{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7134-6PA01-0BD0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7134-6PA01-0BD0","canonicalUrl":"https://aoctrl.com/siemens/6ES7134-6PA01-0BD0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7134-6PA01-0BD0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens ET 200SP analog input module, 6ES7134-6PA01-0BD0, 20 mm width, 58 mm depth, BU type D0, 100-240 V AC supply, firmware V3.0.","salesMarkdown":"## 20 mm slice, BU D0 — what it fits The 6ES7134-6PA01-0BD0 is a 20 mm wide analog input module for the Siemens ET 200SP distributed I/O system. It requires a BU type D0 base unit (the dark-colored one) — the module won't seat in a BU type A0 or B0. Depth is 58 mm, so it sits flush in a standard ET 200SP assembly with no overhang past the base unit. Mounting position is unrestricted. ## Voltage, current, power — one module covers the three-phase panel This module measures voltage, current, active power, reactive power, frequency, and energy in a single slice — no separate transducer needed. It accepts 100-240 V AC on the measurement input and is designed for sinusoidal or distorted waveforms. The power supply is drawn from the voltage measurement channel, so no separate auxiliary feed is required. Zero point suppression is parameterizable from 20 to 250 mA (default 50 mA) — useful for ignoring idle current on lightly loaded feeders. Diagnostic and channel alarms are supported, with a green/red DIAG LED and a red Fn LED per channel. Firmware is V3.0.","metaTitle":"Siemens 6ES7134-6PA01-0BD0 Analog Input Module, 20 mm, BU D0","metaDescription":"Siemens 6ES7134-6PA01-0BD0 analog input module, 20 mm wide, 58 mm deep. Requires BU type D0 base unit.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Analog Input Modules"],"specifications":{"Depth":"58 mm","Width":"20 mm","Height":"73 mm","Present":"No","I&M data":"Yes; I&M0 to I&M3","Surge strength":"10 A; for 1 minute","Weight, approx.":"45 g","lifecycle_stage":"current","Diagnostic alarm":"Yes","Firmware version":"V3.0","Isochronous mode":"No","Parameter length":"38 byte","Power loss, typ.":"0.6 W","Rated value (AC)":"100 - 240 V AC","usable BaseUnits":"BU type D0","Limit value alarm":"No","Mounting position":"any","Power measurement":"Yes","Cyclic Measurement":"Yes","Energy measurement":"Yes","Hardware interrupt":"No","Acyclic Measurement":"Yes","Current measurement":"Yes","Voltage measurement":"Yes","Frequency measurement":"Yes","Isolation tested with":"2 300V AC for 1 min. (type test)","Channel status display":"Yes; green LED","Curve shape of voltage":"Sinusoidal or distorted","For Module Diagnostics":"Yes; green/red DIAG LED","Zero point suppression":"Parameterizable: 20 ... 250 mA, default 50 mA","For Channel Diagnostics":"Yes; red Fn LED","Active power measurement":"Yes","With Current Transformer":"Yes","With Voltage Transformer":"No","Fixed measured value sets":"Yes","Measured variable current":"0.5","Measured variable voltage":"0.5","Mechanical coding element":"Yes","Design of the power supply":"Supply via voltage measurement channel L1","Reactive power measurement":"Yes","Calibration possible in RUN":"No","Frequency measurement, max.":"65 Hz","Frequency measurement, min.":"45 Hz","Measured variable frequency":"0.05","Power consumption per phase":"20 mW","Vertical Installation, Max.":"50 °C","Vertical Installation, Min.":"0 °C","Without Current Transformer":"No","Acyclic measured value access":"Yes","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"0 °C","Measured variable phase angle":"±1 °; not covered by IEC 61557-12","Address space per module, max.":"44 byte; 32 byte input / 12 byte output","Measured variable active power":"1","Measured variable power factor":"0.5","Permissible Range, Lower Limit":"47 Hz","Permissible Range, Upper Limit":"63 Hz","Buffering of measured variables":"No","Cycle time (all channels), typ.":"50 ms; Time for consistent update of all measured and calculated values (cyclic und acyclic data)","Measured variable active energy":"1","Measured variable apparent power":"1","Measured variable reactive power":"1","Measured variable reactive energy":"2","Type of mechanical coding element":"type C","Reparameterization possible in RUN":"Yes","Type of measured value acquisition":"seamless","permissible range, lower limit (AC)":"90 V","permissible range, upper limit (AC)":"264 V","Freely definable measured value sets":"No","Impulse voltage resistance 1,2/50μs":"1 kV","Between The Channels And Backplane Bus":"Yes; 3 700V AC (type test) CAT III","PROFIBUS from GSD version/GSD revision":"GSD Revision 5","PROFINET from GSD version/GSD revision":"V2.3","measurable relative current (AC), max.":"100 %; Relative to the secondary rated current; 1 A, 5 A","measurable relative current (AC), min.":"5 %; Relative to the secondary rated current; 1 A, 5 A","Bandwidth of measured value acquisition":"2 kHz; Harmonics: 39 / 50 Hz, 32 / 60 Hz","Input resistance measuring range 0 to 5 A":"25 mΩ; At the terminal","Monitoring of the supply voltage (PWR-LED)":"Yes","Burden power current transformer x/1A, min.":"As a function of cable length and cross section, see device manual","Burden power current transformer x/5A, min.":"As a function of cable length and cross section, see device manual","Measuring procedure for current measurement":"TRMS","Measuring procedure for voltage measurement":"TRMS","STEP 7 configurable/integrated from version":"V5.5 SP4 and higher","Continuous current with AC, maximum permissible":"5 A","Measurable line voltage between the line conductors":"400 V","STEP 7 TIA Portal configurable/integrated from version":"V13 SP1","Internal resistance line conductor and neutral conductor":"3.4 MΩ","Measurable line voltage between the line conductors, max.":"460 V","Measurable line voltage between the line conductors, min.":"155 V","Rated value short-time withstand current restricted to 1 s":"100 A","Measurable line voltage between phase and neutral conductor":"230 V","Apparent power consumption per phase for measuring range 5 A":"0.6 VA","Measurable line voltage between phase and neutral conductor, max.":"264 V","Measurable line voltage between phase and neutral conductor, min.":"90 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$335.28 – $690.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c18af1b7838a316add24e1f5797f4e30.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=649136&mlfb=6ES7134-6PA01-0BD0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7134-6PA01-0BD0/alternatives.json"},"ai":{"faq":[{"question":"What base unit is required for Siemens 6ES7134-6PA01-0BD0?","answer":"Requires a BU type D0 base unit. It will not fit a BU type A0 or B0 base unit."},{"question":"Does 6ES7134-6PA01-0BD0 support diagnostic alarms?","answer":"Yes. The module supports diagnostic alarms and channel diagnostics, with a green/red DIAG LED and a red Fn LED per channel."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7134-6PA01-0BD0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7134-6PA01-0BD0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}