{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7134-4GB11-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7134-4GB11-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7134-4GB11-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7134-4GB11-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC DP, Electronics module for ET200S, 2AI Standard I-4DMU, 15 mm width, ±20 mA / 4-20 mA, 14-bit resolution.","salesMarkdown":"## What it is, where it fits The 6ES7134-4GB11-0AB0 is a SIMATIC DP electronics module for the ET200S distributed I/O system. It provides two analog current inputs, accepting both ±20 mA and 4-20 mA signals, with 14-bit resolution over the ±20 mA range and 13-bit for 4-20 mA. The module is 15 mm wide, consumes 0.6 W typical, and derives its 24 V DC supply from the backplane bus and load voltage L+. The integrating measurement principle with a per-channel conversion time of 65 ms means this module is suited for process signals that don't require high-speed updates — think temperature, pressure, or level transmitters rather than fast motion feedback. The 4-20 mA range enables wire-break diagnostics (configurable via software), but the destructive limit is 40 mA, so a shorted loop won't instantly kill the input. The digital filter can be set in four stages to match noise conditions; cycle time on all channels scales linearly with the number of active channels. No isochronous mode, so it cannot participate in equidistant PROFINET cycles. Width matters on a crowded ET200S rail. At 15 mm, this module leaves room for extra digital slices in the same station — a practical advantage when the panel designer is counting DIN-rail inches. ## Integration notes The module mounts on an ET200S terminal module (e.g., 6ES7193-4CC30-0AA0) and communicates via the backplane bus. Wiring is to the terminal module; the electronics module simply plugs in. The analog inputs are not isolated from each other, but the module is isolated from the backplane bus (tested at 500 V DC). For 4-20 mA loops, the shield is connected to the terminal module's shield terminal; max cable length 200 m shielded ensures signal integrity. Grounding should follow the ET200S system manual — one-point ground at the CPU side to avoid ground loops.","metaTitle":"Siemens 6ES7134-4GB11-0AB0 SIMATIC DP, 2AI, 15mm, ±20mA","metaDescription":"Active production. 2 analog inputs, ±20 mA / 4-20 mA, 14-bit resolution, 65 ms conversion per channel. 15 mm wide ET200S electronics module. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLC I/O & Expansion Modules"],"specifications":{"Depth":"52 mm","Width":"15 mm","title":"6ES7134-4GB11-0AB0","Height":"81 mm","Remark":"4 byte","Step: low":"Yes; 4x cycle time","Step: High":"Yes; 64x cycle time","Step: None":"Yes; 1x cycle time","Wire-break":"Yes; Measuring range 4 to 20 mA only","Group error":"Yes","description":"SIMATIC DP, Electronics module f. ET200S, 2AI Standard I-4DMU 15 mm width, +/-20mA; 13 bit+sign 4.. 20mA; 12-bit for 4-wire transmitter Cycle time 65 ms/channel with SF LED (group fault)","Step: Medium":"Yes; 32x cycle time","4 mA to 20 mA":"Yes; 50 Ohm","Shielded, Max.":"200 m","Parameterizable":"Yes; In four stages by means of digital filtering","Weight, approx.":"40 g","lifecycle_stage":"current","-20 mA to +20 mA":"Yes; 50 Ohm","Isochronous mode":"No","Power loss, typ.":"0.6 W","Rated value (DC)":"24 V; From power module","Group diagnostics":"Disable / enable","Overflow/underflow":"Disable / enable","Between The Channels":"No","Group error SF (red)":"Yes","Integration time (ms)":"16,7 / 20 ms","Isolation tested with":"500 V DC","Measurement principle":"integrating","Diagnostics wire break":"Disable / enable (only in measuring range 4 to 20 mA)","Number of analog inputs":"2","Conversion time (per channel)":"65 ms; 55 / 65 ms","Address space per module, max.":"4 byte","Cycle time (all channels) max.":"Number of active channels per module x basic conversion time","from backplane bus 3.3 V DC, max.":"10 mA","Between The Channels And Backplane Bus":"Yes","Current, relative to input range, (+/-)":"0.4 %","Between the channels and load voltage L+":"No","from load voltage L+ (without load), max.":"30 mA","Resolution with overrange (bit including sign), max.":"14 bit; ±20 mA: 14 bit, 4 to 20 mA: 13 bit","Interference voltage suppression for interference frequency f1 in Hz":"50 / 60 Hz","Permissible Input Current For Current Input (Destruction Limit), Max.":"40 mA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$265.43 – $392.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e5444c2a6d45e12e1a825e1259ff12c7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=470950&mlfb=6ES7134-4GB11-0AB0"},"ai":{"faq":[{"question":"What are the key specifications of this analog input module?","answer":"It has 2 analog inputs for ±20 mA or 4-20 mA, 14-bit resolution (±20 mA) or 13-bit (4-20 mA), conversion time 65 ms per channel, 15 mm width, 0.6 W typical power loss, and diagnostic features including wire-break detection (4-20 mA only) and group error indication."},{"question":"How do I source this module?","answer":"This is an active-production part. Submit an RFQ to our sourcing team for pricing and availability; we can quote against your BOM line."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7134-4GB11-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7134-4GB11-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}