{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7134-6PA20-0BD0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7134-6PA20-0BD0","canonicalUrl":"https://aoctrl.com/siemens/6ES7134-6PA20-0BD0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7134-6PA20-0BD0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC ET 200SP, analog input module, AI Energy Meter 480V AC, 256 byte inputs, 12 byte outputs, 0.6 W power loss, 58 mm depth, 20 mm width, 73 mm height.","salesMarkdown":"## 256-byte I/O map, 20 mm wide — what fits in the ET 200SP slot The Siemens 6ES7134-6PA20-0BD0 is an AI Energy Meter module for the SIMATIC ET 200SP distributed I/O system. It occupies one 20 mm-wide BaseUnit slot (BU type D0) and draws 256 input bytes and 12 output bytes from the backplane — that's the full I/O map for a three-phase power measurement channel with voltage, current, and frequency capture. Rated for AC 100–277 V line-to-neutral, it measures sinusoidal or distorted waveforms via a sigma-delta ADC. The 0.6 W typical power loss stays cool in a densely packed ET 200SP station — no derating needed for adjacent modules. The 58 mm depth and 20 mm width match the standard ET 200SP footprint — snaps onto a BU type D0 BaseUnit (order separately). Mounting position is any orientation, so it fits horizontal or vertical DIN-rail layouts without clearance concerns. Unshielded cable runs up to 200 m are allowed for the voltage inputs — the sigma-delta measurement principle rejects common-mode noise well enough that a shielded run isn't mandatory in a clean panel. For noisy environments (VFD cabinets, welding lines), shielded twisted-pair is still the safer bet. Zero-point suppression is parameterizable from 2 to 250 mA (default 50 mA) — useful for ignoring transformer magnetising current or light-load leakage on a motor feeder. The hardware interrupt monitors up to 16 freely selectable process values for over/undershoot, so the PLC can trip on a current spike without polling the I/O map. ## Diagnostic and alarm coverage Diagnostic alarm, limit value alarm, and channel diagnostics (red Fn LED) are all present. The green DIAG LED reports module status; the green channel LED shows per-channel activity. I&M data (I&M0 to I&M3) is supported for asset tracking in TIA Portal. Isolation tested at 2300 V AC for 1 minute (type test) between the secondary side and the backplane — sufficient for 480 V line-to-line systems. Surge strength is 10 A for 1 minute.","metaTitle":"Siemens 6ES7134-6PA20-0BD0 Analog Input Module, 58 mm","metaDescription":"Siemens 6ES7134-6PA20-0BD0 analog input module, 256 byte inputs, 12 byte outputs, 0.6 W loss. Current production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Analog Input Modules"],"specifications":{"Depth":"58 mm","Width":"20 mm","Height":"73 mm","Inputs":"256 byte","Outputs":"12 byte","Present":"Yes","I&M data":"Yes; I&M0 to I&M3","Line analysis":"No","Surge strength":"10 A; for 1 minute","Weight, approx.":"45 g","lifecycle_stage":"current","Diagnostic alarm":"Yes","Firmware version":"V4.0","Isochronous mode":"No","Parameter length":"74 byte","Power loss, typ.":"0.6 W","Rated value (AC)":"AC 100 - 277 V","Unshielded, Max.":"200 m","usable BaseUnits":"BU type D0","2-Wire Connection":"BU type D0, BU20-P12+A0+0B","Limit value alarm":"Yes","Mounting position":"any","Power measurement":"Yes","Automatic encoding":"Yes","Energy measurement":"Yes","FW update possible":"Yes","Hardware interrupt":"Yes; Monitoring of up to 16 freely selectable process values (exceeding or undershooting of value)","With Rogowski coil":"No","Current measurement":"Yes","Voltage measurement":"Yes","Between The Channels":"No","Secondary side, max.":"296 V","Frequency measurement":"Yes","Isolation tested with":"2 300V AC for 1 min. (type test)","Measurement principle":"Sigma Delta","Channel status display":"Yes; green LED","Curve shape of voltage":"Sinusoidal or distorted","For Module Diagnostics":"Yes; green/red DIAG LED","Zero point suppression":"Parameterizable: 2 ... 