{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7134-6PA00-0CU0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7134-6PA00-0CU0","canonicalUrl":"https://aoctrl.com/siemens/6ES7134-6PA00-0CU0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7134-6PA00-0CU0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens ET 200SP analog input module, 6ES7134-6PA00-0CU0, 4 AI 2-wire, 4x5 A, 230 V AC, width 20 mm.","salesMarkdown":"The Siemens 6ES7134-6PA00-0CU0 is an ET 200SP analog input module that measures four 2-wire current inputs, each rated up to 5 A at 230 V AC. Typical power draw sits at 1.4 W under full load. It occupies a single 20 mm-wide slot on a BU type U0 base unit. Firmware version V6.0 is loaded at the factory and can be updated in the field. The module reports I&M data up to I&M3 and generates diagnostic alarms, limit value alarms, and hardware interrupts for monitoring up to 16 freely selectable process values. Cable runs — shielded or unshielded — are limited to 200 m. ## Sourcing reality Availability is standard lead-time; we can quote against an RFQ for firm pricing and delivery. Because the module uses a BU type U0 base unit, make sure that base unit is also on the BOM — it's not the same as the BU type A0 or B0 used by other ET 200SP analog modules.","metaTitle":"Siemens 6ES7134-6PA00-0CU0 ET 200SP AI, 4x5 A, 230 V","metaDescription":"Siemens ET 200SP analog input module 6ES7134-6PA00-0CU0: 4 AI 2-wire, 5 A each, 1.4 W, 20 mm wide, current production. Order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Analog Input Modules"],"specifications":{"Depth":"58 mm","Width":"20 mm","Height":"73 mm","Inputs":"256 byte","Outputs":"20 byte","Present":"Yes","I&M data":"Yes; I&M0 to I&M3","Line quality":"Yes","Module fault":"Yes","Line analysis":"Yes","Voltage swell":"Yes","Shielded, Max.":"200 m","Supply voltage":"Yes","Surge strength":"10 A; for 1 minute","lifecycle_stage":"current","Diagnostic alarm":"Yes","Firmware version":"V6.0","Isochronous mode":"No","Overload current":"Yes","Parameter length":"128 byte","Power loss, typ.":"1.4 W; 4x 5 A input current, 3x 230 V AC","Unshielded, Max.":"200 m","usable BaseUnits":"BU type U0","2-Wire Connection":"BU type U0","Limit value alarm":"Yes","Mounting position":"any","Power measurement":"Yes","Voltage dip (DIP)":"Yes","Automatic encoding":"Yes","Energy measurement":"Yes","FW update possible":"Yes","Hardware interrupt":"Yes; Monitoring of up to 16 freely selectable process values (exceeding or undershooting of value)","Overflow/underflow":"Yes","With Rogowski coil":"No","Current measurement":"Yes","Voltage measurement":"Yes","Between The Channels":"No","Secondary side, max.":"300 V","Channel not available":"Yes","Frequency measurement":"Yes","Isolation tested with":"Between channels and backplane bus, 24 V supply: Routine test, 1 920 V AC, 2 s; between backplane bus and 24 V supply: Type test, 707 V DC","Channel status display":"Yes; green LED","Curve shape of voltage":"Sinusoidal or distorted","For Module Diagnostics":"Yes; green/red DIAG LED","Measured variable THDI":"1","Measured variable THDU":"1","Zero point suppression":"0 ... 20%, referred to the nominal current","For Channel Diagnostics":"Yes; red Fn LED","Hardware interrupt lost":"Yes","Active power measurement":"Yes","Power factor measurement":"Yes","Sampling frequency, max.":"2 048 kHz","With Current Transformer":"Yes; 1 A or 5 A current transformer","With Voltage Transformer":"Yes","Active factor measurement":"Yes","Current consumption, max.":"17 mA","Fixed measured value sets":"Yes","Measured variable current":"Class S","Measured variable voltage":"Class S","Mechanical coding element":"Yes","Design of the power supply":"DC","Measured variable harmonic":"1","Parameter assignment error":"Yes","Reactive power measurement":"Yes","Calibration possible in RUN":"Yes","Frequency measurement, max.":"65 Hz","Frequency measurement, min.":"45 Hz","Measured variable frequency":"Class S","Power consumption per phase":"60 mW; 300 V AC","Reactive power compensation":"Yes","Vertical Installation, Max.":"50 °C","Vertical Installation, Min.":"0 °C; On request: Ambient temperatures lower than 0 °C (without condensation)","Without Current Transformer":"No","Without Voltage Transformer":"Yes","Cyclic measured