{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7134-6HB00-0CA1","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7134-6HB00-0CA1","canonicalUrl":"https://aoctrl.com/siemens/6ES7134-6HB00-0CA1","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7134-6HB00-0CA1","rawCanonicalId":null},"summary":{"shortDescription":"Siemens ET 200SP, Analog Input Module, 6ES7134-6HB00-0CA1, 24 V, 15 mm, MSI, 15/16-bit resolution, diagnostics.","salesMarkdown":"## What the 6ES7134-6HB00-0CA1 brings to your I/O rack The 6ES7134-6HB00-0CA1 is a Siemens ET 200SP analog input module with 24 V backplane supply and MSI (Module Startup Information) that speeds commissioning by auto-identifying the module and its parameters in TIA Portal. At 15 mm wide it occupies just one slice on the DIN rail, but packs four analog inputs configurable between voltage (0–10 V, ±10 V, 1–5 V, ±5 V) or current (0–20 mA, 4–20 mA, ±20 mA), each with 15-bit (unipolar) or 16-bit (bipolar plus sign) resolution. Sigma-delta measurement with integration times from 0.625 ms to 67.5 ms lets you trade cycle speed against noise rejection. The module supports isochronous mode for deterministic data exchange with jitter max 5 µs — essential if the input feeds a motion or high-speed logic loop. ## Diagnostics and commissioning details Wire-break detection is active only on the 4–20 mA range — if you use 0–20 mA or voltage, plan external continuity checks. Short-circuit monitoring works channel-by-channel for 1–5 V or the encoder supply output. Diagnostic and limit-value alarms can trigger group error on the backplane bus, so a single fault flags the whole station while you pinpoint the channel via TIA Portal. The module supports I&M data (I&M0 through I&M3) and firmware update over the backplane. It is parameterizable per channel. Maximum shielded cable length is 1 000 m (200 m for voltage inputs). Output current for a 4-wire transmitter supply is 100 mA continuous, with a 150 mA peak for under 10 seconds. Rated power loss is 0.95 W typ (without sensor load). The isolation test is at 707 V DC (type test), which is typical for ET 200SP but worth noting if you are adjacent to high-voltage sections.","metaTitle":"Siemens 6ES7134-6HB00-0CA1 ET 200SP Analog Input, 15 mm","metaDescription":"Siemens 6ES7134-6HB00-0CA1 ET 200SP analog input module, 24 V, 15 mm, 15/16-bit, with MSI, diagnostics, isochronous mode. Sourced to order for new builds or spares.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Analog Input Modules"],"specifications":{"MSI":"Yes","24 V":"Yes","Depth":"58 mm","Width":"15 mm","title":"6ES7134-6HB00-0CA1","Height":"73 mm","I&M data":"Yes; I&M0 to I&M3","0 to +10 V":"Yes; 15 bit","0 to 20 mA":"Yes; 15 bit","1 V to 5 V":"Yes; 15 bit","Wire-break":"Yes; Measuring range 4 to 20 mA only","Group error":"Yes","description":"SIMATIC ET 200SP, Analog input module, AI 2x U/I 2-.4-wire High Feat., suitable for BU type A0, A1, Color code CC05, channel diagnostics, 16 bit, +/-0.1%","-5 V to +5 V":"Yes; 16 bit incl. sign","Jitter, max.":"5 µs","Oversampling":"No","4 mA to 20 mA":"Yes; 15 bit","Short-circuit":"Yes; channel-by-channel, at 1 to 5 V or for short-circuit in encoder supply","-10 V to +10 V":"Yes; 16 bit incl. sign","Shielded, Max.":"1 000 m; 200 m for voltage measurement","Parameterizable":"Yes","Weight, approx.":"32 g","lifecycle_stage":"current","-20 mA to +20 mA":"Yes; 16 bit incl. sign","Diagnostic alarm":"Yes","Isochronous mode":"Yes","Power loss, typ.":"0.95 W; without sensor supply","Rated value (DC)":"24 V","usable BaseUnits":"BU type A0, A1","2-Wire Connection":"BU type A0, A1","4-Wire Connection":"BU type A0, A1","Limit value alarm":"Yes; two upper and two lower limit values in each case","Automatic encoding":"Yes","FW update possible":"Yes","Overflow/underflow":"Yes","Between The Channels":"Yes","Diagnostics function":"Yes","HW functional status":"From FS06","Output current, max.":"100 mA; max. 150 mA for a duration of < 10 s (four-wire)","Integration time (ms)":"67.5 / 22.5 / 18.75 / 10 / 5 / 2.5 / 1.25 / 0.625 ms","Isolation tested with":"707 V DC (type test)","Measurement principle":"Sigma Delta","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; green/red DIAG LED","For Channel