{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7134-6FF00-0AA1","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7134-6FF00-0AA1","canonicalUrl":"https://aoctrl.com/siemens/6ES7134-6FF00-0AA1","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7134-6FF00-0AA1","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 6ES7134-6FF00-0AA1, ET 200SP analog input module, 8 channels single-ended, 0-10V 15 bit, ±10V 16 bit incl. sign, 24 V DC, 58 mm depth, 15 mm width, current production.","salesMarkdown":"The 6ES7134-6FF00-0AA1: It draws 25 mA from the backplane and dissipates 0.7 W typically—useful for power budgeting on a dense ET 200SP station. The module fits a 15 mm wide slot and works with BaseUnits type A0 and A1 (1-wire and 2-wire connection supported). Occupies a 15 mm slice on the ET 200SP bus adapter; depth is 58 mm, height 73 mm. Shielded analog cable runs up to 200 m are allowed for the voltage inputs. Mechanical coding element prevents incorrect insertion; automatic encoding identifies the module to the backplane.","metaTitle":"Siemens 6ES7134-6FF00-0AA1 ET 200SP AI, 8xU, 15/16bit","metaDescription":"Siemens 6ES7134-6FF00-0AA1 analog input module for ET 200SP, 8 channels single-ended, ±10V/0-10V, 15/16 bit, current production, 58mm depth. Source via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Analog Input Modules"],"specifications":{"MSI":"No","Depth":"58 mm","Width":"15 mm","Height":"73 mm","I&M data":"Yes; I&M0 to I&M3","0 to +10 V":"Yes; 15 bit","Wire-break":"No","Group error":"Yes","Oversampling":"No","Short-circuit":"No","-10 V to +10 V":"Yes; 16 bit incl. sign","Shielded, Max.":"200 m","Parameterizable":"Yes","Weight, approx.":"31 g","lifecycle_stage":"current","Diagnostic alarm":"Yes","Isochronous mode":"No","Power loss, typ.":"0.7 W","Rated value (DC)":"24 V","usable BaseUnits":"BU type A0, A1","1-Wire Connection":"BU type A0, A1","2-Wire Connection":"BU type A0, A1","Limit value alarm":"No","Automatic encoding":"Yes","FW update possible":"Yes","Overflow/underflow":"Yes","Between The Channels":"No","Diagnostics function":"Yes","HW functional status":"from FS04","Isolation tested with":"707 V DC (type test)","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; green/red DIAG LED","For Channel Diagnostics":"No","For Voltage Measurement":"Yes","For voltage measurement":"8","Number of analog inputs":"8; Single-ended","Measuring range scalable":"No","Current consumption, max.":"25 mA","Mechanical coding element":"Yes","Number of smoothing levels":"4; None; 4/8/16 times","Calibration possible in RUN":"No","Reverse polarity protection":"Yes","Vertical Installation, Max.":"50 °C","Vertical Installation, Min.":"-30 °C; < 0 °C as of FS04","Input resistance (0 to 10 V)":"100 kΩ","Conversion time (per channel)":"180 / 60 / 50 / 0.625 (67.5 / 22.5 / 18.75) ms","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"-30 °C; < 0 °C as of FS04","Monitoring the supply voltage":"Yes","Address space per module, max.":"16 byte","Cycle time (all channels), min.":"1 ms; per channel","Input resistance (-10 V to +10 V)":"100 kΩ","Integration time, parameterizable":"Yes","Type of mechanical coding element":"type B","Crosstalk between the inputs, min.":"-50 dB","Reparameterization possible in RUN":"Yes","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Between The Channels And Backplane Bus":"Yes","PROFIBUS from GSD version/GSD revision":"One GSD file each, Revision 3 and 5 and higher","PROFINET from GSD version/GSD revision":"GSDML V2.3","Voltage, relative to input range, (+/-)":"0.3 %","Monitoring of the supply voltage (PWR-LED)":"Yes; green PWR LED","Installation altitude above sea level, max.":"5 000 m; Restrictions for installation altitudes > 2 000 m, see manual","STEP 7 configurable/integrated from version":"V5.5 SP3 / -","For Current Measurement As 4-Wire Transducer":"No","Linearity error (relative to input range), (+/-)":"0.01 %","Temperature error (relative to input range), (+/-)":"0.005 %/K","Resolution with overrange (bit including sign), max.":"16 bit","STEP 7 TIA Portal configurable/integrated from version":"V13 SP1","Color code for module-specific color identification plate":"CC02","Between The Channels And The Power Supply Of The Electronics":"No","Interference voltage suppression for interference frequency f1 in Hz":"16.67 / 50 / 60 / 4 800 (16.67 / 50 / 60)","Permissible Input Voltage For Voltage Input (Destruction Limit), Max.":"30 V","Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)":"0.05 %","Series mode interference (peak value of interference < rated value of input range), min.":"70 dB; With conversion time 67.5 / 22.5 / 18.75 ms: 40 dB"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$157.48","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/094b59a3ced6e56586fc0cef50d2ca54.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=571032&mlfb=6ES7134-6FF00-0AA1","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7134-6FF00-0AA1/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7134-6FF00-0AA1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7134-6FF00-0AA1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}