{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7134-4FB01-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7134-4FB01-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7134-4FB01-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7134-4FB01-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens ET 200S analog input module, 6ES7134-4FB01-0AB0, 2 AI, 14-bit resolution, 24 V DC, 15 x 81 x 52 mm.","salesMarkdown":"The 6ES7134-4FB01-0AB0 is an ET 200S analog input module that snaps onto the DIN rail in a standard Siemens I/O rack. It draws its 24 V DC from the power module on the rail, not a separate supply, so the backplane bus handles the power distribution. At 15 mm wide, it fits into tight cabinet layouts — you can pack several of these next to each other without crowding the wireway. The shielded analog cable run is good for up to 200 m, which covers most field sensor runs in a plant. ## What the input specs mean on the line Two analog inputs, each configurable for ±10 V, ±5 V, or 1 to 5 V ranges, with a 14-bit resolution that gives you about 0.6 mV per step on the ±10 V range. That's enough resolution for most process signals — pressure transmitters, temperature transducers, flow meters — without needing a higher-count module. The conversion time is 65 ms per channel. The integration time is adjustable in four stages via digital filtering to smooth noisy signals. Wire-break detection works only in the 1 to 5 V range — if you're using a 4-20 mA shunt resistor, make sure the resulting voltage falls in that band or you lose the diagnostic. The module also flags overflow/underflow and a group error, which you can enable or disable per channel.","metaTitle":"Siemens 6ES7134-4FB01-0AB0 Analog Input Module, 2 AI, 14 bit","metaDescription":"Siemens 6ES7134-4FB01-0AB0 ET 200S analog input module with 2 inputs, 14-bit resolution, 24 V DC. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Analog Input Modules"],"specifications":{"Depth":"52 mm","Width":"15 mm","Height":"81 mm","Remark":"4 byte","Step: low":"Yes; 4x cycle time","1 V to 5 V":"Yes","Step: High":"Yes; 64x cycle time","Step: None":"Yes; 1x cycle time","Wire-break":"Yes; Measuring range 1 to 5 V only","Group error":"Yes","-5 V to +5 V":"Yes","Step: Medium":"Yes; 32x cycle time","-10 V to +10 V":"Yes","Shielded, Max.":"200 m","Parameterizable":"Yes; In four stages by means of digital filtering","Weight, approx.":"40 g","lifecycle_stage":"current","Isochronous mode":"No","Power loss, typ.":"0.6 W","Rated value (DC)":"24 V; From power module","Group diagnostics":"Disable / enable","Overflow/underflow":"Disable / enable","Between The Channels":"No","Group error SF (red)":"Yes","Integration time (ms)":"16,7 / 20 ms","Isolation tested with":"500 V DC","Measurement principle":"integrating","Diagnostics wire break":"Disable / enable (only in measuring range 1 to 5 V)","Number of analog inputs":"2","Reverse polarity protection":"Yes","Conversion time (per channel)":"65 ms; 55 / 65 ms","Address space per module, max.":"4 byte","Cycle time (all channels) max.":"Number of active channels per module x basic conversion time","Integration time, parameterizable":"Yes","from backplane bus 3.3 V DC, max.":"10 mA","Between The Channels And Backplane Bus":"Yes","Voltage, relative to input range, (+/-)":"0.4 %","Between the channels and load voltage L+":"Yes","from load voltage L+ (without load), max.":"30 mA","Resolution with overrange (bit including sign), max.":"14 bit; ±10 V: 13 bit + sign, ±5 V: 13 bit + sign; 1 to 5 V: 13 bit","Interference voltage suppression for interference frequency f1 in Hz":"50 / 60 Hz","Permissible Input Voltage For Voltage Input (Destruction Limit), Max.":"35 V; 35 V continuous; 75 V for max. 1 ms (mark to space ratio 1:20)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$75.00 – $224.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e5444c2a6d45e12e1a825e1259ff12c7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=135505&mlfb=6ES7134-4FB01-0AB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7134-4FB01-0AB0/alternatives.json"},"ai":{"faq":[{"question":"What voltage does 6ES7134-4FB01-0AB0 need to operate?","answer":"It runs on 24 V DC supplied from the ET 200S power module on the backplane bus — no separate field supply needed for the module itself. The load voltage L+ also comes from the power module, drawing up to 30 mA without load."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7134-4FB01-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7134-4FB01-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}