{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7134-6PA21-0BU0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7134-6PA21-0BU0","canonicalUrl":"https://aoctrl.com/siemens/6ES7134-6PA21-0BU0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7134-6PA21-0BU0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens ET 200SP AI Energy Meter module, 6ES7134-6PA21-0BU0, 58 mm depth, 20 mm width, 24 V DC, firmware V8.0.","salesMarkdown":"The Siemens 6ES7134-6PA21-0BU0 is an ET 200SP AI Energy Meter module that measures voltage, current, power, and energy on a per-phase basis for 3-phase systems plus neutral. It accepts 256 bytes of input data and delivers 20 bytes of output data, communicating over the ET 200SP backplane at firmware V8.0. ## Kit completeness check The module is supplied alone. For operation it requires a BU type U0 BaseUnit (2-wire connection), ordered separately. Verify the BaseUnit is on hand before the slot is assigned — no holes in the box. Mechanical footprint: 58 mm depth x 20 mm width x 73 mm height, fitting any mounting position. Wiring to the BaseUnit supports shielded or unshielded cable runs up to 200 m, terminated through the spring-cage connectors on the BU type U0. ## Lifecycle & sourcing posture This is the module to specify for new builds or spares, with firmware V8.0 as the current revision. Sourced to order; RFQ for lead time and availability. Diagnostic alarm, limit value alarm, and hardware interrupt with monitoring of up to 16 freely selectable process values give real-time fault visibility. The module supports isochronous mode? No — isochronous mode is not supported, so it is not suited for cycle-synchronous applications demanding T1 deterministic updates. Rated supply 24 V DC, drawn from the backplane bus via the BaseUnit. Typical power loss is 400 mW, leaving margin for dense modules on the same segment. Overvoltage category CAT II per IEC 61010-1, with a maximum secondary-side voltage of 300 V. Input resistance 120 kΩ per channel.","metaTitle":"Siemens 6ES7134-6PA21-0BU0 ET 200SP AI Energy, 58 mm","metaDescription":"Active-production Siemens ET 200SP analog input module for power/energy measurement. 256-byte inputs, 24 V DC, 58 mm depth. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Analog Input Modules"],"specifications":{"Depth":"58 mm","Width":"20 mm","title":"6ES7134-6PA21-0BU0","Height":"73 mm","Inputs":"256 byte","Outputs":"20 byte","Present":"Yes","I&M data":"Yes; I&M0 to I&M3","description":"SIMATIC ET 200SP, analog input module, AI Energy Meter RC ST, for Rogowski coils or current/voltage transformer 333 mV, suitable for BU type U0, channel diagnostics","Module fault":"Yes","Line analysis":"No","Shielded, Max.":"200 m","Supply voltage":"Yes","Weight, approx.":"45 g","lifecycle_stage":"current","Diagnostic alarm":"Yes","Firmware version":"V8.0","Input resistance":"120 kΩ","Isochronous mode":"No","Overload current":"Yes","Parameter length":"128 byte","Power loss, typ.":"400 mW; 3x 230 V AC","Rated value (DC)":"24 V","Unshielded, Max.":"200 m","usable BaseUnits":"BU type U0","2-Wire Connection":"BU type U0","Limit value alarm":"Yes","Mounting position":"any","Power measurement":"Yes","Automatic encoding":"Yes","Energy measurement":"Yes","FW update possible":"Yes","Hardware interrupt":"Yes; Monitoring of up to 16 freely selectable process values (exceeding or undershooting of value)","Overflow/underflow":"Yes","With Rogowski coil":"Yes","Current measurement":"Yes; max. 3 + neutral conductor","Voltage measurement":"Yes","Between The Channels":"No","Overvoltage category":"CAT II according to IEC 61010 Part 1","Secondary side, max.":"300 V","Channel not available":"Yes","Frequency measurement":"Yes","Isolation tested with":"Between channels and backplane bus, 24 V supply: Routine test, 1 920 V AC, 2 s; between backplane bus and 24 V supply: Type test, 707 V DC","Channel status display":"Yes; green LED","Curve shape of voltage":"Sinusoidal or distorted","For Module Diagnostics":"Yes; green/red DIAG LED","Zero point suppression":"Yes; 0 ... 