{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7146-5FF00-0BA0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7146-5FF00-0BA0","canonicalUrl":"https://aoctrl.com/siemens/6ES7146-5FF00-0BA0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7146-5FF00-0BA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC ET 200AL, F-DI 4+F-DQ 2x24VDC/2A, 4xM12, PROFIsafe, up to PL e (ISO 13849), up to SIL 3 (IEC 61508), IP67.","salesMarkdown":"## Fail-safe I/O slice for distributed safety zones The Siemens 6ES7146-5FF00-0BA0 is a compact ET 200AL fail-safe I/O module combining 4 fail-safe digital inputs and 2 fail-safe digital outputs in a single IP67-rated block with 4xM12 connectors. The safety outputs switch at 24 VDC and are rated 2 A per channel, with overload and short-circuit protection built in. The inputs detect signal \"1\" from +15 to +30 VDC with a typical current draw of 4.85 mA at 24 V, making them compatible with standard 3-wire PNP safety sensors and e-stops. ## Fit and integration constraints Ambient range is -30 °C to +55 °C with no derating on the outputs up to the full 4 A total (2 x 2 A) at 55 °C. The 4.7 W typical power loss stays within the thermal budget of a sealed IP67 enclosure, but if the module is inside a non-ventilated junction box on a hot factory floor, that 4.7 W plus heat from adjacent blocks should be summed against the box's dissipation rating. For volume or scheduled releases, the RFQ should specify the annual quantity and preferred delivery cadence. ## Diagnostics and commissioning detail The module supports I&M data (I&M0 to I&M3) and a parameterizable diagnostic alarm, so the PROFIsafe controller reads the module identity and fault history without a field visit. Input and output filter times are adjustable from 0.8 ms to 12.8 ms for both rising and falling edges — set to 0.8 ms for fast safety sensors or 12.8 ms to debounce a mechanical e-stop contact. Wire-break detection is active on the outputs when they are off (switched to 0), and the module detects short-circuits on inputs, outputs, and the encoder supply. The 8-byte input and 6-byte output process image maps directly into the safety program's F-runtime group.","metaTitle":"Siemens 6ES7146-5FF00-0BA0 ET 200AL F-DI 4+F-DQ 2, SIL 3","metaDescription":"Siemens 6ES7146-5FF00-0BA0 fail-safe I/O module for ET 200AL. 4 fail-safe inputs, 2 fail-safe outputs at 24 VDC/2 A, SIL 3 / PL e. IP67, M12, PROFIsafe.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLC I/O & Expansion Modules"],"specifications":{"DI":"Yes","DQ":"Yes","Max.":"55 °C","Min.":"-30 °C","Depth":"40 mm","Width":"45 mm","title":"6ES7146-5FF00-0BA0","Height":"159 mm","Inputs":"8 byte","Outputs":"6 byte","I&M data":"Yes; I&M0 to I&M3","Wire-break":"Yes; outputs when off","Lower Limit":"12 Ω","Upper Limit":"2 kΩ","description":"SIMATIC DP, ET 200AL, F-DI 4+F-DQ 2x24VDC/2A, 4xM12, PROFIsafe, up to PL e (ISO 13849), Up to SIL 3 (IEC 61508), Degree of protection IP67","In Groups Of":"2","2-Wire Sensor":"No","ET-Connection":"M8, 4-pin, shielded","Short-circuit":"Yes; inputs, outputs, encoder supply","For Signal \"0\"":"-30 to +5 V","For Signal \"1\"":"+15 to +30 V","Parameterizable":"Yes","Weight, approx.":"220 g","lifecycle_stage":"current","Diagnostic alarm":"Yes; Parameterizable","Firmware version":"V1.0.x","Power loss, typ.":"4.7 W","Rated value (DC)":"24 V","Unshielded, Max.":"30 m","Number of outputs":"2","On Lamp Load, Max.":"10 Hz","up to 55 °C, max.":"4","At \"0\" To \"1\", Max.":"12.8 ms","At \"0\" To \"1\", Min.":"0.8 ms","At \"1\" To \"0\", Max.":"12.8 ms","At \"1\" To \"0\", Min.":"0.8 ms","Overload protection":"Yes","For Signal \"1\", Min.":"L+ (-2.0 V), P-switch is L+ (-1.5 V), M-switch is 0.5 V","For Signal \"1\", Typ.":"4.85 mA","HW functional status":"FS01","Output current, max.":"1 A; total current of all encoders, max. 0.5 A per load voltage; maximum of 2.0 V drop","Isolation tested with":"707 V DC (type test)","SIL acc. to IEC 61508":"SIL 2 (DI single-channel), SIL 3 (DI two-channel, DQ)","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; green/red