{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7143-5BF00-0BL0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7143-5BF00-0BL0","canonicalUrl":"https://aoctrl.com/siemens/6ES7143-5BF00-0BL0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7143-5BF00-0BL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC ET 200SP IO-Link module 6ES7143-5BF00-0BL0, 8 outputs, 24 V DC, 0.7 A total, IP65/67, -30 to 55 °C, SIL 2.","salesMarkdown":"## IO-Link module for ET 200SP The 6ES7143-5BF00-0BL0: Current-production IO-Link module for the SIMATIC ET 200SP distributed I/O system. Supplies 8 digital outputs at 24 V DC, total current 0.7 A sourced from the IO-Link master's 2UA+ rail. Rated IP65/67 and SIL 2. Usable on machine frames and in protected zones. Temperature range –30 to 55 °C matches most production environments; no additional cooling needed at the upper end unless you're overloading the total output current. Each output switches signals at 38.4 kBd (COM2) over unshielded cable up to 30 m, with a total cycle time of 2.4 ms. Good for sensor-level on/off, but not for high-speed pulse trains. Critical note: there is no electrical isolation between channels. Plan your encoder ground paths accordingly – a single ground fault on one output can pull down adjacent channels unless you use separate supplies from the master. ## Mounting and hookup Diagnostics via green/red LED and parameterizable diagnostic alarm. IODD file released.","metaTitle":"Siemens 6ES7143-5BF00-0BL0 IO-Link Module, 8 Out, 0.7 A, IP6","metaDescription":"Siemens 6ES7143-5BF00-0BL0 IO-Link module, 8 outputs, 0.7 A total, SIL 2, IP65/67, -30 to 55°C. Current production. RFQ for availability.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLC I/O & Expansion Modules"],"specifications":{"Max.":"55 °C","Min.":"-30 °C","Depth":"40 mm","Width":"30 mm","title":"6ES7143-5BF00-0BL0","Height":"159 mm","IODD file":"Yes","Lower Limit":"48 Ω","Port type B":"Yes","Upper Limit":"4 kΩ","description":"SIMATIC ET 200AL, IO-Link, DIQ 4+DQ 4x 24 V DC/0.5 A, 8x M8, Degree of protection IP67","2-Wire Sensor":"Yes","Short-circuit":"Yes; outputs to ground; encoder supply to ground; module by module","For Signal \"0\"":"-3 to +5V","For Signal \"1\"":"+11 to +30V","Weight, approx.":"125 g","lifecycle_stage":"current","Cycle time, min.":"2.4 ms","Diagnostic alarm":"Yes; Parameterizable","Firmware version":"V1.0.x","Power loss, typ.":"2.3 W","Rated value (DC)":"24 V","Unshielded, Max.":"30 m","Number of outputs":"8; Supply from 2UA+ of the IO-Link master","Transmission rate":"38.4 kBd (COM2)","On Lamp Load, Max.":"1 Hz","up to 55 °C, max.":"4","At \"0\" To \"1\", Max.":"4.8 ms","At \"0\" To \"1\", Min.":"1.2 ms","At \"1\" To \"0\", Max.":"4.8 ms","At \"1\" To \"0\", Min.":"1.2 ms","Between The Channels":"No","For Signal \"1\", Min.":"L+ (-0.8 V)","For Signal \"1\", Typ.":"3 mA","HW functional status":"FS01","IO-Link protocol 1.1":"Yes","Output current, max.":"0.7 A; Total current of all encoders (depending on IO-Link master supply via 2UA+)","Isolation tested with":"707 V DC (type test)","SIL acc. to IEC 62061":"SIL 2","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; green/red LED","IP degree of protection":"IP65/67","Current per module, max.":"4 A","Number of digital inputs":"4; Parameterizable as DIQ","Response threshold, typ.":"0.7 A","Short-circuit protection":"Yes; per channel, electronic","Between The Load Voltages":"Yes","Number of digital outputs":"8; 4 DQ fixed, 4 DIQ parameterizable","With Inductive Load, Max.":"0.5 Hz","With Resistive Load, Max.":"100 Hz","For Signal \"1\" Rated Value":"0.5 A","Supported IO-Link profiles":"common profile","For load voltage monitoring":"Yes; green LED","Reverse polarity protection":"Yes; Against destruction; encoder power supply outputs applied with reversed polarity, loads pick up","from load voltage 2L+, max.":"4 A; Maximum value","Device identifier (DeviceID)":"229382","Cable length unshielded, max.":"20 m","Substitute values connectable":"Yes; channel by channel, parameterizable","Category according to ISO 13849-1":"Cat. 3","Current consumption (rated value)":"15 mA; without load","permissible range, lower limit (DC)":"20.4 V","permissible range, upper limit (DC)":"28.8 V","For Signal \"0\" Residual Current, Max.":"0.5 mA","Size of process data, input per module":"1 byte","Size of process data, output per module":"1 byte","Type of electrical connection for IO-Link":"M12, 5-pin, A-coded","Performance level according to ISO 13849-1":"PL d","Limitation of inductive shutdown voltage to":"2L+ (-50 V)","Permissible Quiescent Current (2-Wire Sensor), Max.":"1.5 mA","Suitable for safety-related tripping of standard modules":"Yes; From FS01","Design of electrical connection for the inputs and outputs":"M8, 3-pole","Between The Channels And The Power Supply Of The Electronics":"Yes"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$277.96","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4be5f7dc7de6b0fd4e4c65ced3e1e52f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1430343&mlfb=6ES7143-5BF00-0BL0"},"ai":{"faq":[{"question":"What is the total output current for the 8 channels?","answer":"0.7 A total, supplied from the IO-Link master's 2UA+ rail. Per-channel current is not listed separately, so derate across all outputs."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7143-5BF00-0BL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7143-5BF00-0BL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}