{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6EP1332-2BA00","brand":"Siemens","brandSlug":"siemens","productSlug":"6EP1332-2BA00","canonicalUrl":"https://aoctrl.com/siemens/6EP1332-2BA00","factsUrl":"https://aoctrl.com/api/mcp/products/6EP1332-2BA00","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SITOP PSU100M, 6EP1332-2BA00, 3.7 A rated output, 120/230 VAC dual input, IP20, DIN-rail mount.","salesMarkdown":"The Siemens 6EP1332-2BA00 is a SITOP PSU100M power supply rated for 3.7 A continuous output. It accepts dual AC input ranges — 93…132 V (120 V nominal) and 187…264 V (230 V nominal) at 50/60 Hz — so it lands on either a 120 V or 230 V line without rewiring. That dual-range input is the critical path for a panel build: set the wire jumper on the terminal block to match the incoming supply before energizing. Output is SELV per EN 60950-1, galvanically isolated from the input. The internal fuse is rated T 3.15 A/250 V (not user-accessible). For the feeder, Siemens recommends a 6 A miniature circuit breaker, characteristic C. Snaps onto DIN rail EN 60715 35×7.5/15. Ambient operating range is 0…60 °C with natural convection; no forced air required. Storage and transport range is -40…+85 °C. Dimensions: top and bottom clearance is 50 mm each; left and right clearance is 0 mm — the unit can be mounted flush side-to-side with adjacent devices. That matters when you're packing modules into a tight DIN rail row. Not NEC Class 2. If your design requires Class 2 power, this unit does not meet that marking. The 3.7 A rating at 120/230 VAC is the headline spec that confirms fit for a BOM line calling for a 3.7 A SELV supply. The dual input range and DIN-rail footprint mean it drops into a standard control panel without panel modifications.","metaTitle":"Siemens 6EP1332-2BA00 SITOP PSU100M Power Supply, 3.7 A, 120","metaDescription":"Active Siemens SITOP PSU100M 6EP1332-2BA00 power supply, 3.7 A rated output, dual AC input 120/230 VAC, UL/CSA/EAC listed. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["DIN Rail Power Supplies"],"specifications":{"Top":"50 mm","ATEX":"No","Left":"0 mm","IECEx":"No","Right":"0 mm","title":"6EP1332-2BA00","Bottom":"50 mm","DNV GL":"No","1 at AC":"93 ... 132 V","2 at AC":"187 ... 264 V","Maximum":"3.5 mA","Typical":"0.4 mA","At Input":"L, N, PE: 1 screw terminal each for 0.5 ... 2.5 mm² single-core/finely stranded","At Output":"L+: 1 screw terminal for 0.5 ... 2.5 mm²; M: 2 screw terminals for 0.5 ... 2.5 mm²","CE marking":"Yes","NEC Class 2":"No","Rated Range":"0 ... 3.7 A","Rated Value":"3.7 A","UL approval":"Yes; cULus-Listed (UL 508, CSA C22.2 No. 142), File E143289; cURus-Recognized (UL 1950, CSA C22.2 No. 60950), File 151273; UL 1310","description":"********* spare part ********** SITOP power 4 A, stabilized power supply input: 120/230 V AC output: 24 V DC/3.8 A","CSA approval":"Yes; cULus-Listed (UL 508, CSA C22.2 No. 142), File E143289; cURus-Recognized (UL 1950, CSA C22.2 No. 60950), File 151273; UL 1310","EAC approval":"Yes","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","In The Feeder":"Recommended miniature circuit breaker: from 6 A characteristic C","Initial Value":"Set via wire jumper","During Storage":"-40 ... +85 °C","Line Frequency":"47 ... 63 Hz","FM registration":"No","lifecycle_stage":"current","During Operation":"0 ... 