{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7143-6BH00-0BB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7143-6BH00-0BB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7143-6BH00-0BB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7143-6BH00-0BB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens ET 200AL digital mixed module, order code 6ES7143-6BH00-0BB0, PROFINET IRT with 125 µs frame, 2x M12 D-coded ports, -40 to 60 °C, 16 DI, 16 DQ, per-channel diagnostics.","salesMarkdown":"The 6ES7143-6BH00-0BB0 is a mixed digital I/O module in the ET 200AL family, offering 16 inputs and 16 outputs on a compact 45 mm wide base. It communicates over PROFINET with full IRT support down to a 125 µs send cycle, making it suitable for isochronous motion or fast logic loops on the same bus. Both EtherNet/IP and Modbus TCP are also supported, so it can join non-Siemens controllers without a gateway. ## Connection and diagnostics Two M12 D-coded ports handle the network connection; the module itself is IP20-rated, designed for control cabinet mounting on a DIN rail. Each input channel monitors for wire-break below 0.3 mA, and each output is protected against short-circuit to M and P on a per-channel basis. Faults are indicated by a multicolour IO LED (red-green-yellow) and separate MS/NS/ERROR/MAINT LEDs. ## Data mapping and asset tags The input process data occupies 2 bytes plus 4 bytes of Quality Information that can be used for per-channel diagnostics without extra ladder logic. Outputs are packed into 2 bytes, split into two load groups of eight. I&M0 through I&M3 are supported, so maintenance and engineering records can store location, installation date, and service notes directly on the module — useful for large distributed cells where serial numbers alone don't tell the story. ## Temperature and compliance Full operating range from -40 to 60 °C ambient. The module supports shared-device configuration with up to two EtherNet/IP scanners.","metaTitle":"Siemens 6ES7143-6BH00-0BB0 ET 200AL IO, IRT, -40..60°C","metaDescription":"Siemens 6ES7143-6BH00-0BB0 ET 200AL digital mixed module with PROFINET IRT, 2x M12 ports, -40 to 60°C, DI/DQ, short-circuit and wire-break diagnostics. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLC Communication Modules"],"specifications":{"DI":"Yes","DQ":"Yes","ARP":"Yes","IRT":"Yes; 250 µs to 4 ms in 125 µs frame","MRP":"Yes","MSI":"Yes","MSO":"Yes","LLDP":"Yes","Max.":"60 °C","Min.":"-40 °C","SNMP":"Yes","Depth":"48 mm","Width":"45 mm","title":"6ES7143-6BH00-0BB0","Height":"200 mm","IO LED":"Yes; red-green-yellow LED","Inputs":"2 byte; + 4 bytes for QI information","MS LED":"Yes; green/red LED","NS LED":"Yes; green/red LED","TCP/IP":"Yes; (only EtherNet/IP or Modbus TCP)","Counter":"No","Outputs":"2 byte","RUN LED":"Yes; green LED","I&M data":"Yes; I&M0 to I&M3","M12 port":"Yes; 2x M12, 4-pin, D-coded","ERROR LED":"Yes; red LED","MAINT LED":"Yes; Yellow LED","PROFIsafe":"No","CIP Safety":"No","Modbus TCP":"Yes","Wire-break":"Yes; DI, input current < 0.3 mA, per channel","on S7-400H":"Yes","EtherNet/IP":"Yes","Lower Limit":"0.5 A: 48 ohms / 2 A: 12 ohms","Upper Limit":"4 kΩ","description":"SIMATIC ET 200eco PN, DIQ 16x 24 V DC/0.5 A/2 A, M12-L, 8x M12, double assignment, input type 3 (IEC 61131), sink input (PNP, sinking input), input delay 0.05..20 ms, source output (PNP,switching to P potential), substitute value output, channel diagnostics for: wire break at input, encoder power supply short-circuit, short-circuit at output, prioritized startup, MSI, MSO, MRP, S2 redundancy, I&M0...3, multi-fieldbus, PN IO, Ethernet IP, Modbus TCP, degree of protection IP67 / IP69K","Autocrossing":"Yes","For Uprating":"No","In Groups Of":"8; 2 load groups for 8 outputs each","2-Wire Sensor":"Yes","Shared device":"Yes; 2x EtherNet/IP Scanner","Short-circuit":"Yes; Outputs to M and P; channel by channel","on S7-1500R/H":"Yes","For Signal \"0\"":"-3 to +5V","For Signal \"1\"":"+11 to +30V","Interface type":"PROFINET with 100 Mbit/s full duplex (100BASE-TX)","Autonegotiation":"Yes","Number of ports":"2","Parameterizable":"Yes","Weight, approx.":"780 g","lifecycle_stage":"current","\"0\" To \"1\", Max.":"0.5 A: 100 µs / 2 A: 150 µs; at rated load","\"1\" To \"0\", Max.":"0.5 A: 150 µs / 2 A: 2.5 ms; at rated load","24 V DC circuits":"707 V DC (type test)","Current-sourcing":"Yes","Diagnostic alarm":"Yes; Parameterizable","Firmware version":"V5.1.x","Isochronous mode":"No","Power loss, typ.":"9.7 W","Rated value (DC)":"24 V","Unshielded, Max.":"30 m","H-Sync forwarding":"Yes","Integrated Switch":"Yes","Source/sink input":"P-reading","FW update possible":"Yes","Hardware interrupt":"Yes; Parameterizable","On Lamp Load, Max.":"1 