{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7155-5BA00-0AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7155-5BA00-0AB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7155-5BA00-0AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7155-5BA00-0AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens ET 200S PROFIBUS DP interface module, 6ES7155-5BA00-0AB0, DPV1 slave, RS485, 12 Mbit/s, 24 VDC, I2t 0.09 A²·s.","salesMarkdown":"## Fieldbus Integration The 6ES7155-5BA00-0AB0: Diagnostic functions and alarms are enabled, with I&M data up to I&M3 for asset identification. Three status LEDs (RUN green, ERROR red, MAINT yellow) give quick panel-side feedback. Connection status is indicated by a green DP LED. ## Panel Layout Constraints Width is 35 mm, height 147 mm, depth 129 mm. Module mounts in an ET 200S rack and supports up to 12 I/O modules per group. Horizontal installation rated for 0–60 °C; vertical orientation derates to 40 °C maximum. Supply input is 24 VDC with reverse-polarity and short-circuit protection. Maximum inrush is 4 A; steady-state power loss is 4 W. At minimum operating voltage (20.4 V DC) with full load, current consumption reaches 1.2 A. Isolation tested at 707 V DC type test. Firmware revision is V2.0.0, which matches the latest commercially shipped level.","metaTitle":"Siemens 6ES7155-5BA00-0AB0 ET 200S PROFIBUS DP, 12 Mbit/s, D","metaDescription":"PROFIBUS DP V1 slave interface module for ET 200S. Active production. 12 Mbit/s, RS485, I2t 0.09 A²·s, 24 VDC, 4 W. Sourced to order. RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLC Communication Modules"],"specifications":{"I2t":"0.09 A²·s","DPV1":"Yes","Depth":"129 mm","Width":"35 mm","Alarms":"Yes","Height":"147 mm","RS 485":"Yes","TCP/IP":"No","RUN LED":"Yes; green LED","I&M data":"Yes; I&M0 to I&M3","ERROR LED":"Yes; red LED","MAINT LED":"Yes; Yellow LED","Via Dataset":"No","Via User Data":"No","via BU/BA Send":"No","SYNC capability":"Yes","Weight, approx.":"360 g","lifecycle_stage":"current","Firmware version":"V2.0.0","Isochronous mode":"No","Power loss, typ.":"4 W","Rated value (DC)":"24 V","Status indicator":"Yes","FREEZE capability":"Yes","PROFIBUS DP slave":"Yes","Diagnostics function":"Yes","HW functional status":"From FS01","Inrush current, max.":"4 A","Connection display DP":"Yes; green LED","Isolation tested with":"707 V DC (type test)","Modules per rack, max.":"12; I/O modules","Integrated power supply":"Yes","Transmission rate, max.":"12 Mbit/s","Short-circuit protection":"Yes","Current consumption, max.":"1.2 A; at 20.4 V DC and max. load","Reverse polarity protection":"Yes","Vertical Installation, Max.":"40 °C","Vertical Installation, Min.":"-25 °C; from FS04","from interface 5 V DC, max.":"80 mA","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"-25 °C; from FS04","Number of PROFIBUS interfaces":"1","Address space per module, max.":"32 byte; per input / output","Address space per station, max.":"244 byte; per input / output","Current consumption (rated value)":"0.2 A; at 24 V DC and without load","Infeed power to the backplane bus":"14 W","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Number of permissible power segments":"1","Between Backplane Bus And Electronics":"No","Between Supply And All Other Circuits":"No","PROFIBUS from GSD version/GSD revision":"V1.0 / V5.1","Mains/voltage failure stored energy time":"5 ms","Installation altitude above sea level, max.":"5 000 m; Restrictions for installation altitudes > 2 000 m, see manual","STEP 7 configurable/integrated from version":"V5.5 SP3 / -","Module swapping during operation (hot swapping)":"No","System power supply can be plugged in to left of IM":"No","between PROFIBUS DP and all other circuit components":"Yes","STEP 7 TIA Portal configurable/integrated from version":"V13 / V13"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$213.36 – $541.92","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5c346fdcf8ea4d813e11c8f7eba21985.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=171297&mlfb=6ES7155-5BA00-0AB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7155-5BA00-0AB0/alternatives.json"},"ai":{"faq":[{"question":"What does the I2t rating of 0.09 A²·s mean for protection coordination?","answer":"The I2t value of 0.09 A²·s is a thermal energy limit used to size upstream fuses or breakers, ensuring the module withstands fault current without damage during short-circuit events."},{"question":"Does the module support DPV1?","answer":"Yes, it supports DPV1, which allows extended diagnostic and alarm data transmission beyond cyclic DP-V0 communication."},{"question":"What is the maximum PROFIBUS speed?","answer":"The module operates at up to 12 Mbit/s on RS485."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7155-5BA00-0AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7155-5BA00-0AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}