{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7136-6AB00-0CA1","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7136-6AB00-0CA1","canonicalUrl":"https://aoctrl.com/siemens/6ES7136-6AB00-0CA1","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7136-6AB00-0CA1","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC ET 200SP analog input module, 6ES7136-6AB00-0CA1, Sigma-Delta, 0 to +10 V, 24 V supply, SIL 3, 15 mm width, current production.","salesMarkdown":"## What the module is and where it drops in The Siemens 6ES7136-6AB00-0CA1 is a SIMATIC ET 200SP analog input module on the ET 200SP distributed I/O platform, designed to land on a BU type A0 or A1 BaseUnit and serve safety-related signal acquisition when paired with an S7-300/400F CPU. Lifecycle stage is current. ## What the headline ratings actually buy you The analog input range covers 0 to +10 V, with cyclic measurement and an average value filter available, while MSI (simultaneous mode) is not supported on this variant. Encoder and channel supply is rated up to 300 mA total current of all encoders / channels — the package ceiling, not a per-pin figure. Typical power dissipation is 2 W, fed from a 24 V supply on L+ with the module tolerating a minimum of L+ minus 1.5 V. Galvanic isolation is type-tested at 707 V DC. Shielded field wiring is permitted up to 200 m between the field device and the BaseUnit, which is the practical ceiling for laying this module out on a plant floor. ## Diagnostics and channel indication Channel-level diagnostics include a red ERROR LED per channel, a green channel-status LED, and wire-break detection at the analog front end, so an open sensor leads on the field shows up at the module face and as a diagnostic alarm in the CPU. Module-level diagnostics ride on a green/red DIAG LED, with I&M0 through I&M3 identification data and firmware-update capability supported. The module is parameterizable and supports automatic encoding on the BaseUnit; oversampling is not present on this variant. A limit-value alarm per channel is not provided; alarm behavior here is the diagnostic alarm, not a high/low threshold. ## Footprint, BaseUnit pairing, and panel-side notes Process-image footprint is 14 bytes of inputs and 5 bytes of outputs as a standard module, dropping to 13 bytes of inputs and 4 bytes of outputs when addressed by an S7-300/400F CPU, which is the layout to reserve in the I/O map.","metaTitle":"Siemens 6ES7136-6AB00-0CA1, AI 4xU/I, SIL 3","metaDescription":"Siemens 6ES7136-6AB00-0CA1 ET 200SP analog input module, 0–10 V, SIL 3, Sigma-Delta, 24 V. Current production. Specs and sourcing.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLC I/O & Expansion Modules"],"specifications":{"MSI":"No","24 V":"Yes; min. L+ (-1.5 V)","Depth":"58 mm","Width":"15 mm","title":"6ES7136-6AB00-0CA1","Height":"73 mm","Inputs":"14 byte; S7-300/400F CPU, 13 byte","Outputs":"5 byte; S7-300/400F CPU, 4 byte","RUN LED":"Yes; green LED","I&M data":"Yes; I&M0 to I&M3","ERROR LED":"Yes; red LED","Step: low":"Yes; 2x / 4x conversion cycle time","0 to +10 V":"Yes","Step: High":"Yes; 32x / 64x conversion cycle time","Step: None":"Yes; 1x conversion cycle time","Wire-break":"Yes","description":"SIMATIC DP, electronics module ET 200SP, F-AI 4xU 0..10V HF, fail-safe analog inputs, up to PL E (ISO 13849), up to SIL 3 (IEC 61508)","Oversampling":"No","Step: Medium":"Yes; 8x / 16x conversion cycle time","Shielded, Max.":"200 m","Parameterizable":"Yes","Weight, approx.":"48 g","lifecycle_stage":"current","Diagnostic alarm":"Yes","Power loss, typ.":"2 W","Rated value (DC)":"24 V","usable BaseUnits":"BU type A0, A1","Limit value alarm":"No","Automatic encoding":"Yes","Cyclic Measurement":"Yes","FW update possible":"Yes","Average value filter":"Yes","Between The Channels":"No","Diagnostics function":"Yes","Output current, max.":"300 mA; total current of all encoders/channels","Integration time (ms)":"20 / 16,667","Isolation tested with":"707 V DC (type test)","Measurement principle":"Sigma Delta","SIL acc. to IEC 61508":"SIL 3","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; green/red DIAG LED","For Channel Diagnostics":"Yes; red LED","For Voltage Measurement":"Yes","For voltage measurement":"4","Number of analog inputs":"4","Short-circuit protection":"Yes","between the inputs (UCM)":"10 Vpp","Common mode voltage, max.":"10 V","Current consumption, max.":"0.4 A","Number of smoothing levels":"7","Calibration possible in RUN":"No","Reverse polarity protection":"Yes","Vertical Installation, Max.":"50 °C","Vertical Installation, Min.":"0 °C","Input resistance (0 to 10 V)":"16 kΩ","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"0 °C","Monitoring the supply voltage":"Yes","Common mode interference, min.":"70 dB","Electronic coding element type H":"Yes","Category according to ISO 13849-1":"Cat. 4","Current consumption (rated value)":"0.38 A","Integration time, parameterizable":"Yes","Reparameterization possible in RUN":"No","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Between The Channels And Backplane Bus":"Yes","Power available from the backplane bus":"70 mW","Voltage, relative to input range, (+/-)":"0.1 %","Monitoring of the supply voltage (PWR-LED)":"Yes; green PWR LED","Performance level according to ISO 13849-1":"PLe","power supply according to NEC Class 2 required":"No","Low demand mode: PFDavg in accordance with SIL3":"< 5.00E-05","Linearity error (relative to input range), (+/-)":"0.1 %","Temperature error (relative to input range), (+/-)":"0.023 %/K","Resolution with overrange (bit including sign), max.":"16 bit","STEP 7 TIA Portal configurable/integrated from version":"V16 with HSP 308","High demand/continuous mode: PFH in accordance with SIL3":"< 1.00E-09 1/h","Color code for module-specific color identification plate":"CC00","Between The Channels And The Power Supply Of The Electronics":"Yes","Interference voltage suppression for interference frequency f1 in Hz":"50 / 60 Hz","Permissible Input Voltage For Voltage Input (Destruction Limit), Max.":"36 V","Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)":"0.1 %","Series mode interference (peak value of interference < rated value of input range), min.":"40 dB"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$365.76 – $1,074.61","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3903b92f21e42c6e0cd4a89972e66550.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1418567&mlfb=6ES7136-6AB00-0CA1"},"ai":{"faq":[{"question":"What is the listed MSI capability on 6ES7136-6AB00-0CA1?","answer":"MSI is No on this variant — it is not a simultaneous-input module."},{"question":"What is the listed 24 V supply rating on 6ES7136-6AB00-0CA1?","answer":"The module accepts 24 V on L+, with a minimum allowed rail of L+ minus 1.5 V."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7136-6AB00-0CA1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7136-6AB00-0CA1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}