{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7134-6HB00-0DA1","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7134-6HB00-0DA1","canonicalUrl":"https://aoctrl.com/siemens/6ES7134-6HB00-0DA1","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7134-6HB00-0DA1","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC ET 200SP, analog input module, 2 AI, 2-wire, 4-wire, 15/16 bit, ±10 V, 4-20 mA, oversampling, 15 mm width.","salesMarkdown":"The Siemens 6ES7134-6HB00-0DA1 is a 2‑channel analog input module for the SIMATIC ET 200SP distributed I/O system. It handles voltage (±10 V, 1–5 V, 0–10 V) and current (0–20 mA, 4–20 mA, ±20 mA) ranges with resolutions from 13 to 16 bits including sign. Oversampling delivers a minimum resolution of 50 µs per channel, letting it capture fast transients on two channels simultaneously. This module is listed as current production. Lead time is subject to Siemens allocation; we quote it to order against a BOM line with blanket-pricing options for volume builds. ## Mechanical fit and wiring It mounts in BU type A0 or A1 base units (ordered separately). Base unit choice decides the wiring connection — 2‑wire or 4‑wire — and provides the 24 V supply needed for current measurement. At 15 mm wide, it takes up less DIN rail space than a standard 20 mm module. ## Diagnostics and signal conditioning Channel‑by‑channel alarms detect wire‑break (4–20 mA only), short‑circuit (voltage or current encoder supply), overflow, and underflow. A group error signal triggers on any fault. Isochronous mode supports precise time‑stamped data, and I&M data (I&M0 to I&M3) provides module identification and maintenance records.","metaTitle":"Siemens 6ES7134-6HB00-0DA1 2Ch Analog Input Module","metaDescription":"Active ET 200SP analog input module with oversampling and diagnostics. 2 channels, 0-10V, 4-20mA, 15/16-bit. 15 mm width. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Analog Input Modules"],"specifications":{"MSI":"No","24 V":"Yes; For current measurement","Depth":"58 mm","Width":"15 mm","title":"6ES7134-6HB00-0DA1","Height":"73 mm","I&M data":"Yes; I&M0 to I&M3","0 to +10 V":"Yes; 15 bit","0 to 20 mA":"Yes; 15 bit","1 V to 5 V":"Yes; 13 bit","Wire-break":"Yes; channel-by-channel, at 4 to 20 mA only","Group error":"Yes","description":"SIMATIC ET 200SP, Analog input module, AI 2x U/I 2-.4-wire High Speed, suitable for BU type A0, A1, Color code CC00, channel diagnostics, 16 bit, +/-0.3%","-5 V to +5 V":"Yes; 15 bit incl. sign","Oversampling":"Yes; 2 channels per module","4 mA to 20 mA":"Yes; 14 bit","Short-circuit":"Yes; channel-by-channel, at 1 to 5 V or for current measuring ranges short-circuit in encoder supply","-10 V to +10 V":"Yes; 16 bit incl. sign","Shielded, Max.":"1 000 m; 200 m for voltage measurement","Parameterizable":"Yes","Weight, approx.":"32 g","lifecycle_stage":"current","-20 mA to +20 mA":"Yes; 16 bit incl. sign","Diagnostic alarm":"Yes","Isochronous mode":"Yes","Power loss, typ.":"0.95 W; without sensor supply","Rated value (DC)":"24 V","Resolution, min.":"50 µs","usable BaseUnits":"BU type A0, A1","2-Wire Connection":"BU type A0, A1","4-Wire Connection":"BU type A0, A1","Limit value alarm":"Yes; two upper and two lower limit values in each case","Automatic encoding":"Yes","FW update possible":"Yes","Overflow/underflow":"Yes","Between The Channels":"Yes","HW functional status":"From FS07","Output current, max.":"20 mA; max. 50 mA per channel for a duration < 10 s","Isolation tested with":"707 V DC (type test)","Measurement principle":"Actual value encryption (successive approximation)","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; green/red DIAG LED","Values per cycle, max.":"16","For Channel Diagnostics":"Yes; red LED","For Voltage Measurement":"Yes","For current measurement":"2","For voltage measurement":"2","Number of analog inputs":"2; Differential inputs","Measuring range scalable":"No","Scalable measured values":"No","Short-circuit protection":"Yes","Common mode voltage, max.":"35 V","Mechanical coding element":"Yes","Bus cycle time (TDP), min.":"125 µs; Starting from firmware Version V2.0.1","Number of smoothing levels":"7; none; 2-/4-/8-/16-/32-/64-fold","Calibration possible in RUN":"No","Reverse polarity protection":"Yes","Vertical Installation, Max.":"50 °C","Vertical Installation, Min.":"-30 °C","Input resistance (0 to 10 V)":"75 kΩ","Adjustment of measuring range":"No","Conversion time (per channel)":"10 µs","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"-30 °C","Input resistance (0 to 20 mA)":"130 Ω","Input resistance (1 V to 5 V)":"75 kΩ","Address space per module, max.":"4 byte; + 1 byte for QI information (32 bytes in the oversampling operating mode)","Analog input with oversampling":"Yes","Common mode interference, min.":"90 dB","Cycle time (all channels), min.":"125 µs","Input resistance (-5 V to +5 V)":"75 kΩ","Input resistance (4 mA to 20 mA)":"130 Ω","Current consumption (rated value)":"39 mA; without sensor supply","Input resistance (-10 V to +10 V)":"75 kΩ","Type of mechanical coding element":"Type A","Burden of 2-wire transmitter, max.":"650 Ω","Crosstalk between the inputs, min.":"-50 dB","Reparameterization possible in RUN":"Yes","Input resistance (-20 mA to +20 mA)":"130 Ω","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Between The Channels And Backplane Bus":"Yes","PROFIBUS from GSD version/GSD revision":"One GSD file each, Revision 3 and 5 and higher","PROFINET from GSD version/GSD revision":"GSDML V2.3","Current, relative to input range, (+/-)":"0.2 %","Voltage, relative to input range, (+/-)":"0.2 %","Filtering and processing time (TCI), min.":"80 µs","Monitoring of the supply voltage (PWR-LED)":"Yes; green PWR LED","Installation altitude above sea level, max.":"5 000 m; Restrictions for installation altitudes > 2 000 m, see manual","STEP 7 configurable/integrated from version":"V5.5 SP3 / -","For Current Measurement As 2-Wire Transducer":"Yes","For Current Measurement As 4-Wire Transducer":"Yes","Linearity error (relative to input range), (+/-)":"0.03 %","Temperature error (relative to input range), (+/-)":"0.01 %/K","Resolution with overrange (bit including sign), max.":"16 bit","STEP 7 TIA Portal configurable/integrated from version":"V13 SP1","Color code for module-specific color identification plate":"CC00","Between The Channels And The Power Supply Of The Electronics":"Yes","Interference voltage suppression for interference frequency f1 in Hz":"No","Permissible Input Current For Current Input (Destruction Limit), Max.":"50 mA","Permissible Input Voltage For Voltage Input (Destruction Limit), Max.":"30 V","Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)":"0.1 %"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$164.55","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a57446db85a026ad23275c2ff8631da3.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=129051&mlfb=6ES7134-6HB00-0DA1"},"ai":{"faq":[{"question":"What does the MSI entry mean?","answer":"MSI is listed as No. This module does not support the multiple sensor interface; it is a standard analog input module."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7134-6HB00-0DA1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7134-6HB00-0DA1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}