{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7134-0KH01-0XB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7134-0KH01-0XB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7134-0KH01-0XB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7134-0KH01-0XB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens ET 200S analog input module, 6ES7134-0KH01-0XB0, 8-channel RTD/TC, 24 VDC, 60 x 160 x 130 mm (EB/TB).","salesMarkdown":"## What this module handles on the line The Siemens 6ES7134-0KH01-0XB0 is an 8-channel analog input module for the ET 200S distributed I/O system. It accepts RTDs (Pt100, Ni100) and thermocouples (Types E, J, K, L, N, R, T, U), converting them to digital values for the backplane bus. The integrating voltage/time conversion measurement principle rejects noise on long field runs — shielded cable up to 100 m is specified. ## Supply and power budget Rated 24 VDC supply with a 35 V surge tolerance for transients under 0.5 s. Typical power loss is 2 W — no forced cooling needed in a standard IP20 enclosure, but account for the heat in a densely packed cabinet near the kiln or preheater. ## Diagnostics you can use Parameterizable diagnostic alarm and a limit value alarm on channels 0 and 2. The RUN LED and bus fault BF (red) LED give on-card status without reaching for a programming device. Overrange detection is built in — useful for catching a broken thermocouple before it drifts the process.","metaTitle":"Siemens 6ES7134-0KH01-0XB0 Analog Input Module, RTD/TC","metaDescription":"Siemens 6ES7134-0KH01-0XB0 analog input module for ET 200S. Supports Pt100, Ni100, thermocouples Types E, J, K, L, N, R, T, U. 24 VDC supply, 2 W typ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLC Communication Modules"],"specifications":{"Depth":"60 mm; EB and TB","Width":"160 mm; EB and TB","title":"6ES7134-0KH01-0XB0","Height":"130 mm; EB and TB","Ni 100":"Yes","Pt 100":"Yes","Type E":"Yes","Type J":"Yes","Type K":"Yes","Type L":"Yes","Type N":"Yes","Type R":"Yes","Type T":"Yes","Type U":"Yes","RUN LED":"Yes","Voltage":"Yes","Overrange":"Yes; Overrange","Resistance":"Yes","description":"*** SPARE PART*** SIMATIC DP, ELECTRONIC MODULE ANALOG, FOR ET 200B, W=160MM, 8AI (THERMOCOUPLES) OR 4AI (PT100); 12 BIT","-1 V to +1 V":"Yes","0 To 48 Ohms":"Yes","Thermocouple":"Yes","0 To 150 Ohms":"Yes","0 To 300 Ohms":"Yes","0 To 600 Ohms":"Yes","Shielded, Max.":"100 m","Operation, max.":"95 %; RH class 2 in accordance with IEC 1131-2","Operation, min.":"15 %","Parameterizable":"Yes","Weight, approx.":"550 g; EB and TB","lifecycle_stage":"current","-80 mV to +80 mV":"Yes","Diagnostic alarm":"Yes; Parameterizable","Power loss, typ.":"2 W","Rated value (DC)":"24 V; Value at t < 0.5 s: 35 V","For Thermocouples":"Type E, J, K, L, N, T, U","Limit value alarm":"Yes; Parameterizable, channels 0 and 2","-250 mV to +250 mV":"Yes","-500 mV to +500 mV":"Yes","Bus fault BF (red)":"Yes","Measurement principle":"Integrating voltage/time conversion","Usable terminal block":"TB8","Resistance thermometer":"Yes","For Voltage Measurement":"Yes","Number of analog inputs":"8; 8 voltage inputs/thermocouples or 4 Pt100, Ni100","Transmission rate, max.":"12 Mbit/s","between the inputs (UCM)":"max. ±1 V","Current consumption, typ.":"80 mA; Logic","For Resistance Thermometer":"Pt100 (standard), Ni100 (standard)","Horizontal Installation, Max.":"60 °C; 40°C for other mountings","Horizontal Installation, Min.":"0 °C","Common mode interference, min.":"70 dB; Upp < 3 V","Permissible Range, Lower Limit":"795 hPa","Permissible Range, Upper Limit":"1 080 hPa","Input resistance (-1 V to +1 V)":"10 Ω","Between the inputs and MANA (UCM)":"max. ±1 V","Integration time, parameterizable":"Yes; 2,5 / 16,67 / 20 / 100 ms","Bus protocol/transmission protocol":"PROFIBUS DP","Crosstalk between the inputs, min.":"50 dB; At 50/60 Hz","Potential separation analog inputs":"No","tested according to IEC 60068-2-27":"Yes; IEC 68, Part 2-27; half-sine, 15 g, 11 ms","Input resistance (-80 mV to +80 mV)":"10 Ω","permissible range, lower limit (DC)":"18.5 V","permissible range, upper limit (DC)":"30.2 V","Input resistance (-250 mV to +250 mV)":"10 Ω","Input resistance (-500 mV to +500 mV)":"10 Ω","Wire-break in signal transmitter cable":"Yes; For Pt 100, Ni 100, R, ±80 mV, thermocouples type E, J, K, L, N, T, U (parameterizable)","Voltage, relative to input range, (+/-)":"0.6 %; At 80 mV; ±0.4 % from 250 to 1 000 mV","between electronic block and PROFIBUS DP":"Yes","Resistance, relative to input range, (+/-)":"0.6 %","Operation, tested according to IEC 60068-2-6":"Yes; IEC 68, Part 2-6; 10 to 57 Hz; (constant amplitude 0.075 mm); 57 to 150 Hz; (constant acceleration 1 g)","Linearity error (relative to input range), (+/-)":"0.05 %","Temperature error (relative to input range), (+/-)":"0.005 %/K","For Resistance Measurement With Two-Wire Connection":"Yes","Additional Conversion Time For Wire-Break Monitoring":"10 / 10 / 10 / 10 ms","For Resistance Measurement With Four-Wire Connection":"Yes","Resolution with overrange (bit including sign), max.":"12 bit; Two's complement","Basic conversion time, including integration time (ms)":"8 / 35 / 42 / 200","Design of electrical connection for the inputs and outputs":"Screw-type and spring-loaded terminals, permanent wiring; 3 and 4-wire connection","Interference voltage suppression for interference frequency f1 in Hz":"400 / 60 / 50 / 10 Hz","Permissible Input Voltage For Voltage Input (Destruction Limit), Max.":"32 V","Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)":"0.05 %","Series mode interference (peak value of interference < rated value of input range), min.":"40 dB"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$2,822.07","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e5444c2a6d45e12e1a825e1259ff12c7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=459610&mlfb=6ES7134-0KH01-0XB0"},"ai":{"faq":[{"question":"What thermocouple types does 6ES7134-0KH01-0XB0 support?","answer":"It supports Types E, J, K, L, N, R, T, and U. It also handles Pt100 and Ni100 RTDs, plus millivolt ranges from -80 mV to +500 mV and resistance ranges from 0 to 600 ohms."},{"question":"Where can I buy 6ES7134-0KH01-0XB0?","answer":"This module is sourced through independent distribution."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7134-0KH01-0XB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7134-0KH01-0XB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}