{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6EP1732-0AA00","brand":"Siemens","brandSlug":"siemens","productSlug":"6EP1732-0AA00","canonicalUrl":"https://aoctrl.com/siemens/6EP1732-0AA00","factsUrl":"https://aoctrl.com/api/mcp/products/6EP1732-0AA00","rawCanonicalId":null},"summary":{"shortDescription":"********** spare part ********* SITOP power 2 A, DC/DC stabilized power supply input: 48/60/110 V DC output: 24 V DC/2 A","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["DIN Rail Power Supplies"],"specifications":{"Top":"50 mm","ATEX":"No","Left":"0 mm","IECEx":"No","Right":"0 mm","at DC":"38 ... 121 V","Bottom":"50 mm","DNV GL":"No","Maximum":"3.5 mA","Typical":"0.7 mA","At Input":"L+, M1, PE: 1 screw terminal each for 2 x 0.5 ... 2.5/1.5 mm² single-core/finely stranded","At Output":"L+, M: 1 screw terminal each for 2 x 0.5 ... 2.5 mm²","CE marking":"Yes","NEC Class 2":"No","Rated Range":"0 ... 2 A","Rated Value":"2 A","UL approval":"Yes; cULus-Listed (UL 508, CSA C22.2 No. 142), File E179336","CSA approval":"Yes; cULus-Listed (UL 508, CSA C22.2 No. 142), File E179336","EAC approval":"Yes","In The Feeder":"Recommended miniature circuit breaker: 10 to 25 A characteristic B or 6 to 25 A characteristic C, suitable for DC","During Storage":"-40 ... +70 °C","MTBF at 40 °C":"1 580 078 h","FM registration":"No","lifecycle_stage":"current","During Operation":"0 ... 70 °C; with natural convection","During Transport":"-40 ... +70 °C","Fastening Method":"Snaps onto DIN rail EN 60715 35x15","Other Information":"Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)","ULhazloc approval":"No","Galvanic Isolation":"Safety extra low output voltage Vout according to EN 60950-1","protection class IP":"IP20","Fuse Protection Type":"T 2.5 A (not accessible)","Bridging Of Equipment":"Yes","Efficiency In Percent":"84 %","Depth Of The Enclosure":"120 mm","Response Delay Maximum":"3 s","Width Of The Enclosure":"80 mm","Height Of The Enclosure":"135 mm","Voltage Curve At Output":"Controlled, isolated DC voltage","For Emitted Interference":"EN 55022 Class B","Nippon Kaiji Kyokai (NK)":"No","Adjustable Output Voltage":"23.5 ... 26.5 V","For Interference Immunity":"EN 61000-6-2","at rated input voltage 48 V":"1.2 A","cCSAus, Class 1, Division 2":"No","Load Step 100 To 50% Typical":"2.5 ms","Load Step 50 To 100% Typical":"2.5 ms","at rated input voltage 110 V":"0.5 A","Supplied Active Power Typical":"48 W","Type Of Electrical Connection":"screw-type terminals","at output 1 at DC rated value":"24 V","For Mains Harmonics Limitation":"not applicable","Type Of Output Voltage Setting":"via potentiometer","Design Of Input Wide Range Input":"Yes","Type Of The Power Supply Network":"DC voltage","output voltage at DC rated value":"24 V","Lloyds Register of Shipping (LRS)":"No","Response Value Current Limitation":"2.1 ... 3 A","Design Of Short-Circuit Protection":"Electronic shutdown, automatic restart","On Slow Fluctuation Of Ohm Loading":"0.4 %","Operating Resource Protection Class":"Class I","Design Of The Overvoltage Protection":"Yes, suppressor diode at output","Display Version For Normal Operation":"Green LED for 24 V OK","On Slow Fluctuation Of Input Voltage":"0.1 %","French marine classification society (BV)":"No","Relative Overall Tolerance Of The Voltage":"1 %","Operating Condition Of The Mains Buffering":"at Vin = 48 V","Product Function Output Voltage Adjustable":"Yes","Property Of The Output Short-Circuit Proof":"Yes","Galvanic Isolation Between Input And Output":"Yes","American Bureau of Shipping Europe Ltd. (ABS)":"No","environmental category according to IEC 60721":"Climate class 3K3, 5 … 95% no condensation","Behavior Of The Output Voltage When Switching On":"Overshoot of Vout on startup max. 25 V","current limitation of inrush current at 25 °C maximum":"33 A","Product Feature Of The Enclosure Housing Can Be Lined Up":"Yes","At Rated Output Voltage For Rated Value Of The Output Current Typical":"9 W","Number Of Parallel-Switched Equipment Resources For Increasing The Power":"2","Buffering Time For Rated Value Of The Output Current In The Event Of Power Failure Minimum":"5 ms","Relative Control Precision Of The Output Voltage With Rapid Fluctuation Of The Input Voltage By +/- 15% Typical":"0.3 %"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$118.05","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a5769414382c641dfac989ba9b0ed598.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=107569&mlfb=6EP1732-0AA00"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6EP1732-0AA00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6EP1732-0AA00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}