{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6EP4333-0SB00-0AY0","brand":"Siemens","brandSlug":"siemens","productSlug":"6EP4333-0SB00-0AY0","canonicalUrl":"https://aoctrl.com/siemens/6EP4333-0SB00-0AY0","factsUrl":"https://aoctrl.com/api/mcp/products/6EP4333-0SB00-0AY0","rawCanonicalId":null},"summary":{"shortDescription":"SITOP PSU2600 24 V/5 A Stabilized power supply input: 230 V AC output: 24 V DC/5 A","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["DIN Rail Power Supplies"],"specifications":{"Top":"50 mm","ATEX":"No","Left":"0 mm","IECEx":"No","Right":"0 mm","at DC":"88 ... 265 V","Bottom":"50 mm","DNV GL":"No","Maximum":"3.5 mA","Typical":"1.1 mA","At Input":"L1, N, PE: 1 screw terminal each for 0.2 ... 2.5 mm² single-core/finely stranded","At Output":"+, -: 2 screw terminals each for 0.2 ... 2.5 mm²","CE marking":"Yes","NEC Class 2":"No","Rated Range":"0 ... 5 A; +60 °C","Rated Value":"5 A","UL approval":"Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259","CSA approval":"Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259","EAC approval":"Yes","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","In The Feeder":"None required. Fuse protection starting from 6 A Char. C possible","Initial Value":"85 V","During Storage":"-40 ... +85 °C","Line Frequency":"47 ... 63 Hz","FM registration":"No","lifecycle_stage":"current","During Operation":"0 ... 60 °C; with natural convection","During Transport":"-40 ... +85 °C","Fastening Method":"Snaps onto DIN rail EN 60715 35x7.5/15","Full-Scale Value":"264 V","Other Information":"Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)","ULhazloc approval":"No","Galvanic Isolation":"Safety extra low output voltage Vout according to EN 60950-1","Maximum Rated Value":"230 V","Minimum Rated Value":"120 V","protection class IP":"IP20","Fuse Protection Type":"3.15 A","Bridging Of Equipment":"No","Efficiency In Percent":"89 %","Depth Of The Enclosure":"125 mm","For Auxiliary Contacts":"13, 14 (alarm signal): 1 screw terminal each for 0.05 ... 2.5 mm²","Response Delay Maximum":"1 s","Width Of The Enclosure":"42 mm","Height Of The Enclosure":"125 mm","Voltage Curve At Output":"Controlled, isolated DC voltage","For Emitted Interference":"EN 55022 Class B","Nippon Kaiji Kyokai (NK)":"No","Type Of Signal At Output":"Relay contact (NO contact, rating 60 V DC/ 0.3 A) for \"24 V OK\"","Adjustable Output Voltage":"24 ... 28.8 V","For Interference Immunity":"EN 61000-6-2","Load Step 10 To 90% Typical":"0.2 ms","Load Step 90 To 10% Typical":"0.2 ms","cCSAus, Class 1, Division 2":"No","Load Step 100 To 50% Typical":"0.2 ms","Load Step 50 To 100% Typical":"0.2 ms","at rated input voltage 120 V":"2.5 A","at rated input voltage 230 V":"1.4 A","Supplied Active Power Typical":"120 W","Type Of Electrical Connection":"screw-type terminals","at output 1 at DC rated value":"24 V","For Mains Harmonics Limitation":"EN 61000-3-2","Type Of Output Voltage Setting":"via potentiometer; max. 120 W","Design Of Input Wide Range Input":"Yes","During NO-Load Operation Maximum":"1 W","Type Of The Power Supply Network":"1-phase AC or DC","output voltage at DC rated value":"24 V","Lloyds Register of Shipping (LRS)":"No","Design Of Short-Circuit Protection":"Shutdown and periodic restart attempts","On Slow Fluctuation Of Ohm Loading":"0.2 %","Operating Resource Protection Class":"Class I","Design Of The Overvoltage Protection":"< 32 V","Display Version For Normal Operation":"Green LED for 24 V OK","On Slow Fluctuation Of Input Voltage":"0.1 %","environmental category acc. to IEC 60721":"Climate class 3K3, 5 … 95% no condensation","French marine classification society (BV)":"No","Relative Overall Tolerance Of The Voltage":"3 %","Response Value Current Limitation Typical":"6 A","Operating Condition Of The Mains Buffering":"at Vin = 230 V","Product Function Output Voltage Adjustable":"Yes","Property Of The Output Short-Circuit Proof":"Yes","Galvanic Isolation Between Input And Output":"Yes","American Bureau of Shipping Europe Ltd. (ABS)":"No","On Short-Circuiting During The Start-Up Typical":"6 A","Behavior Of The Output Voltage When Switching On":"No overshoot of Vout (soft start)","current limitation of inrush current at 25 °C maximum":"36 A","Product Feature Of The Enclosure Housing Can Be Lined Up":"Yes","At Rated Output Voltage For Rated Value Of The Output Current Typical":"15 W","Buffering Time For Rated Value Of The Output Current In The Event Of Power Failure Minimum":"30 ms","Relative Control Precision Of The Output Voltage With Rapid Fluctuation Of The Input Voltage By +/- 15% Typical":"0.1 %"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2239a6049752366729b6e0b0dce0691a.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=766298&mlfb=6EP4333-0SB00-0AY0"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6EP4333-0SB00-0AY0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6EP4333-0SB00-0AY0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}