{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7132-6BF01-0BA0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7132-6BF01-0BA0","canonicalUrl":"https://aoctrl.com/siemens/6ES7132-6BF01-0BA0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7132-6BF01-0BA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC ET 200SP digital output module, DQ 4x24VDC/2A, 6ES7132-6BF01-0BA0, 15 mm width, 4 A per channel up to 60 °C, with diagnostics.","salesMarkdown":"The Siemens 6ES7132-6BF01-0BA0 is a SIMATIC ET 200SP digital output module with four channels, each rated for 24 VDC and capable of 2 A per channel. It delivers 4 A total per module up to 60 °C ambient, so it handles grouped solenoid or contactor loads without derating in a warm cabinet. The 15 mm width keeps DIN-rail density high — you can pack more I/O per row than wider blocks. This is a current-production part (lifecycle status: current), so it's still a standard BOM line for new panels and spares. No end-of-life notice to track yet. Each channel switches from 0 to 1 in 50 µs at rated load and 1 to 0 in 100 µs. That's fast enough for valve banks and indicator lamps, but not for high-speed camming or PWM — this module has no PWM or oversampling capability. If you need pulse trains, look at a technology module instead. The module draws 1 W typical from the backplane bus. In a dense ET 200SP station with a dozen output modules, that adds up — keep an eye on the total power budget of the interface module. Diagnostics cover wire-break, short-circuit to L+ and to M, and group errors — all reported module-wise. When a valve drops out mid-shift, the diagnostic alarm tells you which module, not which channel, so you still need to trace the individual output. The lamp load switching limit is 10 Hz max, fine for indicator lights but not for strobes. ## Mounting and wiring — what fits The module snaps onto a BU type A0 BaseUnit. For 3-wire sensors you need the AUX terminals on the BaseUnit or a separate potential distributor module; for 4-wire devices you add the potential distributor. That's a few extra parts to order alongside the module — factor them into the BOM. Dimensions are 15 mm wide, 73 mm high, 58 mm deep. It fits standard ET 200SP DIN-rail assemblies. Unshielded cable runs up to 600 m; shielded up to 1000 m — plenty for distributed I/O in a plant. Automatic encoding means the module ID is read by the interface module on power-up — no DIP switches to set. I&M data (I&M0 to I&M3) lets you tag the module with location and installation date for asset tracking.","metaTitle":"Siemens 6ES7132-6BF01-0BA0 DQ Module, 4A, 24 VDC, 15 mm","metaDescription":"Siemens 6ES7132-6BF01-0BA0 digital output module, 4 A per channel at up to 60 °C, 24 VDC, 15 mm wide. Active lifecycle, sourced to order. Request RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Digital Output Modules"],"specifications":{"DQ":"Yes","MSO":"No","PWM":"No","Depth":"58 mm","Width":"15 mm","Height":"73 mm","I&M data":"Yes; I&M0 to I&M3","Wire-break":"Yes; Module-wise","Group error":"Yes","Lower Limit":"48 Ω","Upper Limit":"12 kΩ","For Uprating":"No","Oversampling":"No","Shielded, Max.":"1 000 m","Weight, approx.":"30 g","lifecycle_stage":"current","\"0\" To \"1\", Max.":"50 µs; at rated load","\"1\" To \"0\", Max.":"100 µs; at rated load","Current-sourcing":"Yes","Diagnostic alarm":"Yes","Firmware version":"V0.0","Isochronous mode":"No","Power loss, typ.":"1 W","Rated value (DC)":"24 V","Unshielded, Max.":"600 m","usable BaseUnits":"BU type A0","1-Wire Connection":"BU type A0","2-Wire Connection":"BU type A0","3-Wire Connection":"BU type A0 with AUX terminals or potential distributor module","4-Wire Connection":"BU type A0 + Potential distributor module","Automatic encoding":"Yes","FW update possible":"No","On Lamp Load, Max.":"10 Hz","Short-circuit to M":"Yes; Module-wise","up to 50 °C, max.":"4 A","up to 60 °C, max.":"4 A","Short-circuit to L+":"Yes; Module-wise","Between The Channels":"No","Diagnostics function":"Yes","For Signal \"1\", Min.":"L+ (-0.8 V)","HW functional status":"From FS02","Isolation tested with":"707 V DC (type test)","SIL acc. to IEC 61508":"SIL 2","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; green/red DIAG LED","Type of digital output":"Source output (PNP, current-sourcing)","For Channel Diagnostics":"No","Current per module, max.":"4 A","Response threshold, typ.":"1 A","Short-circuit protection":"Yes","Current consumption, max.":"35 mA; without load","Current per channel, max.":"0.5 A","Mechanical coding element":"Yes","Number of digital outputs":"8","With Inductive Load, Max.":"2 Hz","With Resistive Load, Max.":"100 Hz","For Signal \"1\" Rated Value":"0.5 A","Controlling a digital input":"Yes","Reverse polarity protection":"Yes","Vertical Installation, Max.":"50 °C","Vertical Installation, Min.":"-30 °C; < 0 °C as of FS02","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"-30 °C; < 0 °C as of FS02","Monitoring the supply voltage":"Yes","Substitute values connectable":"Yes","Suitable for safety functions":"No","Address space per module, max.":"1 byte; + 1 byte for QI information","DQ with energy-saving function":"No","For Redundant Control Of A Load":"Yes","Digital outputs, parameterizable":"Yes","Type of mechanical coding element":"Type A","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","For Signal \"0\" Residual Current, Max.":"0.1 mA","Between The Channels And Backplane Bus":"Yes","For Signal \"1\" Permissible Range, Max.":"0.5 A","PROFIBUS from GSD version/GSD revision":"One GSD file each, Revision 3 and 5 and higher","PROFINET from GSD version/GSD revision":"GSDML V2.3","Monitoring of the supply voltage (PWR-LED)":"Yes; green PWR LED","PCS 7 configurable/integrated from version":"V8.1 SP1","Performance level according to ISO 13849-1":"PL d","Installation altitude above sea level, max.":"5 000 m; Restrictions for installation altitudes > 2 000 m, see manual","Limitation of inductive shutdown voltage to":"Typ. L+ (-50 V)","STEP 7 configurable/integrated from version":"V5.5 SP3 or higher","STEP 7 TIA Portal configurable/integrated from version":"V14","Suitable for safety-related tripping of standard modules":"Yes; see FAQ Entry ID: 39198632","Color code for module-specific color identification plate":"CC02","Between The Channels And The Power Supply Of The Electronics":"No"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$43.18","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7e14e5acbb919a9179544adacfddaf38.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1075395&mlfb=6ES7132-6BF01-0BA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7132-6BF01-0BA0/alternatives.json"},"ai":{"faq":[{"question":"What is the current rating per channel and at what temperature?","answer":"Each channel is rated 2 A at 24 VDC, and the module delivers 4 A total up to 60 °C ambient. No derating is needed within that range."},{"question":"Where can I buy 6ES7132-6BF01-0BA0 and get a price?","answer":"This module is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit a request and we'll get you numbers."},{"question":"Does this module support PWM or oversampling?","answer":"No. The module has no PWM and no oversampling capability. It is a standard on/off digital output, not suited for pulse-train or high-speed camming applications."},{"question":"What diagnostics does the module report?","answer":"It reports wire-break, short-circuit to L+ and to M, and group errors — all module-wise. A diagnostic alarm is generated on fault, but you'll need to trace the specific channel yourself."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7132-6BF01-0BA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7132-6BF01-0BA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}