{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7134-6PA20-0CU0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7134-6PA20-0CU0","canonicalUrl":"https://aoctrl.com/siemens/6ES7134-6PA20-0CU0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7134-6PA20-0CU0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens ET 200SP analog input module, AI Energy Meter 400VAC ST, 6ES7134-6PA20-0CU0, 24 V DC supply, 300 V secondary, 0.4 W power loss.","salesMarkdown":"The 6ES7134-6PA20-0CU0: The module draws 0.4 W typ. from the backplane, which leaves generous headroom in the ET 200SP power budget for additional slices. Diagnostic coverage includes overload, undervoltage/overvoltage (voltage swell and dip), line quality analysis, module fault, and a hardware interrupt that monitors up to 16 freely selectable process values for exceeding or undershooting limits. Firmware updates are possible via the backplane bus, and the HW functional state starts at FS02. Mechanical: 20 mm wide, 73 mm high, 58 mm deep. Mounts on a BU type U0 base unit; any mounting position is acceptable. Wiring: shielded cables up to 200 m or unshielded up to 30 m. The module uses 2-wire connection per the BU U0 pinout. Automatic encoding of the base unit is supported. I&M data is supported from I&M0 to I&M3 for asset tracking.","metaTitle":"Siemens 6ES7134-6PA20-0CU0 AI Energy Meter, 24 V DC","metaDescription":"Active current production analog input module for ET 200SP. Rated 24 V DC supply, 300 V secondary, 0.4 W power loss. Order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Analog Input Modules"],"specifications":{"Depth":"58 mm","Width":"20 mm","title":"6ES7134-6PA20-0CU0","Height":"73 mm","Inputs":"256 byte","Outputs":"20 byte","Present":"Yes","I&M data":"Yes; I&M0 to I&M3","description":"*** spare part *** SIMATIC ET 200SP, analog input module, AI Energy Meter 480V AC/RC HF for Rogowski-coils, current/voltage transformer 333 mV, with network analysis functions, suitable for BU type U0, channel diagnostics","Line quality":"Yes","Module fault":"Yes","Line analysis":"Yes","Voltage swell":"Yes","Shielded, Max.":"200 m","Supply voltage":"Yes","Weight, approx.":"45 g","lifecycle_stage":"current","Diagnostic alarm":"Yes","Input resistance":"120 kΩ","Isochronous mode":"No","Overload current":"Yes","Parameter length":"128 byte","Power loss, typ.":"0.4 W; 3x 230 V AC","Rated value (DC)":"24 V","Unshielded, Max.":"30 m","usable BaseUnits":"BU type U0","2-Wire Connection":"BU type U0","Limit value alarm":"Yes","Mounting position":"any","Power measurement":"Yes","Voltage dip (DIP)":"Yes","Automatic encoding":"Yes","Energy measurement":"Yes","FW update possible":"Yes","Hardware interrupt":"Yes; Monitoring of up to 16 freely selectable process values (exceeding or undershooting of value)","Overflow/underflow":"Yes","With Rogowski coil":"Yes","Current measurement":"Yes","Voltage measurement":"Yes","Between The Channels":"No","HW functional status":"From FS02","Secondary side, max.":"300 V","Channel not available":"Yes","Frequency measurement":"Yes","Isolation tested with":"Between channels and backplane bus, 24 V supply: Routine test, 1 920 V AC, 2 s; between backplane bus and 24 V supply: Type test, 707 V DC","Channel status display":"Yes; green LED","Curve shape of voltage":"Sinusoidal or distorted","For Module Diagnostics":"Yes; green/red DIAG LED","Measured variable THDI":"1","Measured variable THDU":"1","Zero point suppression":"Yes; 0 ... 20%, referred to the nominal current","For Channel Diagnostics":"Yes; red Fn LED","Hardware interrupt lost":"Yes","Active power measurement":"Yes","Power factor measurement":"Yes","Sampling frequency, max.":"2 048 kHz","With Current Transformer":"No","With Voltage Transformer":"Yes","Active factor measurement":"Yes","Current consumption, max.":"17 mA","Fixed measured value sets":"Yes","Measured variable current":"Class S","Measured variable voltage":"Class S","Mechanical coding element":"Yes","Measured variable harmonic":"1","Parameter assignment error":"Yes","Reactive power measurement":"Yes","Calibration