{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7134-4FB00-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7134-4FB00-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7134-4FB00-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7134-4FB00-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens ET 200S analog input module · 6ES7134-4FB00-0AB0 · 2 AI, ±5 V / 1-5 V / ±10 V · integrating measurement · wire-break diagnostics (1-5 V) · 15 mm wide · current production.","salesMarkdown":"The 6ES7134-4FB00-0AB0 is a Siemens ET 200S 2-channel analog input module for voltage signals. It measures ±5 V, 1 to 5 V, or ±10 V using an integrating measurement principle, and each channel is parameterizable for digital filtering in four stages. Rated voltage of 24 V DC is supplied from the backplane bus; power loss is 0.6 W typical. The module is 15 mm wide, 81 mm high, and 52 mm deep, fitting a single ET 200S slot. Conversion time per channel is 65 ms (55/65 ms variants), and integration time is parameterizable at 16,7 or 20 ms. Isolation is tested at 500 V DC between channels and backplane bus. ## Signal integrity and diagnostics For clean signals in a noisy plant, each channel requires shielded cable; maximum cable run is 200 m. Wire-break detection is enabled only in the 1 to 5 V range. Group diagnostics (SF red LED) and per-channel overflow/underflow can be enabled or disabled. No isochronous mode (no equidistant cycle), so the module suits standard ET 200S applications rather than synchronized motion.","metaTitle":"Siemens 6ES7134-4FB00-0AB0 Analog Input Module, 2 AI, ±10 V","metaDescription":"Siemens 6ES7134-4FB00-0AB0 ET 200S analog input module, 2 AI, voltage ranges ±10 V/1-5 V/±5 V, integrating measurement, wire-break diag, active production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Analog Input Modules"],"specifications":{"Depth":"52 mm","Width":"15 mm","Height":"81 mm","Remark":"4 byte","Step: low":"Yes; 4x cycle time","1 V to 5 V":"Yes","Step: High":"Yes; 64x cycle time","Step: None":"Yes; 1x cycle time","Wire-break":"Yes; Measuring range 1 to 5 V only","Group error":"Yes","-5 V to +5 V":"Yes","Step: Medium":"Yes; 32x cycle time","-10 V to +10 V":"Yes","Shielded, Max.":"200 m","Parameterizable":"Yes; In four stages by means of digital filtering","Weight, approx.":"40 g","lifecycle_stage":"current","Isochronous mode":"No","Power loss, typ.":"0.6 W","Rated value (DC)":"24 V; From power module","Group diagnostics":"Disable / enable","Overflow/underflow":"Disable / enable","Between The Channels":"No","Group error SF (red)":"Yes","Integration time (ms)":"16,7 / 20 ms","Isolation tested with":"500 V DC","Measurement principle":"integrating","Diagnostics wire break":"Disable / enable (only in measuring range 1 to 5 V)","Measurement type/range":"deactivated / ±5 V / 1 to 5 V / ±10 V","Number of analog inputs":"2","Reverse polarity protection":"Yes","Conversion time (per channel)":"65 ms; 55 / 65 ms","Address space per module, max.":"4 byte","Cycle time (all channels) max.":"Number of active channels per module x basic conversion time","Integration time, parameterizable":"Yes","from backplane bus 3.3 V DC, max.":"10 mA","Between The Channels And Backplane Bus":"Yes","Voltage, relative to input range, (+/-)":"0.4 %","Between the channels and load voltage L+":"Yes","from load voltage L+ (without load), max.":"30 mA","Resolution with overrange (bit including sign), max.":"14 bit; ±10 V: 13 bit + sign, ±5 V: 13 bit + sign; 1 to 5 V: 13 bit","Interference voltage suppression for interference frequency f1 in Hz":"50 / 60 Hz","Permissible Input Voltage For Voltage Input (Destruction Limit), Max.":"35 V; 35 V continuous; 75 V for max. 1 ms (mark to space ratio 1:20)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$90.30 – $183.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e5444c2a6d45e12e1a825e1259ff12c7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=528372&mlfb=6ES7134-4FB00-0AB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7134-4FB00-0AB0/alternatives.json"},"ai":{"faq":[{"question":"What are the key specifications of this module?","answer":"It has 2 analog inputs for voltage ranges ±5 V / 1-5 V / ±10 V, integrating measurement, conversion time 65 ms per channel, wire-break diagnostics on 1-5 V range, power loss 0.6 W, dimensions 15 x 81 x 52 mm, and fits ET 200S distributed I/O."},{"question":"What is the maximum cable length for this analog input module?","answer":"Shielded cable can be run up to 200 m per channel."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7134-4FB00-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7134-4FB00-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}