{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7151-3BA50-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7151-3BA50-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7151-3BA50-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7151-3BA50-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC DP, Interface module IM 151-3 PN HS for ET 200S, 100 Mbit/s, 2x RJ45, 200 byte inputs/outputs, current spare part.","salesMarkdown":"## Spare part designation and lifecycle status The 6ES7151-3BA50-0AB0 is explicitly designated a spare part in the SIMATIC DP line, serving as the IM 151-3 PN HS interface module for the ET 200S distributed I/O system. ## PROFINET performance and I/O capacity This interface module supports PROFINET IO with a maximum transmission rate of 100 Mbit/s and includes two RJ45 ports for line or star topology connections. It handles 200 bytes each of process input and output data, which sets the ceiling for the number and type of ET 200S electronic modules the head station can address without exceeding the bus cycle budget. Isochronous mode is supported, enabling deterministic equidistant cycle synchronization for motion-control and high-speed process applications where jitter must stay below the bus cycle. ## Diagnostics and status indication Onboard diagnostics include a group error SF (red) LED, bus fault BF (red) LED, and a LINK (green) LED per RJ45 port, plus a 24 V supply monitoring LED — enough to localise a fault to the backplane bus, the Ethernet link, or the field-side supply without a programming device. Galvanic isolation exists between the Ethernet interface and the electronics, but not between the backplane bus and the electronics, nor between the supply voltage and the electronics — a distinction that matters when planning surge protection zones in the cabinet. ## Power budget and physical fit The module draws up to 350 mA from the 24 V field supply (1L+) and 0.7 A from the 5 V backplane bus, with a typical power loss of 6 W — the backplane current is the tighter constraint when chaining multiple active bus modules on one ET 200S segment.","metaTitle":"Siemens 6ES7151-3BA50-0AB0 IM 151-3 PN HS, 100 Mbit/s","metaDescription":"Siemens 6ES7151-3BA50-0AB0 IM 151-3 PN HS interface module for ET 200S. 100 Mbit/s PROFINET, 2x RJ45, 200 byte I/O. Current spare part, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLC Communication Modules"],"specifications":{"Depth":"75 mm","Width":"60 mm","Alarms":"Yes","Height":"119.5 mm","Inputs":"200 byte","Outputs":"200 byte","Weight, approx.":"160 g","lifecycle_stage":"current","Isochronous mode":"Yes","Power loss, typ.":"6 W","Bus fault BF (red)":"Yes","Diagnostics function":"Yes","Group error SF (red)":"Yes","Number of RJ45 ports":"2","Transmission rate, max.":"100 Mbit/s","Device identifier (DeviceID)":"301H","from supply voltage 1L+, max.":"350 mA","between Ethernet and electronics":"Yes","for backplane bus (5 V DC), max.":"0.7 A; 3.5 V DC","Supports protocol for PROFINET IO":"Yes","Connection to network LINK (green)":"Yes","Between Backplane Bus And Electronics":"No","Between Supply Voltage And Electronics":"No","Automatic Detection Of Transmission Rate":"Yes","Mains/voltage failure stored energy time":"20 ms","Monitoring 24 V voltage supply ON (green)":"Yes"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$299.72","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/599fb3d3d8592ec955b0ddbf0a810439.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=454791&mlfb=6ES7151-3BA50-0AB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7151-3BA50-0AB0/alternatives.json"},"ai":{"faq":[{"question":"Can 6ES7151-3BA50-0AB0 be used with all ET 200S I/O modules?","answer":"The IM 151-3 PN HS supports up to 32 I/O modules across a maximum 2 m width of the ET 200S station, with 200 bytes each of input and output data — the practical limit is the sum of the module widths and the total process image size, not a per-module compatibility restriction."},{"question":"What is the difference between 6ES7151-3BA50-0AB0 and 6ES7151-3BA50-0AB1?","answer":"The evidence on file does not cover the -0AB1 variant. The 6ES7151-3BA50-0AB0 is the current spare-part revision of the IM 151-3 PN HS; verify the exact order code against your BOM before committing."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7151-3BA50-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7151-3BA50-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}