{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7134-6PA01-0BU0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7134-6PA01-0BU0","canonicalUrl":"https://aoctrl.com/siemens/6ES7134-6PA01-0BU0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7134-6PA01-0BU0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens ET 200SP power measurement module, 6ES7134-6PA01-0BU0, 24 V DC, 58 mm depth, width 20 mm, height 73 mm, current production.","salesMarkdown":"## Module overview It measures current on up to three phases plus neutral, along with voltage, frequency, power, and energy. Firmware version V8.0 is shipped from the factory, matching TIA Portal libraries at that revision. ## I/O and diagnostics The module provides 256 bytes of input data and 20 bytes of output data. It supports I&M data (I&M0 to I&M3) for asset tracking, diagnostic alarm, limit value alarm, and hardware interrupt (monitoring up to 16 freely selectable process values). Overflow/underflow detection and channel-not-available handling are built in. Base unit type U0 is required; this module works only with BU type U0 in 2-wire connection. Maximum cable length is 200 m for both shielded and unshielded runs. Isolation is tested at 1 920 V AC for 2 s between channels and backplane/24 V supply, and 707 V DC between backplane and 24 V supply. Power loss is typically 1 W under a 3x 5 A input at 230 V AC load. Firmware can be updated in the field, and automatic encoding simplifies replacement without manual address assignment. Isochronous mode is not supported — this module uses the standard ET 200SP backplane communication.","metaTitle":"Siemens 6ES7134-6PA01-0BU0 Power Measurement Module, 24 V","metaDescription":"Current-production Siemens ET 200SP power measurement module. 24 V DC supply, 58 mm depth, 20 mm width. Measures current, voltage, frequency, power, energy. Firmware V8.0 with diag","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Analog Input Modules"],"specifications":{"Depth":"58 mm","Width":"20 mm","title":"6ES7134-6PA01-0BU0","Height":"73 mm","Inputs":"256 byte","Outputs":"20 byte","Present":"Yes","I&M data":"Yes; I&M0 to I&M3","description":"SIMATIC ET 200SP, analog input module, AI Energy Meter CT ST, for 1A or 5A current transformer, suitable for BU type U0, channel diagnostics","Module fault":"Yes","Line analysis":"No","Shielded, Max.":"200 m","Supply voltage":"Yes","Surge strength":"10 A; for 1 minute","Weight, approx.":"45 g","lifecycle_stage":"current","Diagnostic alarm":"Yes","Firmware version":"V8.0","Isochronous mode":"No","Overload current":"Yes","Parameter length":"128 byte","Power loss, typ.":"1 W; 3x 5 A input current, 3x 230 V AC","Rated value (DC)":"24 V","Unshielded, Max.":"200 m","usable BaseUnits":"BU type U0","2-Wire Connection":"BU type U0","Limit value alarm":"Yes","Mounting position":"any","Power measurement":"Yes","Automatic encoding":"Yes","Energy measurement":"Yes","FW update possible":"Yes","Hardware interrupt":"Yes; Monitoring of up to 16 freely selectable process values (exceeding or undershooting of value)","Overflow/underflow":"Yes","With Rogowski coil":"No","Current measurement":"Yes; max. 3 + neutral conductor","Voltage measurement":"Yes","Between The Channels":"No","Secondary side, max.":"300 V","Channel not available":"Yes","Frequency measurement":"Yes","Isolation tested with":"Between channels and backplane bus, 24 V supply: Routine test, 1 920 V AC, 2 s; between backplane bus and 24 V supply: Type test, 707 V DC","Channel status display":"Yes; green LED","Curve shape of voltage":"Sinusoidal or distorted","For Module Diagnostics":"Yes; green/red DIAG LED","Zero point suppression":"0 ... 20%, referred to the nominal current","For Channel Diagnostics":"Yes; red Fn LED","Hardware interrupt lost":"Yes","Active power measurement":"Yes","Power factor measurement":"Yes","Sampling frequency, max.":"2 048 kHz","With Current Transformer":"Yes; 1 A or 5 A current transformer","With Voltage Transformer":"Yes","Active factor measurement":"Yes","Current consumption, max.":"17 mA","Fixed measured value sets":"Yes","Measured variable current":"0,2","Measured variable voltage":"0,2","Mechanical coding element":"Yes","Parameter assignment error":"Yes","Reactive power measurement":"Yes","Calibration possible in RUN":"Yes","Frequency