{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7151-3BA60-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7151-3BA60-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7151-3BA60-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7151-3BA60-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC ET 200S IM 151-3 PN interface module, order code 6ES7151-3BA60-0AB0, two PROFINET ports at 100 Mbit/s, IRT/MRP/LLDP capable, 0 °C to 60 °C, lifecycle current.","salesMarkdown":"## Head module in one paragraph The 6ES7151-3BA60-0AB0: The PROFINET stack on this head carries IRT, MRP, LLDP, ARP, SNMP and PROFIenergy, with prioritized startup and shared-device mode — that combination is what makes it usable on a mixed motion-and-standard line rather than only a basic remote I/O drop. Diagnostics surface as the standard BF (red, bus fault) and SF (red, group error) LEDs, a LINK LED per port, and an alarm channel into the controller via dataset. ## What the ratings actually gate Supply draw peaks at 200 mA from 1L+ with 20 ms of stored energy; Ethernet-to-electronics isolation tested at 500 V. The module itself does not isolate the backplane bus from the electronics nor the supply from the electronics — that isolation has to live in the chosen power module and the I/O modules behind it, which is worth confirming before stacking in a noisier cabinet. Per-module I/O budgets are 256 byte input and 256 byte output, which lines up with what the standard ET 200S power modules can feed — going beyond that is a station design issue, not a head-module issue. CE and UL approvals are marked on the device, which is what the documentation buyer needs to clear a customs or end-customer audit on a European or North American machine.","metaTitle":"Siemens 6ES7151-3BA60-0AB0 IM151-3 PN, 100 Mbit/s","metaDescription":"Siemens 6ES7151-3BA60-0AB0 ET 200S interface module, PROFINET, 100 Mbit/s, 2 ports, IRT/MRP/LLDP, lifecycle_stage current. Quoted against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLC Communication Modules"],"specifications":{"ARP":"Yes","IRT":"Yes","MRP":"Yes","LLDP":"Yes","Max.":"60 °C","Min.":"0 °C","Ping":"Yes","SNMP":"Yes","Depth":"75 mm; with mounting rail","Width":"60 mm","title":"6ES7151-3BA60-0AB0","Alarms":"Yes","Height":"119.5 mm","Inputs":"256 byte","CE mark":"Yes","Outputs":"256 byte","LINK LED":"Yes","PROFIenergy":"Yes","UL approval":"Yes","Via Dataset":"Yes","description":"*** spare part *** SIMATIC DP, interface module IM 151-3 PN HS for ET 200S transmission rate 100 Mbit/s max. 32 I/O modules up to 2 m width can be connected; 2x bus connections via RJ45 incl. termination module","Autocrossing":"Yes","Shared device":"Yes","Autonegotiation":"Yes","Number of ports":"2","Weight, approx.":"150 g","lifecycle_stage":"current","Power loss, typ.":"2 W","RJ 45 (Ethernet)":"Yes","Bus fault BF (red)":"Yes","Prioritized startup":"Yes","Diagnostics function":"Yes","Group error SF (red)":"Yes","Isolation tested with":"500 V","Transmission rate, max.":"100 Mbit/s","Number of PROFINET interfaces":"1","from supply voltage 1L+, max.":"200 mA","between Ethernet and electronics":"Yes","Supports protocol for PROFINET IO":"Yes","Between Backplane Bus And Electronics":"No","Between Supply Voltage And Electronics":"No","Mains/voltage failure stored energy time":"20 ms","Monitoring 24 V voltage supply ON (green)":"Yes","Number of IO Controllers with shared device, max.":"2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$497.21 – $697.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/599fb3d3d8592ec955b0ddbf0a810439.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=266899&mlfb=6ES7151-3BA60-0AB0"},"ai":{"faq":[{"question":"Which PROFINET features does this head actually support?","answer":"IRT, MRP, LLDP, ARP, SNMP, PROFIenergy, prioritized startup and shared-device mode are all listed, with two ports on one PROFINET interface at 100 Mbit/s."},{"question":"What compliance marks does the module carry?","answer":"CE and UL approvals are marked on the device; isolation between the Ethernet port and the electronics is tested at 500 V."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7151-3BA60-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7151-3BA60-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}