{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7135-4LB02-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7135-4LB02-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7135-4LB02-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7135-4LB02-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens ET 200S, analog output module, 2 analog outputs voltage, 15 mm wide, active production.","salesMarkdown":"## Integration into an ET 200S station The 6ES7135-4LB02-0AB0: Width is 15 mm, depth 52 mm, height 81 mm — fits one slot in any ET 200S interface module. The module draws max. 10 mA from the backplane bus and max. 80 mA from load voltage L+. Reverse polarity protection on L+ is built in. Analog outputs are voltage only. For a two-wire or four-wire voltage connection, the module supplies a max. 25 mA short-circuit current with short-circuit protection. Minimum load resistance for a voltage output is 1 kΩ. Cycle time (all channels) is 0.5 ms at max. 0.5 µF load capacitance. This is the settling time for the D/A conversion — not the PROFIBUS cycle. For applications requiring deterministic timing, the module supports isochronous mode. ## Diagnostics and setpoints Group diagnostics, short-circuit diagnostics, and diagnostic interrupt are configurable (disable/enable per channel). The module reports a group error (SF LED) and individual channel diagnostics via the backplane bus. Diagnostic information is readable. On CPU/master STOP, the outputs can be set to output current and de-energized, substitute a value, or keep last value — configurable in the hardware configuration. This is standard for ET 200S analog modules; verify the setting matches the safety logic of the plant. Address space per module is 4 bytes (2 channels, 2 bytes each). Remark field shows 7 bytes — but the address space per module is listed as 4 bytes. This discrepancy likely includes the diagnostic and configuration bytes; for the analog value itself, expect 2 words per channel.","metaTitle":"Siemens 6ES7135-4LB02-0AB0 ET 200S Analog Output Module, 2AO","metaDescription":"Active production Siemens 6ES7135-4LB02-0AB0 analog output module for ET 200S. Two channels, voltage ranges including -10V to +10V, isochronous mode. 15 mm wide. Sourced to order p","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLC I/O & Expansion Modules"],"specifications":{"Depth":"52 mm","Width":"15 mm","title":"6ES7135-4LB02-0AB0","Height":"81 mm","Remark":"7 byte","1 V to 5 V":"Yes","Group error":"Yes","description":"SIMATIC DP, Electronics module 2 AO U High Feature for ET 200S, 15 mm width, Cycle time per module: 0.5 ms, +/-10V; 15 bit+sign, 1.. 5V; 15 bit, Operational limit +/-0.07% with SF LED (group fault)","-5 V to +5 V":"Yes","Short-circuit":"Yes","-10 V to +10 V":"Yes","Shielded, Max.":"200 m; 100 m if Twa < 2 ms","Weight, approx.":"40 g","lifecycle_stage":"current","Isochronous mode":"Yes","Power loss, max.":"1.2 W","Rated value (DC)":"24 V","Group diagnostics":"Disable / enable","For Inductive Load":"0.5 ms","For Resistive Load":"0.2 ms","For Capacitive Load":"0.5 ms; At max. 0.5 µF","Between The Channels":"No","Group error SF (red)":"Yes","Isolation tested with":"500 V DC","Number of analog outputs":"2","Diagnostics short-circuit":"Disable / enable","With Voltage Outputs, Min.":"1 kΩ","Response to CPU/master STOP":"Output current and de-energized/substitute a value/keep last value","Reverse polarity protection":"Yes","Address space per module, max.":"4 byte","Cycle time (all channels) max.":"0.5 ms; At max. 0.5 µF","Diagnostic information readable":"Yes","from backplane bus 3.3 V DC, max.":"10 mA","Voltages at the outputs towards MANA":"15 V; max. 15 V continuous; 75 V for max. 1 s (mark to space ratio 1:20)","Between The Channels And Backplane Bus":"Yes","For Voltage Output Two-Wire Connection":"Yes","For Voltage Output Four-Wire Connection":"Yes","Between the channels and load voltage L+":"Yes","Voltage output, short-circuit protection":"Yes","Voltage, relative to output range, (+/-)":"0.05 %","from load voltage L+ (without load), max.":"80 mA","Voltage output, short-circuit current, max.":"25 mA","With Voltage Outputs, Capacitive Load, Max.":"0.5 µF","Resolution with overrange (bit including sign), max.":"16 bit; 15 bit + sign"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$280.00 – $304.80","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e5444c2a6d45e12e1a825e1259ff12c7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=111072&mlfb=6ES7135-4LB02-0AB0"},"ai":{"faq":[{"question":"How do I source this part?","answer":"This is an active, current-production Siemens module. Submit an RFQ with your target quantity and desired lead time. We will quote against available stock and factory lead time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7135-4LB02-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7135-4LB02-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}