value access":"Yes","Acyclic measured value access":"Yes","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"0 °C; On request: Ambient temperatures lower than 0 °C (without condensation)","Measured variable phase angle":"±0.5 °; not covered by IEC 61557-12","Measured variable active power":"0.5","Measured variable power factor":"0.5","Supported power supply systems":"TT, TN, IT","With current-voltage-converter":"No","Buffering of measured variables":"Yes","Cycle time (all channels), typ.":"50 ms; Time for consistent update of all measured and calculated values (cyclic und acyclic data)","Measured variable active energy":"0.5","Measured variable apparent power":"0.5","Measured variable reactive power":"1","Current consumption (rated value)":"12.5 mA","Harmonics for current and voltage":"Yes","Measured variable neutral current":"0,2","Measured variable reactive energy":"1","Measured variable harmonic current":"Class S","Measured variable harmonic voltage":"Class S","Reparameterization possible in RUN":"Yes","Type of measured value acquisition":"seamless","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Freely definable measured value sets":"Yes; For cyclic and acyclic measured value access","Impulse voltage resistance 1,2/50μs":"2.5 kV","Between The Channels And Backplane Bus":"Yes","Measured variable voltage interruption":"Class S","PROFIBUS from GSD version/GSD revision":"One GSD file each, Revision 3 and 5 and higher","PROFINET from GSD version/GSD revision":"V2.3","measurable relative current (AC), max.":"100 %; Relative to the secondary rated current 5 A","measurable relative current (AC), min.":"1 %; Relative to the secondary rated current 5 A","Bandwidth of measured value acquisition":"3.2 kHz; Harmonics: 63 / 50 Hz, 52 / 60 Hz","Measured variable voltage dip and swell":"Class S","THD measurement for current and voltage":"Yes","Between the channels and load voltage L+":"Yes; Including FE","Switching between operating modes in RUN":"Yes; For module version 32 I/20 Q, it is possible to dynamically switch between 25 user data variants, 23 of which are pre-defined and 2 of which can be defined by the specific user","Input resistance measuring range 0 to 5 A":"25 mΩ; At the terminal","Monitoring of the supply voltage (PWR-LED)":"Yes","Burden power current transformer x/1A, min.":"As a function of cable length and cross section, see device manual","Burden power current transformer x/5A, min.":"As a function of cable length and cross section, see device manual","Installation altitude above sea level, max.":"3 000 m; Restrictions for installation altitudes > 2 000 m, see manual","Measuring procedure for current measurement":"TRMS","Measuring procedure for voltage measurement":"TRMS","STEP 7 configurable/integrated from version":"V5.5 SP3 or higher","Continuous current with AC, maximum permissible":"5 A; 6 A permanent thermal overload","Monitoring of instantaneous and half-wave values":"Yes","Measurable line voltage between the line conductors":"519 V","STEP 7 TIA Portal configurable/integrated from version":"STEP 7 V15 or higher","Internal resistance line conductor and neutral conductor":"1.5 MΩ","Color code for module-specific color identification plate":"CC20","Measurable line voltage between the line conductors, max.":"519 V","Measurable line voltage between the line conductors, min.":"6 V","Rated value short-time withstand current restricted to 1 s":"100 A","Measurable line voltage between phase and neutral conductor":"300 V","Apparent power consumption per phase for measuring range 5 A":"0.6 VA","Measurable line voltage between phase and neutral conductor, max.":"300 V","Measurable line voltage between phase and neutral conductor, min.":"3 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/432c487c186e2530139175cfbba4dd00.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1123853&mlfb=6ES7134-6PA00-0CU0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7134-6PA00-0CU0/alternatives.json"},"ai":{"faq":[{"question":"What are the physical dimensions of 6ES7134-6PA00-0CU0?","answer":"Width 20 mm, height 73 mm, depth 58 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7134-6PA00-0CU0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7134-6PA00-0CU0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}