{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7134-6PA21-0CU0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7134-6PA21-0CU0","canonicalUrl":"https://aoctrl.com/siemens/6ES7134-6PA21-0CU0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7134-6PA21-0CU0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC ET 200SP analog input / energy measurement module, 6ES7134-6PA21-0CU0, 24 V DC supply, 58×20×73 mm, firmware V8.0.","salesMarkdown":"## Integrator Field Note The 6ES7134-6PA21-0CU0 is an ET 200SP energy measurement module that sits on a BU type U0 base unit. It measures current (up to 4 channels) and voltage, calculates power and energy, and flags limit-value alarms or hardware interrupts on up to 16 selectable process values. Supply is 24 V DC from the backplane; no external power needed. Firmware is V8.0 out of the box, and the module supports I&M data (I&M0–I&M3) plus online firmware update. ## Mechanical Fit & Integration Width 20 mm, depth 58 mm, height 73 mm — occupies a single ET 200SP slot. It requires a BU type U0 base unit (order separately). Shielded or unshielded cable runs up to 200 m per channel. Input resistance is 120 kΩ; power loss typ. 400 mW at 230 V AC. ## Diagnostics & Commissioning Standard diagnostics include line quality analysis, voltage swell/dip detection, overflow/underflow, and overload current monitoring. A diagnostic alarm or hardware interrupt can be assigned to any of 16 process thresholds. Automatic encoding means the module self-identifies on the backplane — no DIP-switch mapping. For FAT/SAT, the parameter length is 128 bytes and the I&M data helps track module history.","metaTitle":"Siemens 6ES7134-6PA21-0CU0 ET 200SP Module, 24 V DC, 20 mm","metaDescription":"Current lifecycle ET 200SP analog input/energy module. 58 mm depth, 20 mm width, firmware V8.0. Diagnostic alarms and I&M data supported. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Analog Input Modules"],"specifications":{"Depth":"58 mm","Width":"20 mm","title":"6ES7134-6PA21-0CU0","Height":"73 mm","Inputs":"256 byte","Outputs":"20 byte","Present":"Yes","I&M data":"Yes; I&M0 to I&M3","description":"SIMATIC ET 200SP, analog input module, AI Energy Meter RC HF, for Rogowski coils or current/voltage transformer 333 mV, with network analysis functions, suitable for BU type U0, channel diagnostics","Line quality":"Yes","Module fault":"Yes","Line analysis":"Yes","Voltage swell":"Yes","Shielded, Max.":"200 m","Supply voltage":"Yes","Weight, approx.":"45 g","lifecycle_stage":"current","Diagnostic alarm":"Yes","Firmware version":"V8.0","Input resistance":"120 kΩ","Isochronous mode":"No","Overload current":"Yes","Parameter length":"128 byte","Power loss, typ.":"400 mW; 3x 230 V AC","Rated value (DC)":"24 V","Unshielded, Max.":"200 m","usable BaseUnits":"BU type U0","2-Wire Connection":"BU type U0","Limit value alarm":"Yes","Mounting position":"any","Power measurement":"Yes","Voltage dip (DIP)":"Yes","Automatic encoding":"Yes","Energy measurement":"Yes","FW update possible":"Yes","Hardware interrupt":"Yes; Monitoring of up to 16 freely selectable process values (exceeding or undershooting of value)","Overflow/underflow":"Yes","With Rogowski coil":"Yes","Current measurement":"Yes; Max. 4","Voltage measurement":"Yes","Between The Channels":"No","Overvoltage category":"CAT II according to IEC 61010 Part 1","Secondary side, max.":"300 V","Channel not available":"Yes","Frequency measurement":"Yes","Isolation tested with":"Between channels and backplane bus, 24 V supply: Routine test, 1 920 V AC, 2 s; between backplane bus and 24 V supply: Type test, 707 V DC","Channel status display":"Yes; green LED","Curve shape of voltage":"Sinusoidal or distorted","For Module Diagnostics":"Yes; green/red DIAG LED","Measured variable THDI":"1","Measured variable THDU":"1","Zero point suppression":"Yes; 0 ... 