LED","Open-circuit detection":"Yes; per channel, only detects when output is off","Current per group, max.":"4 A","For Channel Diagnostics":"Yes; red LED","IP degree of protection":"IP65/67","Number of digital inputs":"4","Response threshold, typ.":"3.4 A; measured at P-switch","Short-circuit protection":"Yes; per channel, electronic","Between The Load Voltages":"Yes","Number of digital outputs":"2","With Inductive Load, Max.":"0.1 Hz","With Resistive Load, Max.":"30 Hz","For Signal \"1\" Rated Value":"2 A","For load voltage monitoring":"Yes; green LED","Reverse polarity protection":"Yes; against destruction; outputs applied with reversed polarity for loads connected between M-switch and 2L+ will conduct","from load voltage 2L+, max.":"4 A; Maximum value","Monitoring the supply voltage":"Yes","Substitute values connectable":"No","Category according to ISO 13849-1":"Cat. 3 (DI single-channel), Cat. 4 (DI two-channel, DQ)","Current consumption (rated value)":"55 mA (1L+) / 40 mA (2L+); without load","Between The Channels, In Groups Of":"4 DI channels are isolated from 2 DQ channels","permissible range, lower limit (DC)":"20.4 V","permissible range, upper limit (DC)":"28.8 V","For Signal \"0\" Residual Current, Max.":"0.5 mA","Between The Channels And Backplane Bus":"Yes","Performance level according to ISO 13849-1":"PLd (DI single-channel), PLe (DI two-channel, DQ)","from load voltage 1L+ (unswitched voltage)":"4 A; Maximum value","Input characteristic according to IEC 61131":"Type 1","Limitation of inductive shutdown voltage to":"P-switch: -26 V DC referenced to 2M, M-switch: +48 V DC referenced to 2M","power supply according to NEC Class 2 required":"No","Low demand mode: PFDavg in accordance with SIL2":"< 1.00E-03 DI single-channel; < 1.00E-03 DQ with dark test disabled","Low demand mode: PFDavg in accordance with SIL3":"< 1.00E-05 DI two-channel; < 2.00E-05 DQ with dark test enabled","Design of electrical connection for supply voltage":"M8, 4-pin","Permissible Quiescent Current (2-Wire Sensor), Max.":"0.5 mA","STEP 7 TIA Portal configurable/integrated from version":"STEP 7 V17 or higher","High demand/continuous mode: PFH in accordance with SIL2":"< 1.00E-08 1/h DI single-channel; < 1.00E-07 1/h DQ with dark test disabled","High demand/continuous mode: PFH in accordance with SIL3":"< 1.00E-09 1/h DI two-channel; < 1.00E-08 1/h DQ with dark test enabled","Design of electrical connection for the inputs and outputs":"M12, 5-pole","Between The Channels And The Power Supply Of The Electronics":"DI channels are non-isolated from supply voltage 1L+ and DQ channels are isolated from the supply voltage 1L+"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$259.08","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/eaa2d09cb181f4f534f179bc0da588d0.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1399321&mlfb=6ES7146-5FF00-0BA0"},"ai":{"faq":[{"question":"Is 6ES7146-5FF00-0BA0 a safety module?","answer":"Yes — it is a fail-safe I/O module (F-DI 4 + F-DQ 2) certified to SIL 3 per IEC 61508 and PL e per ISO 13849, and communicates via PROFIsafe."},{"question":"What is the SIL rating of 6ES7146-5FF00-0BA0?","answer":"SIL 3 per IEC 61508 and PL e per ISO 13849 — suitable for safety functions up to the highest performance level in most machinery directives."},{"question":"Does 6ES7146-5FF00-0BA0 work with S7-1500?","answer":"Yes — as an ET 200AL remote I/O slice, it connects to any PROFINET controller that supports PROFIsafe, including the S7-1500 family with a suitable F-CPU."},{"question":"What is the difference between 6ES7146-5FF00-0BA0 and 6ES7146-5FF00-0BA1?","answer":"The evidence does not specify the differences between these two order codes. The -0BA0 variant carries hardware functional status FS01 and firmware V1.0.x. Confirm the exact hardware revision required for your BOM against the Siemens compatibility matrix before ordering."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7146-5FF00-0BA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7146-5FF00-0BA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}