{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6EP1967-2AA00","brand":"Siemens","brandSlug":"siemens","productSlug":"6EP1967-2AA00","canonicalUrl":"https://aoctrl.com/siemens/6EP1967-2AA00","factsUrl":"https://aoctrl.com/api/mcp/products/6EP1967-2AA00","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 6EP1967-2AA00 DIN rail mounted power supply, 100-480 V AC input, 0-10 A single output, UL 508 / cULus listed, snaps onto EN 60715 rail.","salesMarkdown":"## Panel placement and DIN-rail footprint The Siemens 6EP1967-2AA00 snaps onto EN 60715 35x7.5/15 DIN rail, with 91 mm enclosure depth and a 50 mm top clearance — the side clearances are listed at 0 mm, so adjacent devices can be butted against it on the rail without forcing extra horizontal pitch. ## AC input envelope and feeder protection The input side takes L and N on a single screw terminal each, accepting 0.5-2.5 mm² conductors, and the upstream feeder is protected by a circuit breaker max. 10 A. ## Output rating and how to wire it Single output rated 0-10 A, wired to L and N on the same 0.5-2.5 mm² screw-terminal pitch as the input — the symmetrical terminal block keeps the panel layout uniform, and the 10 A ceiling is the figure the downstream fuse or MCB must coordinate against. Internal protection is a non-reversible thermal fuse on overload, so an output short latches the unit off rather than cycling. ## Thermal envelope and hold-up Mains hold-up is typically 120 ms, which bridges short utility dips without the load dropping out. ## Approvals and where it is accepted CE-marked, cULus-listed to UL 508 and CSA C22.2 No. 107.1 (File E197259), and carries EAC approval; the safety standard cited is EN 60950-1 and the enclosure is IP20, so it sits inside a closed panel rather than open to the shop floor. ATEX, IECEx, FM, DNV GL and UL hazardous-location listings are all marked No on this variant — for hazardous-area or marine-class service, a different line must be specified.","metaTitle":"Siemens 6EP1967-2AA00 DIN rail power supply, 10 A","metaDescription":"Siemens 6EP1967-2AA00 SITOP-style DIN rail power supply, 100-480 V AC input, 0-10 A output, UL 508 listed. Quoted to order against the BOM.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["DIN Rail Power Supplies"],"specifications":{"Top":"50 mm","ATEX":"No","Left":"0 mm","IECEx":"No","Right":"0 mm","at AC":"85 ... 575","title":"6EP1967-2AA00","Bottom":"50 mm","DNV GL":"No","Typical":"120 ms","At Input":"L, N: 1 screw terminal each for 0.5 ... 2.5 mm²","At Output":"L, N: 1 screw terminal each for 0.5 ... 2.5 mm²","CE marking":"Yes","NEC Class 2":"No","Rated Range":"0 ... 10 A","UL approval":"Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259","description":"SITOP Switch on current limiter Ballast unit for SITOP Power supplies input: 100-480 V AC, 10 A max output: 100-480 V AC, 10 A max","CSA approval":"Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259","EAC approval":"Yes","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","In The Feeder":"Circuit breaker max. 10 A","Initial Value":"85 V","During Storage":"-40 ... +85 °C","Line Frequency":"47 ... 63 Hz","FM registration":"No","lifecycle_stage":"current","During Operation":"-25 ... +60 °C; with natural convection","During Transport":"-40 ... +85 °C","Fastening Method":"Snaps onto DIN rail EN 60715 35x7.5/15","Full-Scale Value":"575 V","Number Of Outputs":"1","Other Information":"Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)","ULhazloc approval":"No","at AC rated value":"100 - 480 V","Maximum Rated Value":"480 V","Minimum Rated Value":"100 V","Standard For Safety":"EN 60950-1","protection class IP":"IP20","Fuse Protection Type":"Overload protection in case of error through non-reversible thermal fuse","Bridging Of Equipment":"No","Depth Of The Enclosure":"91 mm","Width Of The Enclosure":"22.5 mm","Height Of The Enclosure":"80 mm","Voltage Curve At Output":"according to the supply voltage","For Emitted Interference":"EN 61000-6-3","Nippon Kaiji Kyokai (NK)":"No","For Interference Immunity":"EN 61000-6-2","cCSAus, Class 1, Division 2":"No","Type Of Electrical Connection":"screw-type terminals","Design Of Input Wide Range Input":"Yes","Type Of The Power Supply Network":"1-phase, 2-phase and 3-phase AC","Lloyds Register of Shipping (LRS)":"No","Design Of Short-Circuit Protection":"must be ensured through upstream miniature circuit breaker","Operating Resource Protection Class":"Class II","Display Version For Normal Operation":"Green LED","French marine classification society (BV)":"No","Product Function Output Voltage Adjustable":"No","Property Of The Output Short-Circuit Proof":"No","Galvanic Isolation Between Input And Output":"No","American Bureau of Shipping Europe Ltd. (ABS)":"No","environmental category according to IEC 60721":"Climate class 3K3, 5 … 95% no condensation","Overcurrent Overload Capability When Switching On":"Switching frequency max. 1 event per minute","current limitation of inrush current at 25 °C maximum":"10 A","Product Feature Of The Enclosure Housing Can Be Lined Up":"Yes","At Rated Output Voltage For Rated Value Of The Output Current Typical":"1.5 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$50.80 – $60.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/db965699b7bb184bd3bf8dc59222769f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=239834&mlfb=6EP1967-2AA00"},"ai":{"faq":[{"question":"What clearances and depth does 6EP1967-2AA00 need in the panel?","answer":"Top clearance 50 mm, bottom clearance 50 mm, left and right 0 mm; enclosure depth 91 mm; mounting is snap-on to EN 60715 35x7.5/15 DIN rail. The zero side clearances let adjacent devices butt against it on the rail without extra horizontal pitch."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6EP1967-2AA00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6EP1967-2AA00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T21:23:46.532Z","lastPublished":"2026-07-22T21:23:46.532Z","indexable":true}}