20%, referred to the nominal current","For Channel Diagnostics":"Yes; red Fn LED","Hardware interrupt lost":"Yes","Active power measurement":"Yes","Power factor measurement":"Yes","Sampling frequency, max.":"2 048 kHz","With Current Transformer":"No","With Voltage Transformer":"Yes","Active factor measurement":"Yes","Current consumption, max.":"17 mA","Fixed measured value sets":"Yes","Measured variable current":"Class S","Measured variable voltage":"Class S","Mechanical coding element":"Yes","Measured variable harmonic":"1","Parameter assignment error":"Yes","Reactive power measurement":"Yes","Calibration possible in RUN":"Yes","Frequency measurement, max.":"70 Hz","Frequency measurement, min.":"40 Hz","Measured variable frequency":"Class S","Power consumption per phase":"60 mW; 300 V AC","Reactive power compensation":"Yes","Vertical Installation, Max.":"50 °C","Vertical Installation, Min.":"-30 °C","Without Current Transformer":"No","Without Voltage Transformer":"Yes","Cyclic measured value access":"Yes","Acyclic measured value access":"Yes","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"-30 °C","Measured variable phase angle":"±0.5 °; not covered by IEC 61557-12","Measurable current at AC, max.":"424 mV","Measured variable active power":"0.5","Measured variable power factor":"0.5","Supported power supply systems":"TT, TN, IT","With current-voltage-converter":"Yes; 333 mV interface","Buffering of measured variables":"Yes","Cycle time (all channels), typ.":"50 ms; Time for consistent update of all measured and calculated values (cyclic und acyclic data)","Measured variable active energy":"0.5","Measured variable apparent power":"0.5","Measured variable reactive power":"1","Current consumption (rated value)":"12.5 mA","Harmonics for current and voltage":"Yes","Measured variable neutral current":"0,2","Measured variable reactive energy":"1","Type of mechanical coding element":"type C","Measured variable harmonic current":"Class S","Measured variable harmonic voltage":"Class S","Reparameterization possible in RUN":"Yes","Type of measured value acquisition":"seamless","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Freely definable measured value sets":"Yes; For cyclic and acyclic measured value access","Impulse voltage resistance 1,2/50μs":"2.5 kV","Between The Channels And Backplane Bus":"Yes","Measured variable voltage interruption":"Class S","PROFIBUS from GSD version/GSD revision":"One GSD file each, Revision 3 and 5 and higher","PROFINET from GSD version/GSD revision":"V2.3","Bandwidth of measured value acquisition":"3.2 kHz; Harmonics: 63 / 50 Hz, 52 / 60 Hz","Continuous voltage, maximum permissible":"2 V","Measured variable voltage dip and swell":"Class S","THD measurement for current and voltage":"Yes","Between the channels and load voltage L+":"Yes; Including FE","Switching between operating modes in RUN":"Yes; For module version 32 I/20 Q, it is possible to dynamically switch between 25 user data variants, 23 of which are pre-defined and 2 of which can be defined by the specific user","Monitoring of the supply voltage (PWR-LED)":"Yes","Installation altitude above sea level, max.":"3 000 m; Restrictions for installation altitudes > 2 000 m, see manual","Measuring procedure for current measurement":"TRMS","Measuring procedure for voltage measurement":"TRMS","STEP 7 configurable/integrated from version":"V5.5 SP3 or higher","Monitoring of instantaneous and half-wave values":"Yes","Measurable line voltage between the line conductors":"480 V","STEP 7 TIA Portal configurable/integrated from version":"STEP 7 V16 or higher with HSP","Internal resistance line conductor and neutral conductor":"1.5 MΩ","Color code for module-specific color identification plate":"CC20","Measurable line voltage between the line conductors, max.":"519 V","Measurable line voltage between the line conductors, min.":"6 V","Measurable line voltage between phase and neutral conductor":"277 V","Rated value, short-time withstand voltage restricted to 1 s":"30 V","Measurable line voltage between phase and neutral conductor, max.":"300 V","Measurable line voltage between phase and neutral conductor, min.":"3 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e5444c2a6d45e12e1a825e1259ff12c7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1440333&mlfb=6ES7134-6PA21-0CU0"},"ai":{"faq":[{"question":"What are the key dimensions of this module?","answer":"Width 20 mm, depth 58 mm, height 73 mm. It fits a standard ET 200SP slot with BU type U0 base unit."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7134-6PA21-0CU0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7134-6PA21-0CU0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}