{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7144-4GF01-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7144-4GF01-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7144-4GF01-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7144-4GF01-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC ET 200SP analog I/O module, 6ES7144-4GF01-0AB0, 4 inputs (0/4-20 mA, ±20 mA) + 4 outputs, 35 x 45 x 130 mm, diagnostics, wire-break and short-circuit detection.","salesMarkdown":"## Part at a glance The Siemens 6ES7144-4GF01-0AB0 is a SIMATIC ET 200SP analog I/O module packing 4 current inputs and 4 current outputs into a 35 mm deep housing – one of the slimmer slices in the ET 200SP family, so it fits tight DIN-rail rows without crowding the next slot. Inputs accept standard 0–20 mA, 4–20 mA, and bipolar ±20 mA, making it a straight drop-in for pressure, flow, or temperature transmitters on 4–20 mA loops, plus the occasional ±20 mA signal from a load cell or valve positioner. Wire-break detection is active on 4–20 mA channels only – a line-down fault fires a diagnostic alarm that tells maintenance exactly which loop dropped, no guessing. Each input channel converts in 1.1 ms; the module cycles all four inputs in 10 ms maximum. That means a PID loop updating every 10 ms is practical – fine for most process control, tight for fast motion axes. Input resistance is 50 Ω for both 0–20 mA and 4–20 mA ranges – same burden voltage as most two-wire transmitters expect, so no re-scaling at the field device. ## Power budget and isolation Draws 12 mA from the backplane bus and up to 40 mA from 24 V supply. Bulkhead isolation tested at 707 V DC type test between channels and backplane. Reverse-polarity protected against destruction, and each module carries electronic short-circuit protection referenced to frame ground.","metaTitle":"Siemens 6ES7144-4GF01-0AB0 SIMATIC ET 200SP 4 AI/4 AO","metaDescription":"Siemens SIMATIC ET 200SP analog I/O module, 4 inputs (0/4-20 mA, ±20 mA) and 4 outputs. 35 mm deep, diagnostics, wire-break detection. Quoted to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLC I/O & Expansion Modules"],"specifications":{"Depth":"35 mm","Width":"45 mm","Height":"130 mm","Step: low":"Yes; 4x cycle time","0 to 20 mA":"Yes","Step: High":"Yes; 64x cycle time","Step: None":"Yes; 1x cycle time","Wire-break":"Yes; at 4 to 20 mA","Step: Medium":"Yes; 16x cycle time","4 mA to 20 mA":"Yes","Short-circuit":"Yes; at 4 to 20 mA","Shielded, Max.":"30 m","Parameterizable":"Yes","Weight, approx.":"150 g","lifecycle_stage":"current","-20 mA to +20 mA":"Yes","Diagnostic alarm":"Yes; Parameterizable","Power loss, typ.":"1.1 W","Rated value (DC)":"24 V","Number of outputs":"4","Hardware interrupt":"Yes; (limit value alarm), can be parameterized for channel 0","up to 55 °C, max.":"1 A","Between The Channels":"No","Diagnostics function":"Yes","Group error SF (red)":"Yes","Integration time (ms)":"0,3 / 16,7 / 20 / 60","Isolation tested with":"707 V DC (type test)","Measurement principle":"integrating","Number of analog inputs":"4","Short-circuit protection":"Yes; per module, electronic to frame","Reverse polarity protection":"Yes; against destruction","Conversion time (per channel)":"1.1 ms","Input resistance (0 to 20 mA)":"50 Ω","from supply voltage 1L+, max.":"40 mA; Typical","Address space per module, max.":"8 byte","Cycle time (all channels) max.":"10 ms","Diagnostic information readable":"Yes","Input resistance (4 mA to 20 mA)":"50 Ω","Between the inputs and MANA (UCM)":"5 Vpp AC","from backplane bus 3.3 V DC, max.":"12 mA; Typical","Crosstalk between the inputs, min.":"-70 dB","Input resistance (-20 mA to +20 mA)":"50 Ω","Between The Channels And Backplane Bus":"Yes","Current, relative to input range, (+/-)":"0.075 %","Common mode interference (USS < 2.5 V), min.":"80 dB; Interference voltage < 5 V","For Current Measurement As 2-Wire Transducer":"Yes","For Current Measurement As 4-Wire Transducer":"Yes","Linearity error (relative to input range), (+/-)":"0.0075 %","Temperature error (relative to input range), (+/-)":"0.00075 %/K","Resolution with overrange (bit including sign), max.":"15 bit; 15 bit + sign at ±10 V, at ±5 V; 15 bit at 0 V to 10 V, at 1 V to 5 V","Interference voltage suppression for interference frequency f1 in Hz":"16,67 / 50 / 60 / 3 600","Permissible Input Current For Current Input (Destruction Limit), Max.":"40 mA","Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)":"0.004 %","Series mode interference (peak value of interference < rated value of input range), min.":"60 dB"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$177.80 – $521.27","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/12bef2b4e0e7fec51a170341121682d0.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=504643&mlfb=6ES7144-4GF01-0AB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7144-4GF01-0AB0/alternatives.json"},"ai":{"faq":[{"question":"What is the conversion time per channel?","answer":"1.1 ms per channel, with the full module cycle (all channels) completing in 10 ms maximum."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7144-4GF01-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7144-4GF01-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}