{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7134-6GF00-0AA1","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7134-6GF00-0AA1","canonicalUrl":"https://aoctrl.com/siemens/6ES7134-6GF00-0AA1","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7134-6GF00-0AA1","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC ET 200SP analog input module, 6ES7134-6GF00-0AA1, 8 single-ended inputs, 24 V DC, current production.","salesMarkdown":"## Eight channels, one module width The Siemens 6ES7134-6GF00-0AA1 is an 8-channel analog input module for the ET 200SP distributed I/O system. It accepts 0 to 20 mA, 4 to 20 mA, and -20 to +20 mA signals, all single-ended, so you get eight process-variable inputs in a 15 mm-wide slice on the DIN rail. Each channel is field-wired through a BaseUnit — type A0 or A1 for 2-wire transmitters, and type A0 or A1 plus a potential distributor module for 4-wire transmitters. The module encodes its identity automatically when you seat it on the BaseUnit, so the configuration software picks up the slot without manual addressing. ## Diagnostics that save a trip out to the panel Wire-break detection is active on 4 to 20 mA channels, and short-circuit detection monitors the sensor supply to M, module by module. When either fault hits, the module fires a diagnostic alarm and lights the red/green DIAG LED — you know which slice is down without opening the cabinet door. Power loss is 0.7 W typical without encoder supply, and the total encoder current available across all channels is 0.7 A. That matters when you're feeding loop-powered transmitters — stay under the ceiling or add a separate supply. I&M data (I&M0 to I&M3) is supported, so the module carries its own identity and maintenance history in the tag database. The firmware can be updated in the field, and the hardware functional status starts at FS04. ## Current production, sourced per RFQ The 15 mm width and 58 mm depth fit standard ET 200SP mounting rails; order the matching BaseUnits separately.","metaTitle":"Siemens 6ES7134-6GF00-0AA1, 8-Channel Analog Input Module","metaDescription":"Siemens 6ES7134-6GF00-0AA1 ET 200SP analog input module, 8 single-ended inputs, 24 V DC, current production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Analog Input Modules"],"specifications":{"MSI":"No","24 V":"Yes","Depth":"58 mm","Width":"15 mm","Height":"73 mm","I&M data":"Yes; I&M0 to I&M3","0 to 20 mA":"Yes","Wire-break":"Yes; at 4 to 20 mA","Group error":"Yes","Oversampling":"No","4 mA to 20 mA":"Yes","Short-circuit":"Yes; Sensor supply to M; module by module","Shielded, Max.":"200 m","Parameterizable":"Yes","Weight, approx.":"31 g","lifecycle_stage":"current","-20 mA to +20 mA":"Yes","Diagnostic alarm":"Yes","Isochronous mode":"No","Power loss, typ.":"0.7 W; Without encoder supply voltage","Rated value (DC)":"24 V","usable BaseUnits":"BU type A0, A1","1-Wire Connection":"BU type A0, A1","2-Wire Connection":"BU type A0, A1","4-Wire Connection":"BU type A0, A1 + potential distributor module","Limit value alarm":"No","Automatic encoding":"Yes","FW update possible":"Yes","Overflow/underflow":"Yes","Between The Channels":"No","Diagnostics function":"Yes","HW functional status":"from FS04","Output current, max.":"0.7 A; total current of all encoders/channels","Isolation tested with":"707 V DC (type test)","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; green/red DIAG LED","For Channel Diagnostics":"No","For Voltage Measurement":"No","For current measurement":"8","Number of analog inputs":"8; Single-ended","Measuring range scalable":"No","Short-circuit protection":"Yes","Current consumption, max.":"25 mA; without sensor supply","Mechanical coding element":"Yes","Number of smoothing levels":"4; None; 4/8/16 times","Calibration possible in RUN":"No","Reverse polarity protection":"Yes","Vertical Installation, Max.":"50 °C","Vertical Installation, Min.":"-30 °C; < 0 °C as of FS04","Conversion time (per channel)":"180 / 60 / 50 / 0.625 (67.5 / 22.5 / 18.75) ms","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"-30 °C; < 0 °C as of FS04","Input resistance (0 to 20 mA)":"100 Ω; 15 bit","Monitoring the supply voltage":"Yes","Address space per module, max.":"16 byte","Cycle time (all channels), min.":"1 ms; per channel","Input resistance (4 mA to 20 mA)":"100 Ω; 15 bit","Integration time, parameterizable":"Yes","Type of mechanical coding element":"Type A","Burden of 2-wire transmitter, max.":"650 Ω","Crosstalk between the inputs, min.":"50 dB","Reparameterization possible in RUN":"Yes","Input resistance (-20 mA to +20 mA)":"100 Ω; 16 bit incl. sign","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Between The Channels And Backplane Bus":"Yes","PROFIBUS from GSD version/GSD revision":"One GSD file each, Revision 3 and 5 and higher","PROFINET from GSD version/GSD revision":"GSDML V2.3","Current, relative to input range, (+/-)":"0.3 %","Monitoring of the supply voltage (PWR-LED)":"Yes; green LED","Installation altitude above sea level, max.":"5 000 m; Restrictions for installation altitudes > 2 000 m, see manual","STEP 7 configurable/integrated from version":"V5.5 SP3 / -","For Current Measurement As 2-Wire Transducer":"Yes","For Current Measurement As 4-Wire Transducer":"Yes","Linearity error (relative to input range), (+/-)":"0.01 %","Temperature error (relative to input range), (+/-)":"0.005 %/K","Resolution with overrange (bit including sign), max.":"16 bit","STEP 7 TIA Portal configurable/integrated from version":"V13 SP1","Color code for module-specific color identification plate":"CC01","Between The Channels And The Power Supply Of The Electronics":"No","Interference voltage suppression for interference frequency f1 in Hz":"16.67 / 50 / 60 / 4 800 (16.67 / 50 / 60)","Permissible Input Current For Current Input (Destruction Limit), Max.":"50 mA","Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)":"0.05 %","Series mode interference (peak value of interference < rated value of input range), min.":"70 dB; With conversion time 67.5 / 22.5 / 18.75 ms: 40 dB"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$157.48","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b5108594756a4bfddef9b2305958f015.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=571033&mlfb=6ES7134-6GF00-0AA1","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7134-6GF00-0AA1/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7134-6GF00-0AA1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7134-6GF00-0AA1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}