{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7132-0BH11-0XB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7132-0BH11-0XB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7132-0BH11-0XB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7132-0BH11-0XB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens ET 200S digital output module, 6ES7132-0BH11-0XB0, 16 DO, 24 V DC, 2 A per group of 4, PROFIBUS DP, 235 x 130 x 60 mm.","salesMarkdown":"## 16 digital outputs at 2 A per group — the current-limiting factor The 6ES7132-0BH11-0XB0: This ET 200S module packs 16 digital outputs into a single 235 mm-wide slice, each output rated 24 V DC and grouped in fours at 2 A per group. The grouping means the total load across any set of four channels cannot exceed 2 A — the per-channel limit is effectively 0.5 A if all four are on simultaneously, though the module can deliver 2 A to a single channel within the group. The 7 W max power loss tells you the thermal budget: at full load, that 7 W is dissipated inside the enclosure, so adjacent modules need breathing room. ## PROFIBUS DP at 12 Mbit/s — bus timing matters The module communicates over PROFIBUS DP at up to 12 Mbit/s, with bus fault and RUN LEDs on the front for quick signal-integrity checks. Unshielded cable runs are good to 100 m — beyond that, or in a VFD-heavy panel, you'll want shielded PROFIBUS cable to keep the bus error rate down. The electronic short-circuit protection per channel means a faulted output drops out without taking the whole group or the backplane bus down.","metaTitle":"Siemens 6ES7132-0BH11-0XB0 Digital Output Module, 16 DO","metaDescription":"Siemens 6ES7132-0BH11-0XB0 ET 200S digital output module, 16 outputs, 24 V DC, 2 A per group of 4, PROFIBUS DP. Active lifecycle, available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Digital Output Modules"],"specifications":{"I2t":"0.05 A²·s; with starting current inrush","Depth":"60 mm; EB and TB","Width":"235 mm; EB and TB","Height":"130 mm; EB and TB","RUN LED":"Yes","Operation, max.":"95 %; RH class 2 in accordance with IEC 1131-2","Operation, min.":"15 %","SYNC capability":"Yes","Weight, approx.":"900 g; EB and TB","lifecycle_stage":"current","Power loss, max.":"7 W","Rated value (DC)":"24 V","Unshielded, Max.":"100 m","Bus fault BF (red)":"Yes","On Lamp Load, Max.":"8 Hz","up to 60 °C, max.":"4 A","For Signal \"0\", Max.":"2 V; idling","For Signal \"1\", Min.":"UE -3 V","Usable terminal block":"TB2/DC, TB2-4/DC, TB4/DC, TB4-4/DC","Transmission rate, max.":"12 Mbit/s","Short-circuit protection":"Yes; Electronic","Current consumption, typ.":"100 mA; From L5+; logic","Number of digital outputs":"16","With Inductive Load, Max.":"0.5 Hz","With Resistive Load, Max.":"100 Hz","Controlling a digital input":"Yes","Horizontal Installation, Max.":"60 °C; 40°C for other mountings","Horizontal Installation, Min.":"0 °C","Permissible Range, Lower Limit":"795 hPa","Permissible Range, Upper Limit":"1 080 hPa","Between The Channels, In Groups Of":"4","Bus protocol/transmission protocol":"PROFIBUS DP","tested according to IEC 60068-2-27":"Yes; IEC 68, Part 2-27; half-sine, 15 g, 11 ms","permissible range, lower limit (DC)":"18.5 V","permissible range, upper limit (DC)":"30.2 V","Potential separation digital outputs":"Yes","For Signal \"0\" Residual Current, Max.":"1 mA","For Signal \"1\" Permissible Range, Max.":"2 A; in groups of 4","Status indicator digital output (green)":"Yes","between electronic block and PROFIBUS DP":"Yes","Limitation of inductive shutdown voltage to":"typ. (L1+ to L4+) -50 V","Operation, tested according to IEC 60068-2-6":"Yes; IEC 68, Part 2-6; 10 to 57 Hz; (constant amplitude 0.075 mm); 57 to 150 Hz; (constant acceleration 1 g)","Design of electrical connection for the inputs and outputs":"Screw-type and spring-loaded terminals, permanent wiring; 3 and 4-wire connection"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$749.30","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e5444c2a6d45e12e1a825e1259ff12c7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=343866&mlfb=6ES7132-0BH11-0XB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7132-0BH11-0XB0/alternatives.json"},"ai":{"faq":[{"question":"What is the I2t rating of 6ES7132-0BH11-0XB0?","answer":"The listed I2t value is 0.05 A²·s, with starting current inrush considered. This is the let-through energy the module can handle during a short-circuit event before the electronic protection trips."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7132-0BH11-0XB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7132-0BH11-0XB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}