{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7132-7HB00-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7132-7HB00-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7132-7HB00-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7132-7HB00-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC DP electronic module for ET200iSP, 6ES7132-7HB00-0AB0, 2 relay outputs UC60V/2A, Ex eb ib mb IIC T4 Gb, 136.5 mm depth.","salesMarkdown":"## Relay outputs at 2 A in an Ex-rated module The 6ES7132-7HB00-0AB0 is a SIMATIC DP electronic module for the ET200iSP remote I/O system, carrying two relay outputs rated 2 A per channel at up to 60 V UC (UC60V / 2A). The relay type means the output is galvanically isolated from the backplane bus — useful when switching different voltage potentials on adjacent channels without commoning the returns. This module carries Ex certification eb ib mb IIC T4 Gb (gas) and eb ib mb I Mb (mining). ## Switching speeds and diagnostic coverage The relay switches from 0 to 1 in 8 ms max and from 1 to 0 in 3 ms max — fast enough for valve and contactor control in batch processes, but not for high-speed counting or pulse trains. Maximum switching frequency is 0.5 Hz with resistive load and 0.2 Hz with inductive load; above that the relay contacts risk weld or reduced life. A diagnostic alarm is generated on channel faults (wire-break or short-circuit cannot be detected in the contact power circuit, per the spec — the relay simply reports whether the coil is energised). The module also supports substitute values and readable diagnostic information, which helps the PLC logic decide what to do when a channel faults. Power consumption is 1.1 W typ, drawing 100 mA from the backplane bus plus up to 120 mA from the load voltage L+ (without load). The thermal continuous current matches the rated 2 A per channel, derated per the manual above 60 °C ambient. The module is the standard relay-output variant for the ET200iSP system.","metaTitle":"Siemens 6ES7132-7HB00-0AB0 SIMATIC DP, 2 Relay Outputs, Ex","metaDescription":"Siemens 6ES7132-7HB00-0AB0 SIMATIC DP electronic module for ET200iSP. 2 relay outputs, UC60V/2A, Ex eb ib mb IIC T4 Gb. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Digital Output Modules"],"specifications":{"Depth":"136.5 mm","Width":"30 mm","title":"6ES7132-7HB00-0AB0","Height":"129 mm","CE mark":"Yes","Wire-break":"No; Cannot be determined in contact power circuit","description":"SIMATIC DP, electronic module for ET200iSP, 2DO relay UC60V / 2A, Ex eb ib mb IIC T4 Gb, Ex eb ib mb I Mb","For Uprating":"No","Short-circuit":"No; Cannot be determined in contact power circuit","Shielded, Max.":"500 m","Weight, approx.":"255 g","lifecycle_stage":"current","\"0\" To \"1\", Max.":"8 ms","\"1\" To \"0\", Max.":"3 ms","Diagnostic alarm":"Yes","Power loss, typ.":"1.1 W","Unshielded, Max.":"500 m","Hardware interrupt":"No","Between The Channels":"Yes","Group error SF (red)":"Yes","SIL acc. to IEC 61508":"No","Type of digital output":"Relays","Short-circuit protection":"No","Current consumption, typ.":"100 mA","Number of digital outputs":"2","With Inductive Load, Max.":"0.2 Hz; See data in manual","With Resistive Load, Max.":"0.5 Hz; See data in manual","For Signal \"1\" Rated Value":"2 A","Uo (no-load voltage), max.":"60 V","Substitute values connectable":"Yes","Diagnostic information readable":"Yes","For Redundant Control Of A Load":"No","Thermal continuous current, max.":"2 A; See data in manual","Between The Channels And Backplane Bus":"Yes","Status indicator digital output (green)":"Yes; Per channel","with resistive load, up to 60 °C, max.":"2 A; See data in manual","Between the channels and load voltage L+":"Yes; Channels and power bus","from load voltage L+ (without load), max.":"120 mA","Um (voltage at non-intrinsically safe connecting terminals), max.":"250 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$255.27 – $519.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e5444c2a6d45e12e1a825e1259ff12c7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=63328&mlfb=6ES7132-7HB00-0AB0"},"ai":{"faq":[{"question":"Does 6ES7132-7HB00-0AB0 have diagnostic alarm?","answer":"Yes, the module generates a diagnostic alarm on channel faults. Wire-break and short-circuit cannot be detected in the contact power circuit, but the relay coil status and other diagnostics are readable."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7132-7HB00-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7132-7HB00-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}