measurement, max.":"70 Hz","Frequency measurement, min.":"40 Hz","Measured variable frequency":"0.05; only valid for the permissible voltage measuring range","Power consumption per phase":"60 mW; 300 V AC","Reactive power compensation":"Yes","Vertical Installation, Max.":"50 °C","Vertical Installation, Min.":"-30 °C","Without Current Transformer":"No","Without Voltage Transformer":"Yes","Cyclic measured value access":"Yes","Acyclic measured value access":"Yes","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"-30 °C","Measured variable phase angle":"±0.5 °; not covered by IEC 61557-12","Measured variable active power":"0.5","Measured variable power factor":"0.5","Supported power supply systems":"TT, TN, IT","With current-voltage-converter":"No","Buffering of measured variables":"Yes","Cycle time (all channels), typ.":"50 ms; Time for consistent update of all measured and calculated values (cyclic und acyclic data)","Measured variable active energy":"0.5","Measured variable apparent power":"0.5","Measured variable reactive power":"1","Current consumption (rated value)":"12.5 mA","Measured variable neutral current":"0,2","Measured variable reactive energy":"1","Type of mechanical coding element":"type C","Reparameterization possible in RUN":"Yes","Type of measured value acquisition":"seamless","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Freely definable measured value sets":"Yes; For cyclic and acyclic measured value access","Impulse voltage resistance 1,2/50μs":"2.5 kV","Between The Channels And Backplane Bus":"Yes","PROFIBUS from GSD version/GSD revision":"One GSD file each, Revision 3 and 5 and higher","PROFINET from GSD version/GSD revision":"V2.3","measurable relative current (AC), max.":"100 %; Relative to the secondary rated current 5 A","measurable relative current (AC), min.":"1 %; Relative to measuring range; 1 A, 5 A","Bandwidth of measured value acquisition":"3.2 kHz; Harmonics: 63 / 50 Hz, 52 / 60 Hz","Between the channels and load voltage L+":"Yes; Including FE","Switching between operating modes in RUN":"Yes; For module version 32 I/20 Q, it is possible to dynamically switch between 25 user data variants, 23 of which are pre-defined and 2 of which can be defined by the specific user","Input resistance measuring range 0 to 5 A":"25 mΩ; At the terminal","Monitoring of the supply voltage (PWR-LED)":"Yes","Burden power current transformer x/1A, min.":"As a function of cable length and cross section, see device manual","Burden power current transformer x/5A, min.":"As a function of cable length and cross section, see device manual","Installation altitude above sea level, max.":"3 000 m; Restrictions for installation altitudes > 2 000 m, see manual","Measuring procedure for current measurement":"TRMS","Measuring procedure for voltage measurement":"TRMS","STEP 7 configurable/integrated from version":"Configurable via GSD file","Continuous current with AC, maximum permissible":"5 A","Measurable line voltage between the line conductors":"480 V","STEP 7 TIA Portal configurable/integrated from version":"STEP 7 V16 or higher with HSP","Internal resistance line conductor and neutral conductor":"1.5 MΩ","Color code for module-specific color identification plate":"CC20","Measurable line voltage between the line conductors, max.":"519 V","Measurable line voltage between the line conductors, min.":"6 V","Rated value short-time withstand current restricted to 1 s":"100 A","Measurable line voltage between phase and neutral conductor":"277 V","Apparent power consumption per phase for measuring range 5 A":"0.6 VA","Measurable line voltage between phase and neutral conductor, max.":"300 V","Measurable line voltage between phase and neutral conductor, min.":"3 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$144.78 – $428.37","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d15309b214ed937c2e419ef7176fc557.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1440330&mlfb=6ES7134-6PA01-0BU0"},"ai":{"faq":[{"question":"What is the depth of this module?","answer":"The depth is 58 mm."},{"question":"What is the width of this module?","answer":"The width is 20 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7134-6PA01-0BU0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7134-6PA01-0BU0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}