{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7134-6JD00-0DA1","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7134-6JD00-0DA1","canonicalUrl":"https://aoctrl.com/siemens/6ES7134-6JD00-0DA1","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7134-6JD00-0DA1","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC ET 200SP, 6ES7134-6JD00-0DA1, Analog Input Module, 4 AI, 4- or 2-wire, thermocouple/mV, 16-bit, MSI Yes.","salesMarkdown":"## Wiring and integration The 6ES7134-6JD00-0DA1: Parameterizable wire-break detection per channel and group error alarm are built in. Diagnostic alarm and limit value alarm (two upper, two lower) are configurable. I&M data from I&M0 to I&M3 is supported for asset management.","metaTitle":"Siemens 6ES7134-6JD00-0DA1 Analog Input Module, 16-bit","metaDescription":"Siemens 6ES7134-6JD00-0DA1 ET 200SP AI module, 4-channel thermocouple/mV input, 16-bit, MSI Yes. Active lifecycle, order to RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Analog Input Modules"],"specifications":{"MSI":"Yes","Depth":"58 mm","Width":"15 mm","Height":"73 mm","Type B":"Yes; 16 bit incl. sign","Type C":"Yes; 16 bit incl. sign","Type E":"Yes; 16 bit incl. sign","Type J":"Yes; 16 bit incl. sign","Type K":"Yes; 16 bit incl. sign","Type L":"Yes; 16 bit incl. sign","Type N":"Yes; 16 bit incl. sign","Type R":"Yes; 16 bit incl. sign","Type S":"Yes; 16 bit incl. sign","Type T":"Yes; 16 bit incl. sign","Type U":"Yes; 16 bit incl. sign","I&M data":"Yes; I&M0 to I&M3","Step: low":"Yes","Step: High":"Yes","Step: None":"Yes","Wire-break":"Yes; channel by channel","Group error":"Yes","-1 V to +1 V":"Yes; 16 bit incl. sign","Oversampling":"No","Step: Medium":"Yes","Shielded, Max.":"200 m; 100 m for thermocouples","Parameterizable":"Yes","Weight, approx.":"33 g","lifecycle_stage":"current","-50 mV to +50 mV":"Yes; 16 bit incl. sign","-80 mV to +80 mV":"Yes; 16 bit incl. sign","Diagnostic alarm":"Yes","Isochronous mode":"No","Power loss, typ.":"0.9 W","Rated value (DC)":"24 V","usable BaseUnits":"BU type A0, A1","2-Wire Connection":"BU type A0, A1","Limit value alarm":"Yes; two upper and two lower limit values in each case","-250 mV to +250 mV":"Yes; 16 bit incl. sign","Automatic encoding":"Yes","FW update possible":"Yes","Overflow/underflow":"Yes; channel by channel","Between The Channels":"No","Diagnostics function":"Yes","HW functional status":"From FS02","Isolation tested with":"707 V DC (type test)","Measurement principle":"integrating (Sigma-Delta)","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; green/red LED","For Channel Diagnostics":"Yes; red LED","For Voltage Measurement":"Yes","Number of analog inputs":"4","Type TXK/TXK(L) to GOST":"Yes; 16 bit incl. sign","Measuring range scalable":"Yes","between the inputs (UCM)":"60 V DC","Common mode voltage, max.":"60 V; DC","Current consumption, max.":"50 mA","Input resistance (Type B)":"1 MΩ","Input resistance (Type C)":"1 MΩ","Input resistance (Type E)":"1 MΩ","Input resistance (Type K)":"1 MΩ","Input resistance (Type L)":"1 MΩ","Input resistance (Type N)":"1 MΩ","Input resistance (Type R)":"1 MΩ","Input resistance (Type S)":"1 MΩ","Input resistance (Type T)":"1 MΩ","Input resistance (Type U)":"1 MΩ","Input resistance (type J)":"1 MΩ","Internal Comparison Point":"Yes; with BaseUnit type A1","Mechanical coding element":"Yes","Number of smoothing levels":"4; None; 4/8/16 times","Calibration possible in RUN":"Yes","Fixed Reference Temperature":"Yes","Reverse polarity protection":"Yes","Vertical Installation, Max.":"50 °C","Vertical Installation, Min.":"-30 °C; < 0 °C as of FS02","Conversion time (per channel)":"180/60/50/1.25 ms","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"-30 °C; < 0 °C as of FS02","Monitoring the supply voltage":"Yes","Address space per module, max.":"16 byte; + 1 byte for QI information","Common mode interference, min.":"90 dB","Reference channel of the group":"Yes","Cycle time (all channels), min.":"5 ms; Sum of the basic conversion times and additional processing times (depending on the parameterization of the active channels)","Input resistance (-1 V to +1 V)":"1 MΩ","Reference channel of the module":"No","Current consumption (rated value)":"37 mA","Integration time, parameterizable":"Yes","Type of mechanical coding element":"Type A","Crosstalk between the inputs, min.":"-70 dB","Number of reference channel groups":"4; Group 0 to 3","Reparameterization possible in RUN":"Yes","Input resistance (-50 mV to +50 mV)":"1 MΩ","Input resistance (-80 mV to +80 mV)":"1 MΩ","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Input resistance (-250 mV to +250 mV)":"1 MΩ","Between The Channels And Backplane Bus":"Yes","PROFIBUS from GSD version/GSD revision":"One GSD file each, Revision 3 and 5 and higher","PROFINET from GSD version/GSD revision":"GSDML V2.3","Voltage, relative to input range, (+/-)":"0.05 %; 0.2 % when SFU OFF","Input resistance (Type TXK/TXK(L) to GOST)":"1 MΩ","Monitoring of the supply voltage (PWR-LED)":"Yes; green PWR LED","Installation altitude above sea level, max.":"5 000 m; Restrictions for installation altitudes > 2 000 m, see manual","STEP 7 configurable/integrated from version":"V5.5 SP3 or higher","Suitable for applications according to CQI-9":"Yes; Based on AMS 2750 E","Additional Processing Time For Wire-Break Check":"1 ms","Suitable for applications according to AMS 2750":"Yes; Declaration of Conformity, see online support entry 109757262","Linearity error (relative to input range), (+/-)":"0.01 %","Temperature error (relative to input range), (+/-)":"0.005 %/K","Resolution with overrange (bit including sign), max.":"16 bit","Technical unit for temperature measurement adjustable":"Yes; °C/°F/K","STEP 7 TIA Portal configurable/integrated from version":"V15 with HSP 265/integrated as of V15.1","Color code for module-specific color identification plate":"CC00","Between The Channels And The Power Supply Of The Electronics":"Yes","Interference voltage suppression for interference frequency f1 in Hz":"16.6 / 50 / 60 Hz / off","Permissible Input Voltage For Voltage Input (Destruction Limit), Max.":"30 V","Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)":"0.03 %","Series mode interference (peak value of interference < rated value of input range), min.":"70 dB"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$175.26 – $521.27","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c08539123e1f9d75ca69959985a865aa.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1124689&mlfb=6ES7134-6JD00-0DA1","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7134-6JD00-0DA1/alternatives.json"},"ai":{"faq":[{"question":"What thermocouple types does this module support?","answer":"It supports types B, C, E, J, K, L, N, R, S, T, and U, all at 16-bit resolution including sign."},{"question":"What is the maximum cable length for thermocouple inputs?","answer":"For thermocouples, shielded cable is limited to 100 m; for other signals it can be up to 200 m."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7134-6JD00-0DA1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7134-6JD00-0DA1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}