Diagnostics":"Yes; red LED","For Voltage Measurement":"Yes","For current measurement":"2","For voltage measurement":"2","Number of analog inputs":"2; Differential inputs","Measuring range scalable":"No","Short-circuit protection":"Yes; channel by channel","Common mode voltage, max.":"35 V","Mechanical coding element":"Yes","Bus cycle time (TDP), min.":"1 ms","Number of smoothing levels":"6; none; 2-/4-/8-/16-/32-fold","Calibration possible in RUN":"Yes","Reverse polarity protection":"Yes","Vertical Installation, Max.":"50 °C","Vertical Installation, Min.":"-30 °C; < 0 °C as of FS06","Input resistance (0 to 10 V)":"75 kΩ","Conversion time (per channel)":"68.2 / 23 / 19.2 / 10.45 / 5.40 / 2.85 / 1.6 / 0.9 ms","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"-30 °C; < 0 °C as of FS06","Input resistance (0 to 20 mA)":"130 Ω","Input resistance (1 V to 5 V)":"75 kΩ","Monitoring the supply voltage":"Yes","Address space per module, max.":"4 byte; + 4 byte for scaling of measured values, + 1 byte for QI information","Analog input with oversampling":"No","Common mode interference, min.":"90 dB","Input resistance (-5 V to +5 V)":"75 kΩ","Input resistance (4 mA to 20 mA)":"130 Ω","Current consumption (rated value)":"39 mA; without sensor supply","Input resistance (-10 V to +10 V)":"75 kΩ","Integration time, parameterizable":"Yes","Type of mechanical coding element":"Type A","Burden of 2-wire transmitter, max.":"650 Ω","Crosstalk between the inputs, min.":"-50 dB","Reparameterization possible in RUN":"Yes","Standardization of measured values":"Yes","Input resistance (-20 mA to +20 mA)":"130 Ω","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Between The Channels And Backplane Bus":"Yes","PROFIBUS from GSD version/GSD revision":"One GSD file each, Revision 3 and 5 and higher","PROFINET from GSD version/GSD revision":"GSDML V2.3","Current, relative to input range, (+/-)":"0.05 %; 0.1 % at SFU 4.8 kHz","Voltage, relative to input range, (+/-)":"0.05 %; 0.1 % at SFU 4.8 kHz","Filtering and processing time (TCI), min.":"800 µs","Monitoring of the supply voltage (PWR-LED)":"Yes; green PWR LED","PCS 7 configurable/integrated from version":"V8.1 SP1","Installation altitude above sea level, max.":"5 000 m; Restrictions for installation altitudes > 2 000 m, see manual","STEP 7 configurable/integrated from version":"V5.5 / -","For Current Measurement As 2-Wire Transducer":"Yes","For Current Measurement As 4-Wire Transducer":"Yes","Linearity error (relative to input range), (+/-)":"0.01 %","Temperature error (relative to input range), (+/-)":"0.003 %/K","Resolution with overrange (bit including sign), max.":"16 bit","Basic conversion time, including integration time (ms)":"68.03 / 22.83 / 19.03 / 10.28 / 5.23 / 2.68 / 1.43 / 0.730 ms","STEP 7 TIA Portal configurable/integrated from version":"V13","Color code for module-specific color identification plate":"CC03","Basic execution time of the module (all channels released)":"1 ms","Between The Channels And The Power Supply Of The Electronics":"Yes","Interference voltage suppression for interference frequency f1 in Hz":"16.6 / 50 / 60 / 300 / 600 / 1 200 / 2 400 / 4 800","Permissible Input Current For Current Input (Destruction Limit), Max.":"50 mA","Permissible Input Voltage For Voltage Input (Destruction Limit), Max.":"30 V","Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)":"0.01 %"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$156.21","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/01af3b32975e1eebc13716fcf9f27de0.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=42221&mlfb=6ES7134-6HB00-0CA1"},"ai":{"faq":[{"question":"What does MSI (Yes) mean for this module?","answer":"MSI stands for Module Startup Information. It lets the module auto-identify and configure itself in TIA Portal, reducing manual parameter assignment during commissioning."},{"question":"Does this module support isochronous mode?","answer":"Yes, it supports isochronous mode with a maximum jitter of 5 µs, enabling deterministic data exchange for synchronized applications."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7134-6HB00-0CA1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7134-6HB00-0CA1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}