{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7132-6BF00-2BA0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7132-6BF00-2BA0","canonicalUrl":"https://aoctrl.com/siemens/6ES7132-6BF00-2BA0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7132-6BF00-2BA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC ET 200SP, 6ES7132-6BF00-2BA0, digital output module (DQ Yes), 24 V DC, 4 A max per channel at 60 °C, 15 mm width, 28 g.","salesMarkdown":"Siemens SIMATIC ET 200SP, 6ES7132-6BF00-2BA0, digital output module (DQ Yes), 24 V DC, 4 A max per channel at 60 °C, 15 mm width, 28 g.","metaTitle":"Siemens 6ES7132-6BF00-2BA0 ET 200SP DQ Module, 4A","metaDescription":"Active production. 24V DC digital output, 4A/ch at 60°C, 15mm wide, short-circuit & wire-break diagnostics. SIL 2. Source to order, friend price for quantity.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Digital Output Modules"],"specifications":{"DQ":"Yes","MSO":"No","PWM":"No","Depth":"58 mm","Width":"15 mm","Height":"73 mm","I&M data":"Yes; I&M0 to I&M3","Wire-break":"Yes; Module-wise","Group error":"Yes","Lower Limit":"48 Ω","Upper Limit":"12 kΩ","For Uprating":"No","Oversampling":"No","Short-circuit":"Yes; Module-wise","Shielded, Max.":"1 000 m","Current-sinking":"No","Weight, approx.":"28 g","lifecycle_stage":"current","\"0\" To \"1\", Max.":"50 µs; at rated load","\"1\" To \"0\", Max.":"100 µs; at rated load","Current-sourcing":"Yes","Diagnostic alarm":"Yes","Firmware version":"V1.1","Isochronous mode":"No","Power loss, typ.":"1 W","Rated value (DC)":"24 V","Unshielded, Max.":"600 m","usable BaseUnits":"BU type A0","1-Wire Connection":"BU type A0","2-Wire Connection":"BU type A0","3-Wire Connection":"BU type A0 with AUX terminals or potential distributor module","4-Wire Connection":"BU type A0 + Potential isolation module","FW update possible":"Yes","On Lamp Load, Max.":"10 Hz","up to 60 °C, max.":"4 A","Between The Channels":"No","Diagnostics function":"Yes","Isolation tested with":"707 V DC (type test)","Redundancy capability":"Yes","SIL acc. to IEC 61508":"SIL 2","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; green/red DIAG LED","Type of digital output":"Source output (PNP, current-sourcing)","For Channel Diagnostics":"No","Current per module, max.":"4 A","Response threshold, typ.":"0.7 to 1.3 A","Short-circuit protection":"Yes","Current consumption, max.":"35 mA; without load","Current per channel, max.":"0.5 A","Mechanical coding element":"Yes","Number of digital outputs":"8","With Inductive Load, Max.":"2 Hz","With Resistive Load, Max.":"100 Hz","For Signal \"1\" Rated Value":"0.5 A","Controlling a digital input":"Yes","Reverse polarity protection":"Yes","Vertical Installation, Max.":"50 °C; in all other mounting positions","Vertical Installation, Min.":"0 °C; in all other mounting positions","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"0 °C","Monitoring the supply voltage":"Yes","Substitute values connectable":"Yes","Suitable for safety functions":"No","Address space per module, max.":"1 byte; + 1 byte for QI information","DQ with energy-saving function":"No","For Redundant Control Of A Load":"Yes","Digital outputs, parameterizable":"Yes","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","For Signal \"0\" Residual Current, Max.":"0.1 mA","Between The Channels And Backplane Bus":"Yes","PROFIBUS from GSD version/GSD revision":"GSD Revision 5","PROFINET from GSD version/GSD revision":"GSDML V2.3","Monitoring of the supply voltage (PWR-LED)":"Yes; green PWR LED","Performance level according to ISO 13849-1":"PL d","Limitation of inductive shutdown voltage to":"Typ. L+ (-50 V)","STEP 7 configurable/integrated from version":"V5.5 SP3 / -","Ambient air temperature-barometric pressure-altitude":"On request: Ambient temperatures lower than 0 °C (without condensation) and/or installation altitudes greater than 2 000 m","STEP 7 TIA Portal configurable/integrated from version":"V11 SP2 / V13","Suitable for safety-related tripping of standard modules":"Yes; From FS03","Color code for module-specific color identification plate":"CC02","Between The Channels And The Power Supply Of The Electronics":"No"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$133.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e5444c2a6d45e12e1a825e1259ff12c7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=571029&mlfb=6ES7132-6BF00-2BA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7132-6BF00-2BA0/alternatives.json"},"ai":{"faq":[{"question":"Can this module replace the 6ES7522-1BH01-0AB0 in an S7-1500 rack?","answer":"No—the 6ES7132-6BF00-2BA0 is built for the ET 200SP system (15 mm backplane, BU type A0) while the 6ES7522-1BH01-0AB0 mounts in the S7-1500 rack. They are not mechanically or electrically interchangeable. If your rack is ET 200SP, this module is the correct choice."},{"question":"Does the module have diagnostics for wire break or short circuit?","answer":"Yes—module-wise diagnostics for wire break (load resistance outside 48 Ω to 12 kΩ range) and short-circuit. It also supports a diagnostic alarm and group error indication. No channel-to-channel isolation, though."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7132-6BF00-2BA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7132-6BF00-2BA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}