60 °C; with natural convection","During Transport":"-40 ... +85 °C","Fastening Method":"Snaps onto DIN rail EN 60715 35x7.5/15","I2t value maximum":"0.8 A²·s","Other Information":"Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)","ULhazloc approval":"No","Galvanic Isolation":"Safety extra low output voltage Vout according to EN 60950-1","1 at AC rated value":"120 V","2 at AC rated value":"230 V","protection class IP":"IP20","Fuse Protection Type":"T 3,15 A/250 V (not accessible)","Bridging Of Equipment":"Yes; only permissable at ambient temperature 0 °C to 50 °C","Efficiency In Percent":"80 %","Depth Of The Enclosure":"125 mm","Response Delay Maximum":"3 s","Width Of The Enclosure":"75 mm","Height Of The Enclosure":"125 mm","Voltage Curve At Output":"Controlled, isolated DC voltage","For Emitted Interference":"EN 55022 Class B","Nippon Kaiji Kyokai (NK)":"No","Adjustable Output Voltage":"22.8 ... 26.4 V","For Interference Immunity":"EN 61000-6-2","cCSAus, Class 1, Division 2":"No","Load Step 100 To 50% Typical":"0.2 ms","Load Step 50 To 100% Typical":"0.2 ms","at rated input voltage 120 V":"1.8 A","at rated input voltage 230 V":"0.7 A","Supplied Active Power Typical":"90 W","Type Of Electrical Connection":"screw-type terminals","at output 1 at DC rated value":"24 V","For Mains Harmonics Limitation":"EN 61000-3-2","Type Of Output Voltage Setting":"via potentiometer; only permissible at ambient temperatur 0 °C to +50 °C","Overvoltage Overload Capability":"2.3 × Vin rated, 1.3 ms","Design Of Input Wide Range Input":"No","Type Of The Power Supply Network":"1-phase AC","output voltage at DC rated value":"24 V","Lloyds Register of Shipping (LRS)":"No","Response Value Current Limitation":"3.8 ... 4.1 A","Design Of Short-Circuit Protection":"Electronic shutdown, automatic restart","On Slow Fluctuation Of Ohm Loading":"0.2 %","Operating Resource Protection Class":"Class I","Design Of The Overvoltage Protection":"Yes, according to EN 60950","Display Version For Normal Operation":"Green LED for 24 V OK","On Slow Fluctuation Of Input Voltage":"0.1 %","French marine classification society (BV)":"No","Relative Overall Tolerance Of The Voltage":"3 %","Operating Condition Of The Mains Buffering":"at Vin = 93/187 V","Product Function Output Voltage Adjustable":"Yes","Property Of The Output Short-Circuit Proof":"Yes","Galvanic Isolation Between Input And Output":"Yes","American Bureau of Shipping Europe Ltd. (ABS)":"No","environmental category according to IEC 60721":"Climate class 3K3, 5 … 95% no condensation","Behavior Of The Output Voltage When Switching On":"No overshoot of Vout (soft start)","current limitation of inrush current at 25 °C maximum":"32 A","Product Feature Of The Enclosure Housing Can Be Lined Up":"Yes","At Rated Output Voltage For Rated Value Of The Output Current Typical":"22 W","Number Of Parallel-Switched Equipment Resources For Increasing The Power":"2","Buffering Time For Rated Value Of The Output Current In The Event Of Power Failure Minimum":"10 ms","Relative Control Precision Of The Output Voltage With Rapid Fluctuation Of The Input Voltage By +/- 15% Typical":"0.3 %"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$282.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e9d7f5cd548653e4b5dd8bad8b62945f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=92840&mlfb=6EP1332-2BA00"},"ai":{"faq":[{"question":"What approvals does 6EP1332-2BA00 carry?","answer":"CE, cULus-Listed (UL 508, CSA C22.2 No. 142), cURus-Recognized (UL 1950, CSA C22.2 No. 60950), UL 1310, and EAC. No ATEX, IECEx, FM, or UL hazloc."},{"question":"What is the rated output current and input voltage range?","answer":"Rated output current is 3.7 A. Input voltage ranges are 93…132 V AC (120 V nominal) and 187…264 V AC (230 V nominal) at 47…63 Hz."},{"question":"Does 6EP1332-2BA00 meet NEC Class 2?","answer":"No, it is not NEC Class 2 listed."},{"question":"What is the recommended upstream protection?","answer":"Siemens recommends a 6 A miniature circuit breaker, characteristic C, in the feeder."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6EP1332-2BA00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6EP1332-2BA00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}