{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6EP1334-2AA01-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6EP1334-2AA01-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6EP1334-2AA01-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6EP1334-2AA01-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"SITOP smart 240 W Stabilized power supply input: 120/230 V AC, output: DC 24 V/10 A Option for for wall mounting","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Power Supplies"],"specifications":{"Top":"50 mm","ATEX":"No","Left":"0 mm","IECEx":"No","Right":"0 mm","Bottom":"50 mm","DNV GL":"Yes","1 at AC":"85 ... 132 V","2 at AC":"170 ... 264 V","Maximum":"3.5 mA","Typical":"0.8 mA","At Input":"L, N, PE: 1 screw terminal each for 0.5 ... 2.5 mm² single-core/finely stranded","At Output":"L+, M: 2 screw terminals each for 0.5 ... 2.5 mm²","CE marking":"Yes","NEC Class 2":"No","Rated Range":"0 ... 12 A; 12 A up to +45 °C","Rated Value":"10 A","UL approval":"Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259","CSA approval":"Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259","EAC approval":"Yes","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","In The Feeder":"Recommended miniature circuit breaker: from 10 A characteristic C","Initial Value":"Set by means of selector switch on the device","During Storage":"-40 ... +85 °C","Line Frequency":"47 ... 63 Hz","MTBF at 40 °C":"1 460 803 h","FM registration":"No","lifecycle_stage":"current","During Operation":"0 ... 60 °C; with natural convection","During Transport":"-40 ... +85 °C","Fastening Method":"Wall mounting","I2t value maximum":"3.3 A²·s","Other Information":"Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)","ULhazloc approval":"No","Galvanic Isolation":"Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178","1 at AC rated value":"120 V","2 at AC rated value":"230 V","protection class IP":"IP20","Fuse Protection Type":"T 6.3 A/250 V (not accessible)","Bridging Of Equipment":"Yes","Efficiency In Percent":"90 %","Shipbuilding Approval":"DNV GL","Depth Of The Enclosure":"125 mm","Response Delay Maximum":"0.1 s","Width Of The Enclosure":"70 mm","Height Of The Enclosure":"125 mm","Voltage Curve At Output":"Controlled, isolated DC voltage","For Emitted Interference":"EN 55022 Class B","Nippon Kaiji Kyokai (NK)":"No","Adjustable Output Voltage":"22.8 ... 28 V","For Interference Immunity":"EN 61000-6-2","cCSAus, Class 1, Division 2":"No","Load Step 100 To 50% Typical":"0.2 ms","Load Step 50 To 100% Typical":"0.2 ms","at rated input voltage 120 V":"4.1 A","at rated input voltage 230 V":"2.4 A","Supplied Active Power Typical":"288 W","Type Of Electrical Connection":"screw-type terminals","at output 1 at DC rated value":"24 V","Type Of Output Voltage Setting":"via potentiometer","Overvoltage Overload Capability":"2.3 × Vin rated, 1.3 ms","Design Of Input Wide Range Input":"No","Type Of The Power Supply Network":"1-phase AC","output voltage at DC rated value":"24 V","At Short-Circuit During Operation":"200 ms","Lloyds Register of Shipping (LRS)":"No","Response Value Current Limitation":"12.5 ... 13.5 A","Design Of Short-Circuit Protection":"Constant current characteristic","On Slow Fluctuation Of Ohm Loading":"0.5 %","Operating Resource Protection Class":"Class I","Design Of The Overvoltage Protection":"< 33 V","Display Version For Normal Operation":"Green LED for 24 V OK","On Slow Fluctuation Of Input Voltage":"0.1 %","On Short-Circuiting During The Start-Up":"100 ms","At Short-Circuit During Operation Typical":"33 A","French marine classification society (BV)":"No","Relative Overall Tolerance Of The Voltage":"3 %","Operating Condition Of The Mains Buffering":"at Vin = 93/187 V","Product Function Output Voltage Adjustable":"Yes","Property Of The Output Short-Circuit Proof":"Yes","Galvanic Isolation Between Input And Output":"Yes","American Bureau of Shipping Europe Ltd. (ABS)":"No","environmental category according to IEC 60721":"Climate class 3K3, 5 … 95% no condensation","On Short-Circuiting During The Start-Up Typical":"30 A","Behavior Of The Output Voltage When Switching On":"Overshoot of Vout approx. 4 %","current limitation of inrush current at 25 °C maximum":"65 A","Product Feature Of The Enclosure Housing Can Be Lined Up":"Yes","At Rated Output Voltage For Rated Value Of The Output Current Typical":"27 W","Number Of Parallel-Switched Equipment Resources For Increasing The Power":"2","Buffering Time For Rated Value Of The Output Current In The Event Of Power Failure Minimum":"20 ms","Relative Control Precision Of The Output Voltage With Rapid Fluctuation Of The Input Voltage By +/- 15% Typical":"0.3 %"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e9d7f5cd548653e4b5dd8bad8b62945f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=221849&mlfb=6EP1334-2AA01-0AB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6EP1334-2AA01-0AB0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6EP1334-2AA01-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6EP1334-2AA01-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}