{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7134-6PA00-0BD0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7134-6PA00-0BD0","canonicalUrl":"https://aoctrl.com/siemens/6ES7134-6PA00-0BD0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7134-6PA00-0BD0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens ET 200SP analog input module for energy measurement, 20 mm, 100-240 V AC, BU type D0.","salesMarkdown":"The Siemens 6ES7134-6PA00-0BD0 is an ET 200SP analog input module dedicated to energy measurement — voltage, current, active/reactive power, and energy in a single 20 mm slice. It feeds on 100-240 V AC directly from the measured line (L1), eliminating a separate power supply. Mounted on a BU type D0 base unit, it fits any ET 200SP station. ## What it measures and how you set it up This module handles sinusoidal or distorted voltage curves and accepts current via an external CT (0.5 A secondary). It reports active power, reactive power, energy, frequency, and voltage — all cyclically and acyclically. Zero-point suppression is parameterizable from 20 to 250 mA (default 50 mA), useful for ignoring idle current on lightly loaded feeders. Firmware V2.0 supports I&M data records 0 through 3. Diagnostic alarms come standard; the green/red DIAG LED and red Fn LED per channel give quick fault isolation. No hardware interrupt or isochronous mode, but for standard sub-second energy monitoring that's not a gap. Mechanical coding on the module prevents plugging into the wrong base unit.","metaTitle":"Siemens 6ES7134-6PA00-0BD0 AI Energy, 20mm","metaDescription":"Siemens ET 200SP analog input module for energy measurement, 20 mm wide, 100-240 V AC, active & reactive power, I&M data. Current production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Analog Input Modules"],"specifications":{"Depth":"58 mm","Width":"20 mm","title":"6ES7134-6PA00-0BD0","Height":"73 mm","Present":"No","I&M data":"Yes; I&M0 to I&M3","description":"***Spare part*** SIMATIC ET 200SP, Analog input module, AI energy meter ST, suitable for BU type D0, channel diagnostics","Surge strength":"10 A; for 1 minute","Weight, approx.":"45 g","lifecycle_stage":"current","Diagnostic alarm":"Yes","Firmware version":"V2.0","Isochronous mode":"No","Parameter length":"38 byte","Power loss, typ.":"0.6 W","usable BaseUnits":"BU type D0","Limit value alarm":"No","Mounting position":"any","Power measurement":"Yes","Cyclic Measurement":"Yes","Energy measurement":"Yes","Hardware interrupt":"No","Acyclic Measurement":"Yes","Current measurement":"Yes","Voltage measurement":"Yes","Frequency measurement":"Yes","Isolation tested with":"2 300V AC for 1 min. (type test)","Channel status display":"Yes; green LED","Curve shape of voltage":"Sinusoidal or distorted","For Module Diagnostics":"Yes; green/red DIAG LED","Type of supply voltage":"100 - 240 V AC","Zero point suppression":"Parameterizable: 20 ... 250 mA, default 50 mA","For Channel Diagnostics":"Yes; red Fn LED","Active power measurement":"Yes","With Current Transformer":"Yes","With Voltage Transformer":"No","Fixed measured value sets":"Yes","Measured variable current":"0.5","Measured variable voltage":"0.5","Mechanical coding element":"Yes","Design of the power supply":"Supply via voltage measurement channel L1","Reactive power measurement":"Yes","Calibration possible in RUN":"No","Frequency measurement, max.":"65 Hz","Frequency measurement, min.":"45 Hz","Measured variable frequency":"0.05","Power consumption per phase":"20 mW","Vertical Installation, Max.":"50 °C","Vertical Installation, Min.":"0 °C","Without Current Transformer":"No","Acyclic measured value access":"Yes","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"0 °C","Measured variable phase angle":"±1 °; not covered by IEC 61557-12","Address space per module, max.":"44 byte; 32 byte input / 12 byte output","Measured variable active power":"1","Measured variable power factor":"0.5","Permissible Range, Lower Limit":"47 Hz","Permissible Range, Upper Limit":"63 Hz","Buffering of measured variables":"No","Cycle time (all channels), typ.":"50 ms; Time for consistent update of all measured and calculated values (cyclic und acyclic data)","Measured variable active energy":"1","Measured variable apparent power":"1","Measured variable reactive power":"1","Measured variable reactive energy":"2","Reparameterization possible in RUN":"Yes","Type of measured value acquisition":"seamless","permissible range, lower limit (AC)":"90 V","permissible range, upper limit (AC)":"264 V","Freely definable measured value sets":"No","Impulse voltage resistance 1,2/50μs":"1 kV","Between The Channels And Backplane Bus":"Yes; 3 700V AC (type test) CAT III","PROFIBUS from GSD version/GSD revision":"GSD Revision 5","PROFINET from GSD version/GSD revision":"V2.3","measurable relative current (AC), max.":"100 %; Relative to the secondary rated current; 1 A, 5 A","measurable relative current (AC), min.":"5 %; Relative to the secondary rated current; 1 A, 5 A","Bandwidth of measured value acquisition":"2 kHz; Harmonics: 39 / 50 Hz, 32 / 60 Hz","Input resistance measuring range 0 to 5 A":"25 mΩ","Monitoring of the supply voltage (PWR-LED)":"Yes","Burden power current transformer x/1A, min.":"As a function of cable length and cross section, see device manual","Burden power current transformer x/5A, min.":"As a function of cable length and cross section, see device manual","Measuring procedure for current measurement":"TRMS","Measuring procedure for voltage measurement":"TRMS","STEP 7 configurable/integrated from version":"V5.5 SP4 and higher","Continuous current with AC, maximum permissible":"5 A","Measurable line voltage between the line conductors":"400 V","STEP 7 TIA Portal configurable/integrated from version":"V13 SP1","Internal resistance line conductor and neutral conductor":"3.4 MΩ","Measurable line voltage between the line conductors, max.":"460 V","Measurable line voltage between the line conductors, min.":"155 V","Rated value short-time withstand current restricted to 1 s":"100 A","Measurable line voltage between phase and neutral conductor":"230 V","Apparent power consumption per phase for measuring range 5 A":"0.6 V·A","Measurable line voltage between phase and neutral conductor, max.":"264 V","Measurable line voltage between phase and neutral conductor, min.":"90 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$240.03 – $386.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e5444c2a6d45e12e1a825e1259ff12c7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=472927&mlfb=6ES7134-6PA00-0BD0"},"ai":{"faq":[{"question":"What base unit does this module require?","answer":"It requires a BU type D0 base unit, such as the 6ES7193-4CC30-0AA0."},{"question":"Does it measure active and reactive power?","answer":"Yes, it measures active power, reactive power, and energy, along with voltage, current, and frequency."},{"question":"What is the module's supply voltage?","answer":"It is powered directly from the measured voltage circuit: 100-240 V AC via the L1 channel."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7134-6PA00-0BD0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7134-6PA00-0BD0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}