{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7134-4NB50-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7134-4NB50-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7134-4NB50-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7134-4NB50-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens ET 200S 4AI RTD module, 6ES7134-4NB50-0AB0, 4 analog inputs for Pt100, Ni100, Cu10 RTDs, 15 x 81 x 52 mm, active production.","salesMarkdown":"## What this RTD module reads and where it drops in The Siemens 6ES7134-4NB50-0AB0 is a 4-channel analog input module for the ET 200S distributed I/O system, purpose-built for resistance temperature detectors. It reads Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni200, Ni500, Ni1000, and Cu10 — essentially the full roster of common platinum, nickel, and copper RTD curves. That covers most temperature sensing in industrial process lines without needing a separate converter per probe type. Power comes from the ET 200S backplane at 24 VDC — no separate field supply needed. The module draws 0.6 W typical, which keeps the thermal budget in a densely packed terminal block cluster manageable. It uses a sigma-delta integrating measurement principle, with a selectable integration time of 16.7 ms or 20 ms. The 20 ms setting rejects 50 Hz line noise cleanly; 16.7 ms handles 60 Hz. That matters when you are running RTD leads past VFDs or welding supplies in the same cabinet. ## Filtering, diagnostics, and cable reach Digital filtering is configurable in four stages: none (1× cycle time), low (4×), medium (32×), or high (64×). The high setting smooths a noisy signal but adds latency — fine for a slow thermal process, not for a fast-reacting temperature loop on a plastic extruder barrel. Diagnostics cover wire-break, overflow/underflow, and group error — each can be enabled or disabled independently. The group error is mapped to the red SF LED on the module face, so a glance at the rack tells you if any channel is faulted. Isolation between channels is not provided; the module is tested at 500 V DC between the I/O and the backplane. Maximum shielded cable length is 200 m. That is generous for a distributed I/O slice — you can reach a tank farm at the far end of the plant without a repeater, as long as the RTD leads are twisted-pair and grounded at one end. No isochronous mode — this module is not for time-synchronized motion axes. It is a straight temperature input slice for process and discrete manufacturing. No stock-holding claim; each order is verified against the BOM quantity.","metaTitle":"Siemens 6ES7134-4NB50-0AB0 RTD Module, 4-Channel, Active","metaDescription":"Siemens 6ES7134-4NB50-0AB0 ET 200S 4AI RTD module. Supports Pt100, Ni100, Cu10. Active production, sourced per RFQ. 52 mm depth, 15 mm width.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLC I/O & Expansion Modules"],"specifications":{"Cu 10":"Yes","Depth":"52 mm","Width":"15 mm","Height":"81 mm","Ni 100":"Yes","Ni 120":"Yes","Ni 200":"Yes","Ni 500":"Yes","Pt 100":"Yes","Pt 200":"Yes","Pt 500":"Yes","Remark":"4 byte","Ni 1000":"Yes","Present":"Yes","Pt 1000":"Yes","Step: low":"Yes; 4x cycle time","Step: High":"Yes; 64x cycle time","Step: None":"Yes; 1x cycle time","Wire-break":"Yes","Group error":"Yes","Step: Medium":"Yes; 32x cycle time","0 To 150 Ohms":"Yes","0 To 300 Ohms":"Yes","0 To 600 Ohms":"Yes","0 To 3000 Ohms":"Yes","Shielded, Max.":"200 m","Parameterizable":"Yes; In four stages by means of digital filtering","Weight, approx.":"40 g","lifecycle_stage":"current","Isochronous mode":"No","Power loss, typ.":"0.6 W","Rated value (DC)":"24 V; From power module","Group diagnostics":"Disable / enable","Overflow/underflow":"Disable / enable","Between The Channels":"No","Group error SF (red)":"Yes","Integration time (ms)":"16,7 / 20 ms","Isolation tested with":"500 V DC","Measurement principle":"integrating (Sigma-Delta)","Diagnostics wire break":"Disable / enable","Measurement type/range":"Deactivated/ 150 Ohm / 300 Ohm / 600 Ohm /Pt100/Pt200/Pt500/Pt1000 each standard or climate range / Ni100/Ni120/Ni200/Ni500/Ni1000 each standard or climate range / Cu10 each standard or climate range / PTC","Number of analog inputs":"2","Input resistance (Cu 10)":"10 MΩ","Input resistance (Ni 100)":"10 MΩ","Input resistance (Ni 120)":"10 MΩ","Input resistance (Ni 200)":"10 MΩ","Input resistance (Ni 500)":"10 MΩ","Input resistance (Pt 100)":"10 MΩ","Input resistance (Pt 200)":"10 MΩ","Input resistance (Pt 500)":"10 MΩ","For Resistance Thermometer":"Ptxxx, Nixxx","Input resistance (Ni 1000)":"10 MΩ","Input resistance (Pt 1000)":"10 MΩ","Reverse polarity protection":"Yes","Conversion time (per channel)":"Basic conversion time incl. integration time: 50 / 60 ms; additional conversion time for diagnostics of wire break test: 5 / 5 ms; additional conversion time for line compensation with 3-wire connection: 50 / 60 ms","Address space per module, max.":"4 byte","Cycle time (all channels) max.":"Number of active channels per module x basic conversion time","Input resistance (0 to 150 ohms)":"10 MΩ","Input resistance (0 to 300 ohms)":"10 MΩ","Input resistance (0 to 600 ohms)":"10 MΩ","Input resistance (0 to 3000 ohms)":"10 MΩ","Integration time, parameterizable":"Yes","Internal Temperature Compensation":"Yes","from backplane bus 3.3 V DC, max.":"10 mA","between MANA and M internally (UISO)":"75 V DC/60 V AC","Between The Channels And Backplane Bus":"Yes","Between the channels and load voltage L+":"Yes","from load voltage L+ (without load), max.":"30 mA","For Resistance Measurement With Two-Wire Connection":"Yes","For Resistance Measurement With Four-Wire Connection":"Yes","Resolution with overrange (bit including sign), max.":"16 bit; for Pt100, Ni100, Ni120, Pt200, Ni200, Pt500, Ni500, Pt1000, Ni1000, Cu10: 15 bit + sign; for 150, 300, 600, 3 000 ohms: 15 bit; for PTC: 1 bit","For Resistance Measurement With Three-Wire Connection":"Yes; internal compensation of the line resistances","Technical unit for temperature measurement adjustable":"Yes","Resistance thermometer, relative to input range, (+/-)":"Resistance-type transmitter: ±0.05 %; Pt100, Pt200, Pt500, Pt1000 standard: ±0.6 K; Pt100, Pt200, Pt500, Pt1000 climate: ±0.13 K; Ni100, Ni120, Ni200, Ni500, Ni1000 standard and climate: ±0.2 K; Cu10 ±1 K","Constant measurement current for resistance-type transmitter, typ.":"1.25 mA","Interference voltage suppression for interference frequency f1 in Hz":"50 / 60 Hz","Permissible Input Voltage For Voltage Input (Destruction Limit), Max.":"9 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,002.92","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e5444c2a6d45e12e1a825e1259ff12c7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=226255&mlfb=6ES7134-4NB50-0AB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7134-4NB50-0AB0/alternatives.json"},"ai":{"faq":[{"question":"What RTD types does the 6ES7134-4NB50-0AB0 support?","answer":"It supports Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni200, Ni500, Ni1000, and Cu10. That covers the common platinum, nickel, and copper RTD curves used in industrial temperature measurement."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7134-4NB50-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7134-4NB50-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}