes, according to EN 60950","Rated voltage value Vin rated":"100 ... 240 V","Supplied Active Power Typical":"30 W","Rated current value Iout rated":"1.3 A","Static load balancing, approx.":"1.5 %","Degree of protection (EN 60529)":"IP20","Residual ripple peak-peak, max.":"200 mV","Residual ripple peak-peak, typ.":"10 mV","Static mains compensation, approx.":"0.1 %","Mains buffering at Iout rated, min.":"40 ms; at Vin = 187 V","Humidity class according to EN 60721":"Climate class 3K3, 5 … 95% no condensation","Load step setting time 10 to 90%, typ.":"20 ms","Load step setting time 90 to 10%, typ.":"20 ms","Product Function Output Voltage Adjustable":"Yes","Property Of The Output Short-Circuit Proof":"Yes","Spikes peak-peak, max. (bandwidth: 20 MHz)":"300 mV","Spikes peak-peak, typ. (bandwidth: 20 MHz)":"20 mV","Switch-on current limiting (+25 °C), max.":"15 A","Parallel switching for enhanced performance":"Yes","Efficiency at Vout rated, Iout rated, approx.":"82 %","Power loss at Vout rated, Iout rated, approx.":"7 W","Protection in the mains power input (IEC 898)":"Recommended miniature circuit breaker: from 16 A characteristic B or from 10 A characteristic C","Dynamic mains compensation (Vin rated ±15 %), max.":"0.2 %","Product Feature Of The Enclosure Housing Can Be Lined Up":"Yes","Numbers of parallel switchable units for enhanced performance":"2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$202.69","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e9d7f5cd548653e4b5dd8bad8b62945f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=198359&mlfb=6EP1331-1SH02"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6EP1331-1SH02","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6EP1331-1SH02 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}