{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7135-6HB00-0CA1","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7135-6HB00-0CA1","canonicalUrl":"https://aoctrl.com/siemens/6ES7135-6HB00-0CA1","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7135-6HB00-0CA1","rawCanonicalId":null},"summary":{"shortDescription":"Siemens ET 200SP, 6ES7135-6HB00-0CA1, 2-channel analog output module, 15 mm width, 16-bit resolution voltage/current, BU type A0/A1, current production.","salesMarkdown":"## 2-channel analog output — 15 mm slice for ET 200SP The Siemens 6ES7135-6HB00-0CA1 is a 2-channel analog output module for the ET 200SP distributed I/O system. It fits a 15 mm wide BaseUnit (BU type A0 or A1) and draws a maximum of 90 mA from the 24 V DC backplane bus. Resolution tops at 16 bits including sign for the ±10 V and ±20 mA ranges — enough for precision valve or drive setpoint loops. The 5 µs jitter ceiling keeps the output update deterministic for isochronous motion control. ## Voltage and current ranges — what the bits buy you The module covers seven output ranges: 0–10 V (15 bit), 0–20 mA (15 bit), 4–20 mA (14 bit), 1–5 V (13 bit), ±5 V (15 bit incl. sign), ±10 V (16 bit incl. sign), and ±20 mA (16 bit incl. sign). The voltage output cable is limited to 200 m shielded; current outputs can run 1 000 m shielded. Load settling is 0.05 ms for resistive, inductive, or capacitive loads (max 47 nF at 20 m cable). That 0.05 ms is the same across all three load types — the module does not slow down for inductive or capacitive loops. Wire-break detection works per channel, but only when the output type is set to current. Short-circuit detection is per channel, only for voltage output type. Both diagnostics trigger a group error and a diagnostic alarm. ## Lifecycle and sourcing — active, no LTB pressure Hardware functional status starts at FS04. The module carries I&M data (I&M0 to I&M3) for asset tracking. Isolation is tested at 707 V DC type test between the bus and the field circuits. ## Panel fit and field wiring Compatible BaseUnits are BU type A0 and A1. The module does not support oversampling or MSO (multi-step operation). Channel-to-channel isolation is not provided — the outputs share a common reference. Three status LEDs: green for channel status, green/red DIAG for module diagnostics, and red for channel diagnostics. Power loss is 0.9 W typical.","metaTitle":"Siemens 6ES7135-6HB00-0CA1 ET 200SP Analog Output Module","metaDescription":"Siemens 6ES7135-6HB00-0CA1 ET 200SP analog output module, 2 channels, 16-bit resolution, supports -10 to +10 V, 0-20 mA, wire-break detection, BU type A0/A1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Analog Output Modules"],"specifications":{"MSO":"No","Depth":"58 mm","Width":"15 mm","title":"6ES7135-6HB00-0CA1","Height":"73 mm","I&M data":"Yes; I&M0 to I&M3","0 to 10 V":"Yes; 15 bit","0 to 20 mA":"Yes; 15 bit","1 V to 5 V":"Yes; 13 bit","Wire-break":"Yes; channel-by-channel, only for output type \"current\"","Group error":"Yes","description":"SIMATIC ET 200SP, Analog output module, AQ 2x U/I High Feature suitable for BU type A0, A1, Color code CC00, channel diagnostics, 16 bit, +/-0.1%","-5 V to +5 V":"Yes; 15 bit incl. sign","Jitter, max.":"5 µs","Oversampling":"No","4 mA to 20 mA":"Yes; 14 bit","Short-circuit":"Yes; channel-by-channel, only for output type \"voltage\"","-10 V to +10 V":"Yes; 16 bit incl. sign","Shielded, Max.":"1 000 m; 200 m for voltage output","Weight, approx.":"31 g","lifecycle_stage":"current","-20 mA to +20 mA":"Yes; 16 bit incl. sign","Diagnostic alarm":"Yes","Isochronous mode":"Yes","Power loss, typ.":"0.9 W","Rated value (DC)":"24 V","usable BaseUnits":"BU type A0, A1","For Inductive Load":"0.05 ms","For Resistive Load":"0.05 ms","Overflow/underflow":"Yes","For Capacitive Load":"0.05 ms; Max. 47 nF and 20 m cable length","Between The Channels":"No","Diagnostics function":"Yes","HW functional status":"from FS04","Isolation tested with":"707 V DC (type test)","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; green/red DIAG LED","For Channel Diagnostics":"Yes; red LED","Voltages at the outputs":"30 V","Number of analog outputs":"2","Current consumption, max.":"90 mA; 2 channels current output 20 mA","Mechanical coding element":"Yes","Bus cycle time (TDP), min.":"750 µs","With Current Outputs, Max.":"500 Ω","With Voltage Outputs, Min.":"2 kΩ","Calibration possible in RUN":"Yes","Reverse polarity protection":"Yes","Vertical Installation, Max.":"50 °C","Vertical Installation, Min.":"-30 °C; < 0 °C as of FS04","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"-30 °C; < 0 °C as of FS04","Monitoring the supply voltage":"Yes","Substitute values connectable":"Yes","Address space per module, max.":"4 byte; + 1 byte for QI information","Cycle time (all channels), min.":"750 µs","Current consumption (rated value)":"45 mA; without load","Type of mechanical coding element":"Type A","Reparameterization possible in RUN":"Yes","Crosstalk between the outputs, max.":"-50 dB","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Between The Channels And Backplane Bus":"Yes","For Current Output Two-Wire Connection":"Yes","For Voltage Output Two-Wire Connection":"Yes","PROFIBUS from GSD version/GSD revision":"GSD Revision 5","PROFINET from GSD version/GSD revision":"GSDML V2.3","For Voltage Output Four-Wire Connection":"Yes","Current, relative to output range, (+/-)":"0.1 %","Voltage output, short-circuit protection":"Yes","Voltage, relative to output range, (+/-)":"0.1 %","Execution and activation time (TCO), min.":"500 µs","Monitoring of the supply voltage (PWR-LED)":"Yes; green PWR LED","PCS 7 configurable/integrated from version":"V8.1 SP1","With Current Outputs, Inductive Load, Max.":"1 mH","Installation altitude above sea level, max.":"5 000 m; Restrictions for installation altitudes > 2 000 m, see manual","STEP 7 configurable/integrated from version":"V5.5 SP3 / -","Voltage output, short-circuit current, max.":"45 mA","With Voltage Outputs, Capacitive Load, Max.":"1 µF","Linearity error (relative to output range), (+/-)":"0.03 %","Temperature error (relative to output range), (+/-)":"0.003 %/K","Resolution with overrange (bit including sign), max.":"16 bit","STEP 7 TIA Portal configurable/integrated from version":"V13 / V13","Color code for module-specific color identification plate":"CC00","Between The Channels And The Power Supply Of The Electronics":"Yes","Output ripple (relative to output range, bandwidth 0 to 50 kHz), (+/-)":"0.02 %","Repeat accuracy in steady state at 25 °C (relative to output range), (+/-)":"0.03 %"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$156.21","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/356df2c7c0e91e7f33e7b83c331c1654.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=12586&mlfb=6ES7135-6HB00-0CA1"},"ai":{"faq":[{"question":"Is 6ES7135-6HB00-0CA1 compatible with base unit type A0?","answer":"Yes, it works with BU type A0 and also with BU type A1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7135-6HB00-0CA1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7135-6HB00-0CA1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}