Hz","PROFINET IO Device":"Yes","up to 60 °C, max.":"16","Prioritized startup":"Yes","Read Coils (Code=1)":"Yes","Between The Channels":"Yes","For Signal \"1\", Min.":"1L+ (-0.8 V) / 2L+ (-0.8 V)","For Signal \"1\", Typ.":"2.4 mA","HW functional status":"FS01","I/O request interval":"2 ms","Output current, max.":"100 mA; per output","Maintenance interrupt":"Yes; Parameterizable","Open IE communication":"Yes","SIL acc. to IEC 62061":"SIL 2","CIP Explicit Messaging":"Yes","CIP Implicit Messaging":"Yes","Channel status display":"Yes; green LED","Current per group, max.":"1L+: 2 A / 2L+: 6 A","DLR (Device Level Ring)":"No","For Channel Diagnostics":"Yes; red LED","IP degree of protection":"IP65/67/69K","Transmission rate, max.":"100 Mbit/s","Current per module, max.":"8 A","Number of digital inputs":"16; Parameterizable as DIQ","Response threshold, typ.":"0.5 A: 1 A / 2 A: 3 A","Short-circuit protection":"Yes; per channel, electronic","Between The Load Voltages":"Yes","LargeForwardOpen (Class3)":"No","Number of digital outputs":"16; Parameterizable as DIQ","With Inductive Load, Max.":"0.5 Hz","With Resistive Load, Max.":"0.5 A: 100 Hz / 2 A: 40 Hz","For Signal \"1\" Rated Value":"0.5 A / 2 A","Parameter change by master":"No","Write Single Coil (Code=5)":"Yes","Controlling a digital input":"Yes","For load voltage monitoring":"Yes; green LED","Reverse polarity protection":"Yes; against destruction","from load voltage 2L+, max.":"12 A; Maximum value","Device identifier (DeviceID)":"0306H","Modbus TCP Security Protocol":"No","Short-circuit encoder supply":"Yes; Per channel group","Connection display LINK TX/RX":"Yes; green LED, only link","Monitoring the supply voltage":"Yes","Number of PROFINET interfaces":"1","Read Discrete Inputs (Code=2)":"Yes","Substitute values connectable":"Yes","Address space per module, max.":"20 byte","Write Multiple Coils (Code=15)":"Yes","Access-consistent address space":"2 byte","Address space per station, max.":"20 byte","Design of electrical connection":"4/5-pin M12 circular connectors","Diagnostic information readable":"Yes","Digital inputs, parameterizable":"Yes","For Redundant Control Of A Load":"Yes","Number of connections per slave":"12","PROFINET system redundancy (R1)":"No","PROFINET system redundancy (S2)":"Yes","Read Holding Registers (Code=3)":"Yes","Requested Packet Interval (RPI)":"2 ms","between Ethernet and electronics":"Yes","Category according to ISO 13849-1":"Cat. 3","Current consumption (rated value)":"90 mA; without load","Supports protocol for PROFINET IO":"Yes","Between The Channels, In Groups Of":"8","Remark On Safety-Oriented Shutdown":"https://support.industry.siemens.com/cs/de/en/view/39198632","Write Multiple Registers (Code=16)":"Yes","permissible range, lower limit (DC)":"20.4 V","permissible range, upper limit (DC)":"28.8 V","For Signal \"0\" Residual Current, Max.":"0.1 mA","For Signal \"1\" Permissible Range, Max.":"0.5 A / 2 A","PROFINET from GSD version/GSD revision":"GSDML V2.3.x","Number of configurable submodules, max.":"2","Multi Fieldbus Configuration Tool (MFCT)":"from V1.3 SP1","Device ID according to ODVA (Product code)":"0FA8H","Performance level according to ISO 13849-1":"PL d","from load voltage 1L+ (unswitched voltage)":"12 A; Maximum value","Limitation of inductive shutdown voltage to":"0.5 A: Type 1L+ (-70 V) / 2 A: Type (-18 V)","Number of scanners with shared device, max.":"2","Manufacturer ID according to ODVA (VendorID)":"04E3H","Test voltage for interface, rms value [Vrms]":"1 500 V; According to IEEE 802.3","power supply according to NEC Class 2 required":"No","Number of IO Controllers with shared device, max.":"2","Design of electrical connection for supply voltage":"M12, 4-pin, L-coded","Permissible Quiescent Current (2-Wire Sensor), Max.":"1.5 mA","Ambient air temperature-barometric pressure-altitude":"Up to max. 5 000 m, at installation height > 2 000 m additional restrictions","STEP 7 TIA Portal configurable/integrated from version":"STEP 7 V17 or higher with HSP 0363","Suitable for safety-related tripping of standard modules":"Yes; From FS01","Design of electrical connection for the inputs and outputs":"M12, 5-pin, A-coded","Between The Channels And The Power Supply Of The Electronics":"8 channels are non-isolated and 8 channels are isolated from supply voltage 1L+"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$841.44","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/75930d7465278751508dfe5d7da2e87e.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1343059&mlfb=6ES7143-6BH00-0BB0"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7143-6BH00-0BB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7143-6BH00-0BB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}