{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6EP1332-1SH12","brand":"Siemens","brandSlug":"siemens","productSlug":"6EP1332-1SH12","canonicalUrl":"https://aoctrl.com/siemens/6EP1332-1SH12","factsUrl":"https://aoctrl.com/api/mcp/products/6EP1332-1SH12","rawCanonicalId":null},"summary":{"shortDescription":"********* spare part ********** SITOP power 2.5 A, Univ. Line stabilized power supply input: 120-230 V AC (110-350 V DC) output: 24 V DC/2.5 A,","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["DIN Rail Power Supplies"],"specifications":{"Top":"100 mm","ATEX":"No","Left":"0 mm","IECEx":"No","Right":"0 mm","at DC":"110 ... 350 V","Bottom":"100 mm","DNV GL":"No","Maximum":"3.5 mA","Typical":"2.8 A","At Input":"L, N, PE: 1 screw terminal each for 2 x 0.5 ... 1.5 mm² finely stranded, 2 x 0.5 ... 2.5 mm² single-core","At Output":"L+, M: 1 screw terminal each for 2 x 0.5 ... 2.5 mm²","CE marking":"Yes","NEC Class 2":"No","Rated Range":"0 ... 2.5 A","Rated Value":"2.5 A","UL approval":"Yes; cULus-Listed (UL 508, CSA C22.2 No. 142), File E143289","CSA approval":"Yes; cULus-Listed (UL 508, CSA C22.2 No. 142), File E143289","EAC approval":"Yes","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","In The Feeder":"Recommended: 2-pole miniature circuit breaker from 10 A characteristic C or from 6 A characteristic D","Initial Value":"93 V","During Storage":"-25 ... +85 °C","Line Frequency":"47 ... 63 Hz","MTBF at 40 °C":"645 161 h","FM registration":"No","lifecycle_stage":"current","During Operation":"0 ... 60 °C; with natural convection","During Transport":"-25 ... +85 °C","Fastening Method":"Snaps onto DIN rail EN 60715 35x15, wall mounting","Full-Scale Value":"264 V","I2t value maximum":"3.5 A²·s","Other Information":"Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)","ULhazloc approval":"No","Galvanic Isolation":"Safety extra low output voltage Vout according to EN 60950-1","Maximum Rated Value":"230 V","Minimum Rated Value":"120 V","protection class IP":"IP20","Fuse Protection Type":"T 3.15 A (not accessible)","Bridging Of Equipment":"Yes","Efficiency In Percent":"85 %","Depth Of The Enclosure":"120 mm","Response Delay Maximum":"0.6 s","Width Of The Enclosure":"80 mm","Height Of The Enclosure":"135 mm","Voltage Curve At Output":"Controlled, isolated DC voltage","For Emitted Interference":"EN 55022 Class B","Nippon Kaiji Kyokai (NK)":"No","For Interference Immunity":"EN 61000-6-2","cCSAus, Class 1, Division 2":"No","Load Step 100 To 50% Typical":"1 ms","Load Step 50 To 100% Typical":"1 ms","at rated input voltage 120 V":"1.3 A","at rated input voltage 230 V":"0.7 A","Supplied Active Power Typical":"60 W","Type Of Electrical Connection":"screw-type terminals","at output 1 at DC rated value":"24 V","For Mains Harmonics Limitation":"not applicable","Overvoltage Overload Capability":"2.3 × Vin rated, 1.3 ms","Design Of Input Wide Range Input":"Yes","Type Of The Power Supply Network":"1-phase AC or DC","output voltage at DC rated value":"24 V","Lloyds Register of Shipping (LRS)":"No","Design Of Short-Circuit Protection":"Constant current characteristic","On Slow Fluctuation Of Ohm Loading":"0.2 %","Operating Resource Protection Class":"Class I","Design Of The Overvoltage Protection":"Yes, according to EN 60950","Display Version For Normal Operation":"Green LED for 24 V OK","On Slow Fluctuation Of Input Voltage":"0.1 %","At Short-Circuit During Operation Typical":"2.8 A","French marine classification society (BV)":"No","Relative Overall Tolerance Of The Voltage":"1 %","Operating Condition Of The Mains Buffering":"at Vin = 120 V, > 80 ms (typ. 100 ms) at Vin = 187 V","Product Function Output Voltage Adjustable":"No","Property Of The Output Short-Circuit Proof":"Yes","Galvanic Isolation Between Input And Output":"Yes","American Bureau of Shipping Europe Ltd. (ABS)":"No","environmental category according to IEC 60721":"Climate class 3K3, 5 … 95% no condensation","On Short-Circuiting During The Start-Up Typical":"2.8 A","Behavior Of The Output Voltage When Switching On":"No overshoot of Vout (soft start)","current limitation of inrush current at 25 °C maximum":"33 A","Product Feature Of The Enclosure Housing Can Be Lined Up":"Yes","At Rated Output Voltage For Rated Value Of The Output Current Typical":"11 W","Number Of Parallel-Switched Equipment Resources For Increasing The Power":"10","Buffering Time For Rated Value Of The Output Current In The Event Of Power Failure Minimum":"20 ms","Relative Control Precision Of The Output Voltage With Rapid Fluctuation Of The Input Voltage By +/- 15% Typical":"0.3 %"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$170.66","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e9d7f5cd548653e4b5dd8bad8b62945f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=404308&mlfb=6EP1332-1SH12"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6EP1332-1SH12","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6EP1332-1SH12 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}