{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7135-7TD00-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7135-7TD00-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7135-7TD00-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7135-7TD00-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC DP ET200iSP electronic module, 6ES7135-7TD00-0AB0, 4 analog outputs HART, 4-20 mA, Ex ib (ia Ga) IIC T4 Gb, Ex ib [ia IIIC Da] IIC T4 Gb, Ex ib [ia] I Mb.","salesMarkdown":"## 4 AO HART for ET200iSP in hazardous areas The Siemens 6ES7135-7TD00-0AB0 is a SIMATIC DP electronic module for the ET200iSP distributed I/O system, providing 4 analog outputs with HART protocol support for connecting HART field devices in hazardous-area installations. It carries Ex ib (ia Ga) IIC T4 Gb, Ex ib [ia IIIC Da] IIC T4 Gb, and Ex ib [ia] I Mb approvals. ## Output performance and loop drive Each of the 4 channels outputs 4 mA to 20 mA (also supports 0 to 20 mA) into a maximum load of 750 Ω with current outputs — enough to drive a typical HART transmitter or I/P positioner plus cable resistance in a long loop. Resolution is 14 bit including sign, with a linearity error of ±0.015 % and a repeat accuracy of ±0.01 % at 25 °C, so the loop stays tight for custody-transfer or critical process control. Crosstalk between outputs is better than -50 dB, which means a step change on one channel won't couple into an adjacent loop and upset a sensitive control valve. The module detects wire-break and short-circuit conditions on each output, and reports diagnostic alarms via the backplane bus — the SF (red) group error LED gives the panel operator a visual cue before the process drifts. ## Panel fit and power budget The module measures 30 mm wide × 129 mm high × 136.5 mm deep, fitting a standard ET200iSP slot in the hazardous-area I/O cabinet. Typical power loss is 2.7 W, and it draws 295 mA from the backplane bus — well within the power budget of an ET200iSP interface module. Maximum cycle time across all 4 channels is 3.6 ms, fast enough for most process control loops; the module supports substitute values if communication to the DP master is lost, so the last good output value holds the process steady.","metaTitle":"Siemens 6ES7135-7TD00-0AB0 ET200iSP 4 AO HART, 4-20mA","metaDescription":"Siemens 6ES7135-7TD00-0AB0 SIMATIC DP electronic module for ET200iSP, 4 analog outputs HART, 4-20mA, Ex ib (ia Ga) IIC T4 Gb.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLC I/O & Expansion Modules"],"specifications":{"Depth":"136.5 mm","Width":"30 mm","Height":"129 mm","CE mark":"Yes","0 to 20 mA":"Yes","Wire-break":"Yes","4 mA to 20 mA":"Yes","Short-circuit":"Yes","Shielded, Max.":"500 m","Weight, approx.":"265 g","lifecycle_stage":"current","Diagnostic alarm":"Yes","Power loss, typ.":"2.7 W","For Inductive Load":"40 ms","For Resistive Load":"4 ms","For Capacitive Load":"40 ms","Between The Channels":"No","Group error SF (red)":"Yes","Number of analog outputs":"4","Current consumption, typ.":"295 mA","With Current Outputs, Max.":"750 Ω","Substitute values connectable":"Yes","Cycle time (all channels) max.":"3.6 ms","Diagnostic information readable":"Yes","Crosstalk between the outputs, min.":"-50 dB","Between The Channels And Backplane Bus":"Yes","For Current Output Two-Wire Connection":"Yes","Current, relative to output range, (+/-)":"0.1 %","from load voltage L+ (without load), max.":"330 mA","Linearity error (relative to output range), (+/-)":"0.015 %","Temperature error (relative to output range), (+/-)":"0.005 %/K","Resolution with overrange (bit including sign), max.":"14 bit","Repeat accuracy in steady state at 25 °C (relative to output range), (+/-)":"0.01 %"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$416.56 – $853.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e5444c2a6d45e12e1a825e1259ff12c7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=408550&mlfb=6ES7135-7TD00-0AB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7135-7TD00-0AB0/alternatives.json"},"ai":{"faq":[{"question":"Is 6ES7135-7TD00-0AB0 compatible with ET200iSP?","answer":"Yes, the 6ES7135-7TD00-0AB0 is a SIMATIC DP electronic module designed specifically for the ET200iSP distributed I/O system, with Ex approvals for hazardous-area installation."},{"question":"Does 6ES7135-7TD00-0AB0 support HART protocol?","answer":"Yes, it supports HART protocol version 6.0 for connecting HART field devices, enabling digital communication overlay on the 4-20 mA analog signal for configuration and diagnostics."},{"question":"What is the power consumption of 6ES7135-7TD00-0AB0?","answer":"Typical power loss is 2.7 W, and it draws 295 mA from the backplane bus (330 mA maximum from load voltage L+ without load)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7135-7TD00-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7135-7TD00-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}