{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7132-4HB50-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7132-4HB50-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7132-4HB50-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7132-4HB50-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC DP ET 200S electronics module, 6ES7132-4HB50-0AB0, 2 DQ relay outputs (change-over contact), 5 A rated, 15 mm width, 24 V DC from backplane.","salesMarkdown":"The Siemens 6ES7132-4HB50-0AB0 is a SIMATIC DP ET 200S electronics module providing two relay digital outputs (change-over contacts) rated at 5 A for both 24 V–48 V DC and 24 V–230 V AC loads. It draws power from the backplane bus at 24 V DC, so no separate load supply is needed for the relay coil. At just 15 mm wide and 52 mm deep, this module fits tightly into a crowded ET 200S terminal strip — useful when you're packing relay outputs into a small panel footprint. The 5 A continuous thermal current per channel handles moderate loads like contactor coils, small motors, or indicator lamps, but note there is no built-in short-circuit protection, so external fusing or a miniature circuit breaker is expected on each output circuit. The module supports substitute-value output on CPU stop — you can configure it to either hold the last value or force a 0/1 state, which is helpful for fail-safe plant behavior. It also includes reverse-polarity protection and galvanic isolation between channels and the backplane bus. ## Integration Notes This module occupies one ET 200S terminal slot (15 mm) and connects via the backplane bus. The relay outputs are change-over contacts — verify your wiring matches the form-C configuration. Maximum unshielded cable length is 600 m; shielded runs can go to 1000 m. Switching frequency is limited to 2 Hz on resistive or lamp loads, and 0.5 Hz on inductive loads — fine for on/off control, not for high-speed cycling. No diagnostics function is built in, so fault detection relies on the external circuit or a higher-level diagnostic block. The module does provide a green status LED per channel for quick visual check.","metaTitle":"Siemens 6ES7132-4HB50-0AB0 SIMATIC DP ET 200S 2 DQ Relay Mod","metaDescription":"Siemens 6ES7132-4HB50-0AB0 SIMATIC DP ET 200S electronics module with 2 relay outputs, 5 A rated, 15 mm wide, 24 V DC from backplane. Active lifecycle, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Digital Output Modules"],"specifications":{"Depth":"52 mm","Width":"15 mm","title":"6ES7132-4HB50-0AB0","Height":"81 mm","description":"*** Spare part *** SIMATIC DP, Electronics module ET 200S: 2 DQ relay (change-over contact) 24 V-48 V DC/5 A, 24 V-230 V AC/5 A, 15 mm width, substitute value output, with manual operation","With Packing":"2 bit","Shielded, Max.":"1 000 m","Weight, approx.":"50 g","lifecycle_stage":"current","Power loss, typ.":"0.6 W","Rated value (DC)":"24 V; From power module","Unshielded, Max.":"600 m","On Lamp Load, Max.":"2 Hz","Between The Channels":"Yes","Diagnostics function":"No","Type of digital output":"Relays","Short-circuit protection":"No","Number of digital outputs":"2","With Inductive Load, Max.":"0.5 Hz","With Resistive Load, Max.":"2 Hz","For Signal \"1\" Rated Value":"5 A","Controlling a digital input":"Yes","Response to CPU/master STOP":"Substitute a value/keep last value","Reverse polarity protection":"Yes","Substitute values connectable":"Yes; 0/1","Address space per module, max.":"1 byte","Thermal continuous current, max.":"5 A","from backplane bus 3.3 V DC, max.":"10 mA","For Signal \"1\" Minimum Load Current":"8 mA","Between The Channels And Backplane Bus":"Yes","Status indicator digital output (green)":"Yes","Between the channels and load voltage L+":"Yes","from load voltage L+ (without load), max.":"30 mA","Limitation of inductive shutdown voltage to":"No","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$78.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e5444c2a6d45e12e1a825e1259ff12c7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=177079&mlfb=6ES7132-4HB50-0AB0"},"ai":{"faq":[{"question":"What are the key ratings of this module?","answer":"It has 2 relay outputs (change-over contacts) rated at 5 A for 24 V–48 V DC and 24 V–230 V AC loads. Width is 15 mm, depth 52 mm. Power comes from the backplane bus at 24 V DC. No short-circuit protection is built in."},{"question":"What is the switching frequency for inductive loads?","answer":"Maximum 0.5 Hz with inductive load, and 2 Hz with resistive or lamp load."},{"question":"Does this module support substitute values on CPU stop?","answer":"Yes, it can be configured to substitute a value (0 or 1) or keep the last value when the CPU stops."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7132-4HB50-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7132-4HB50-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}