{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7134-4GB60-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7134-4GB60-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7134-4GB60-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7134-4GB60-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC DP electronic module 6ES7134-4GB60-0AB0, 2 analog inputs high-speed for 4-wire transducers, 4 to 20 mA, 12-bit, 15 mm wide, for ET 200S.","salesMarkdown":"## 2 analog inputs for 4-wire transducers The Siemens 6ES7134-4GB60-0AB0 is a SIMATIC DP electronic module for the ET 200S distributed I/O system, providing 2 analog inputs for 4-wire transmitters with a 4 to 20 mA signal range. It delivers a 12-bit resolution with overrange and a per-channel conversion time of 0.1 ms, giving a module cycle time of 1 ms for all channels — fast enough for most process-value updates on a packaging or material-handling line. ## Diagnostics and signal conditioning Built-in wire-break detection and group diagnostics (red SF LED) are individually enable/disable per channel, so you can suppress nuisance alarms on unused inputs while keeping fault coverage on active loops. Overflow/underflow detection is also configurable per channel, and the module reports a group error when any enabled diagnostic trips. The input circuit is isolated between channels and the backplane bus, but there is no isolation between the channels themselves — keep that in mind if your two loops share a common reference that could differ in potential. ## Power budget and wiring reach The module draws its 24 V DC from the ET 200S power module, consuming 35 mA max from the load voltage L+ (unloaded) and 10 mA from the 3.3 V backplane bus. Shielded cable runs up to 200 m are permissible; the destruction limit for the current input is 35 mA, so a shorted loop will not immediately damage the input stage.","metaTitle":"Siemens 6ES7134-4GB60-0AB0 2AI High Speed, 4-20 mA, 15 mm","metaDescription":"Siemens 6ES7134-4GB60-0AB0 SIMATIC DP electronic module for ET 200S. 2 analog inputs, 4-20 mA, 12-bit, 1 ms cycle. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLC I/O & Expansion Modules"],"specifications":{"Depth":"52 mm","Width":"15 mm","Height":"81 mm","Remark":"4 byte","Wire-break":"Yes","Group error":"Yes","4 mA to 20 mA":"Yes","Shielded, Max.":"200 m","Weight, approx.":"40 g","lifecycle_stage":"current","Power loss, typ.":"0.8 W","Rated value (DC)":"24 V; From power module","Group diagnostics":"Disable / enable","Overflow/underflow":"Disable / enable","Between The Channels":"No","Group error SF (red)":"Yes","Diagnostics wire break":"Disable / enable","Measurement type/range":"deactivated / 4 to 20 mA","Number of analog inputs":"2","Conversion time (per channel)":"0.1 ms","Address space per module, max.":"4 byte","Cycle time (all channels) max.":"1 ms","from backplane bus 3.3 V DC, max.":"10 mA","Between The Channels And Backplane Bus":"Yes","Current, relative to input range, (+/-)":"0.7 %","Between the channels and load voltage L+":"No","from load voltage L+ (without load), max.":"35 mA","Resolution with overrange (bit including sign), max.":"12 bit","Permissible Input Current For Current Input (Destruction Limit), Max.":"35 mA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$400.05","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e5444c2a6d45e12e1a825e1259ff12c7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=485606&mlfb=6ES7134-4GB60-0AB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7134-4GB60-0AB0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 6ES7134-4GB60-0AB0?","answer":"Submit a request for quote to confirm availability and current pricing."},{"question":"Is 6ES7134-4GB60-0AB0 compatible with my ET 200S system?","answer":"Yes, this module is designed for the ET 200S distributed I/O system. It snaps onto the standard terminal module and communicates over the backplane bus. It requires a 24 V DC power module in the same station."},{"question":"Does 6ES7134-4GB60-0AB0 support 4-wire transducers?","answer":"Yes, the module is specifically designed for 4-wire transducers with a 4 to 20 mA output. It provides 2 analog inputs for this type of transmitter."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7134-4GB60-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7134-4GB60-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}