250 mA, default 50 mA","For Channel Diagnostics":"Yes; red Fn LED","Active power measurement":"Yes","Power factor measurement":"Yes","Sampling frequency, max.":"1 024 kHz","With Current Transformer":"Yes","With Voltage Transformer":"Yes","Active factor measurement":"No","Fixed measured value sets":"Yes","Measured variable current":"0,2","Measured variable voltage":"0,2","Mechanical coding element":"Yes","Design of the power supply":"Supply via voltage measurement channel L1","Reactive power measurement":"Yes","Calibration possible in RUN":"Yes","Frequency measurement, max.":"65 Hz","Frequency measurement, min.":"45 Hz","Measured variable frequency":"0.05","Power consumption per phase":"20 mW","Reactive power compensation":"No","Vertical Installation, Max.":"50 °C","Vertical Installation, Min.":"0 °C","Without Current Transformer":"No","Without Voltage Transformer":"Yes","Cyclic measured value access":"Yes","Acyclic measured value access":"Yes","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"0 °C","Measured variable phase angle":"±1 °; not covered by IEC 61557-12","Measured variable active power":"0.5","Measured variable power factor":"0.5","Permissible Range, Lower Limit":"47 Hz","Permissible Range, Upper Limit":"63 Hz","Supported power supply systems":"TT, TN","With current-voltage-converter":"No","Buffering of measured variables":"Yes","Cycle time (all channels), typ.":"50 ms; Time for consistent update of all measured and calculated values (cyclic und acyclic data)","Measured variable active energy":"0.5","Measured variable apparent power":"0.5","Measured variable reactive power":"1","Measured variable neutral current":"0.5; calculated","Measured variable reactive energy":"1","Type of mechanical coding element":"type C","Reparameterization possible in RUN":"Yes","Type of measured value acquisition":"seamless","permissible range, lower limit (AC)":"90 V","permissible range, upper limit (AC)":"293 V","Freely definable measured value sets":"Yes","Impulse voltage resistance 1,2/50μs":"1 kV","Between The Channels And Backplane Bus":"Yes; 3 700V AC (type test) CAT III","PROFIBUS from GSD version/GSD revision":"GSD Revision 5","PROFINET from GSD version/GSD revision":"V2.3","measurable relative current (AC), max.":"100 %; Relative to the secondary rated current 5 A","measurable relative current (AC), min.":"1 %; Relative to the secondary rated current 5 A","Bandwidth of measured value acquisition":"2 kHz; Harmonics: 39 / 50 Hz, 32 / 60 Hz","Input resistance measuring range 0 to 5 A":"25 mΩ; At the terminal","Monitoring of the supply voltage (PWR-LED)":"Yes","Burden power current transformer x/1A, min.":"As a function of cable length and cross section, see device manual","Burden power current transformer x/5A, min.":"As a function of cable length and cross section, see device manual","Measuring procedure for current measurement":"TRMS","Measuring procedure for voltage measurement":"TRMS","STEP 7 configurable/integrated from version":"V5.5 SP4 and higher","Continuous current with AC, maximum permissible":"5 A","Measurable line voltage between the line conductors":"480 V","Ambient air temperature-barometric pressure-altitude":"On request: Ambient temperatures lower than 0 °C (without condensation) and/or installation altitudes greater than 2 000 m","STEP 7 TIA Portal configurable/integrated from version":"V13 SP1","Internal resistance line conductor and neutral conductor":"3.4 MΩ","Measurable line voltage between the line conductors, max.":"508 V","Measurable line voltage between the line conductors, min.":"155 V","Rated value short-time withstand current restricted to 1 s":"100 A","Measurable line voltage between phase and neutral conductor":"277 V","Apparent power consumption per phase for measuring range 5 A":"0.6 VA","Measurable line voltage between phase and neutral conductor, max.":"293 V","Measurable line voltage between phase and neutral conductor, min.":"90 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$345.00 – $513.42","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ee448ef30240ba27d52ffb7994547625.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=649137&mlfb=6ES7134-6PA20-0BD0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7134-6PA20-0BD0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7134-6PA20-0BD0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7134-6PA20-0BD0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}