possible in RUN":"Yes","Frequency measurement, max.":"65 Hz","Frequency measurement, min.":"45 Hz","Measured variable frequency":"Class S","Power consumption per phase":"60 mW; 300 V AC","Reactive power compensation":"Yes","Vertical Installation, Max.":"50 °C","Vertical Installation, Min.":"-30 °C; < 0 °C as of FS02","Without Current Transformer":"No","Without Voltage Transformer":"Yes","Cyclic measured value access":"Yes","Acyclic measured value access":"Yes","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"-30 °C; < 0 °C as of FS02","Measured variable phase angle":"±0.5 °; not covered by IEC 61557-12","Measurable current at AC, max.":"424 mV","Measured variable active power":"0.5","Measured variable power factor":"0.5","Supported power supply systems":"TT, TN, IT","With current-voltage-converter":"Yes; 333 mV interface","Buffering of measured variables":"Yes","Cycle time (all channels), typ.":"50 ms; Time for consistent update of all measured and calculated values (cyclic und acyclic data)","Measured variable active energy":"0.5","Measured variable apparent power":"0.5","Measured variable reactive power":"1","Current consumption (rated value)":"12.5 mA","Harmonics for current and voltage":"Yes","Measured variable neutral current":"0,2","Measured variable reactive energy":"1","Type of mechanical coding element":"type C","Measured variable harmonic current":"Class S","Measured variable harmonic voltage":"Class S","Reparameterization possible in RUN":"Yes","Type of measured value acquisition":"seamless","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Freely definable measured value sets":"Yes; For cyclic and acyclic measured value access","Impulse voltage resistance 1,2/50μs":"2.5 kV","Between The Channels And Backplane Bus":"Yes","Measured variable voltage interruption":"Class S","PROFIBUS from GSD version/GSD revision":"One GSD file each, Revision 3 and 5 and higher","PROFINET from GSD version/GSD revision":"V2.3","Bandwidth of measured value acquisition":"3.2 kHz; Harmonics: 63 / 50 Hz, 52 / 60 Hz","Continuous voltage, maximum permissible":"2 V","Measured variable voltage dip and swell":"Class S","THD measurement for current and voltage":"Yes","Between the channels and load voltage L+":"Yes; Including FE","Switching between operating modes in RUN":"Yes; For module version 32 I/20 Q, it is possible to dynamically switch between 25 user data variants, 23 of which are pre-defined and 2 of which can be defined by the specific user","Monitoring of the supply voltage (PWR-LED)":"Yes","Installation altitude above sea level, max.":"3 000 m; Restrictions for installation altitudes > 2 000 m, see manual","Measuring procedure for current measurement":"TRMS","Measuring procedure for voltage measurement":"TRMS","STEP 7 configurable/integrated from version":"V5.5 SP3 or higher","Monitoring of instantaneous and half-wave values":"Yes","Measurable line voltage between the line conductors":"519 V","STEP 7 TIA Portal configurable/integrated from version":"STEP 7 V15 or higher","Internal resistance line conductor and neutral conductor":"1.5 MΩ","Color code for module-specific color identification plate":"CC20","Measurable line voltage between the line conductors, max.":"519 V","Measurable line voltage between the line conductors, min.":"6 V","Measurable line voltage between phase and neutral conductor":"300 V","Rated value, short-time withstand voltage restricted to 1 s":"30 V","Measurable line voltage between phase and neutral conductor, max.":"300 V","Measurable line voltage between phase and neutral conductor, min.":"3 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3887020388cefac1873f7ccf52bb8bb4.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1123854&mlfb=6ES7134-6PA20-0CU0"},"ai":{"faq":[{"question":"What are the physical dimensions of the module?","answer":"The module measures 20 mm wide, 73 mm high, and 58 mm deep."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7134-6PA20-0CU0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7134-6PA20-0CU0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}