20%, referred to the nominal current","For Channel Diagnostics":"Yes; red Fn LED","Hardware interrupt lost":"Yes","Active power measurement":"Yes","Power factor measurement":"Yes","Sampling frequency, max.":"2 048 kHz","With Current Transformer":"No","With Voltage Transformer":"Yes","Active factor measurement":"Yes","Current consumption, max.":"17 mA","Fixed measured value sets":"Yes","Measured variable current":"0,2","Measured variable voltage":"0,2","Mechanical coding element":"Yes","Parameter assignment error":"Yes","Reactive power measurement":"Yes","Calibration possible in RUN":"Yes","Frequency measurement, max.":"70 Hz","Frequency measurement, min.":"40 Hz","Measured variable frequency":"0.05; only valid for the permissible voltage measuring range","Power consumption per phase":"60 mW; 300 V AC","Reactive power compensation":"Yes","Vertical Installation, Max.":"50 °C","Vertical Installation, Min.":"-30 °C","Without Current Transformer":"No","Without Voltage Transformer":"Yes","Cyclic measured value access":"Yes","Acyclic measured value access":"Yes","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"-30 °C","Measured variable phase angle":"±0.5 °; not covered by IEC 61557-12","Measurable current at AC, max.":"424 mV","Measured variable active power":"0.5","Measured variable power factor":"0.5","Supported power supply systems":"TT, TN, IT","With current-voltage-converter":"Yes; 333 mV interface","Buffering of measured variables":"Yes","Cycle time (all channels), typ.":"50 ms; Time for consistent update of all measured and calculated values (cyclic und acyclic data)","Measured variable active energy":"0.5","Measured variable apparent power":"0.5","Measured variable reactive power":"1","Current consumption (rated value)":"12.5 mA","Measured variable neutral current":"0,2","Measured variable reactive energy":"1","Type of mechanical coding element":"type C","Reparameterization possible in RUN":"Yes","Type of measured value acquisition":"seamless","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Freely definable measured value sets":"Yes; For cyclic and acyclic measured value access","Impulse voltage resistance 1,2/50μs":"2.5 kV","Between The Channels And Backplane Bus":"Yes","PROFIBUS from GSD version/GSD revision":"One GSD file each, Revision 3 and 5 and higher","PROFINET from GSD version/GSD revision":"V2.3","Bandwidth of measured value acquisition":"3.2 kHz; Harmonics: 63 / 50 Hz, 52 / 60 Hz","Continuous voltage, maximum permissible":"2 V","Between the channels and load voltage L+":"Yes; Including FE","Switching between operating modes in RUN":"Yes; For module version 32 I/20 Q, it is possible to dynamically switch between 25 user data variants, 23 of which are pre-defined and 2 of which can be defined by the specific user","Monitoring of the supply voltage (PWR-LED)":"Yes","Installation altitude above sea level, max.":"3 000 m; Restrictions for installation altitudes > 2 000 m, see manual","Measuring procedure for current measurement":"TRMS","Measuring procedure for voltage measurement":"TRMS","STEP 7 configurable/integrated from version":"Configurable via GSD file","Measurable line voltage between the line conductors":"480 V","STEP 7 TIA Portal configurable/integrated from version":"STEP 7 V16 or higher with HSP","Internal resistance line conductor and neutral conductor":"1.5 MΩ","Color code for module-specific color identification plate":"CC20","Measurable line voltage between the line conductors, max.":"519 V","Measurable line voltage between the line conductors, min.":"6 V","Measurable line voltage between phase and neutral conductor":"277 V","Rated value, short-time withstand voltage restricted to 1 s":"30 V","Measurable line voltage between phase and neutral conductor, max.":"300 V","Measurable line voltage between phase and neutral conductor, min.":"3 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$144.78","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e5444c2a6d45e12e1a825e1259ff12c7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1440332&mlfb=6ES7134-6PA21-0BU0"},"ai":{"faq":[{"question":"What are the module dimensions?","answer":"Depth 58 mm, width 20 mm, height 73 mm. The 20 mm width occupies one slot on the ET 200SP rail."},{"question":"Can the module be used in isochronous mode?","answer":"No. Isochronous mode is not supported. This module is not intended for applications requiring synchronized cycle updates."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7134-6PA21-0BU0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7134-6PA21-0BU0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}