{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7193-6BP00-0DA1","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7193-6BP00-0DA1","canonicalUrl":"https://aoctrl.com/siemens/6ES7193-6BP00-0DA1","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7193-6BP00-0DA1","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC ET 200SP BaseUnit BU15-P16+A0+2D/T, Type A1, 15 x 117 mm, push-in terminals, no AUX terminals, new load group, temperature acquisition.","salesMarkdown":"## What this BaseUnit does in the ET 200SP system The Siemens 6ES7193-6BP00-0DA1 is a SIMATIC ET 200SP BaseUnit, Type A1. It provides the mechanical and electrical connection for one I/O module in a distributed I/O node. The 15 mm width occupies one slot on the mounting rail. It supplies 16 process terminals to the I/O module, has no AUX bus terminals, and includes an integrated temperature sensor. ## Key specs that decide fit Width is the fit-critical dimension here — at 15 mm, this BaseUnit takes one slot on the DIN rail. If your panel layout was calculated for 15 mm ET 200SP slots, this drops right in. Depth is 35 mm, height is 117 mm. The push-in terminal type means you terminate solid or ferruled stranded wire (0.14 to 2.5 mm², AWG 26 to 14) without a screwdriver — tool-free, which saves time on a multi-slice build. Electrically, the BaseUnit passes 24 V DC on the and bus bars at up to 10 A. The process terminals (16 of them, connecting to the I/O module) are rated at 2 A max. It creates a new potential group — meaning the load group isolation starts here, not continued from the left. The integrated temperature sensor reports back to the system, letting the controller monitor for overheating conditions inside the enclosure. Environmental limits: horizontal installation allows up to 60 °C, vertical up to 50 °C. Minimum operating temperature is -30 °C in both orientations. Installation altitude goes to 5 000 m with derating above 2 000 m per the manual. Isolation is type-tested at 707 V DC between the potential groups and the backplane bus. ## Temperature sensor — what it buys you in the field The integrated temperature sensor is a diagnostic feature, not a control input. It reports the BaseUnit's internal temperature back to the ET 200SP interface module. On a commissioning call, if you see a thermal warning from this slice, you know the enclosure ventilation or ambient conditions need attention before the I/O module starts dropping signals. It's one less thing to troubleshoot blind.","metaTitle":"Siemens 6ES7193-6BP00-0DA1 SIMATIC ET 200SP BaseUnit, 15 mm,","metaDescription":"SIMATIC ET 200SP BaseUnit BU15-P16+A0+2D/T, Type A1, 15 mm width, push-in terminals, 24 V DC, 10 A bus rating, active production. Order code 6ES7193-6BP00-0DA1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLC I/O & Expansion Modules"],"specifications":{"Depth":"35 mm","Width":"15 mm","Height":"117 mm","Terminal type":"Push-in terminal","Number of slots":"1; Type A1","Weight, approx.":"40 g","lifecycle_stage":"current","Rated value (DC)":"24 V","for AUX terminals":"does not exist","Temperature sensor":"Yes","New potential group":"Yes","For Add-On Terminals":"does not exist","HW functional status":"FS10 and higher","For Process Terminals":"CC00 to CC09","Isolation tested with":"707 V DC (type test)","For P1 and P2 bus, max.":"10 A","Number of add-on terminals":"0","For process terminals, max.":"2 A","Vertical Installation, Max.":"50 °C","Vertical Installation, Min.":"-30 °C","Between The Potential Groups":"Yes","Conductor cross-section, max.":"2.5 mm²; AWG 14","Conductor cross-section, min.":"0.14 mm²; AWG 26","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"-30 °C","Number of terminals to AUX bus":"0","System-Integrated Shield Connection":"Yes; Optional","Potential group continued from the left":"No","Number of process terminals to I/O module":"16","External Protection For Power Supply Lines":"Yes; 24 V DC/10 A miniature circuit breaker with type B or C tripping characteristic","Installation altitude above sea level, max.":"5 000 m; Restrictions for installation altitudes > 2 000 m, see manual","Number of terminals with connection to P1 and P2 bus":"2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$26.67","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9e9858a40ce4f037003e37d04137d573.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=650&mlfb=6ES7193-6BP00-0DA1","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7193-6BP00-0DA1/alternatives.json"},"ai":{"faq":[{"question":"Will this BaseUnit work with a 6ES7522-1BH01-0AB0 digital output module?","answer":"No — those are different systems. The 6ES7193-6BP00-0DA1 is an ET 200SP BaseUnit (15 mm width, Type A1), while the 6ES7522-1BH01-0AB0 is a S7-1500 digital output module that mounts on a 35 mm wide S7-1500 BaseUnit. The form factors, bus interfaces, and mounting rails are incompatible. You cannot drop one into the other's panel without rewiring the entire slice."},{"question":"What are the key dimensions for panel layout?","answer":"Width is 15 mm (one ET 200SP slot), depth is 35 mm, height is 117 mm. The 15 mm width is the critical dimension for slot count on the DIN rail."},{"question":"What wire sizes does the push-in terminal accept?","answer":"Solid or ferruled stranded wire from 0.14 mm² to 2.5 mm² (AWG 26 to AWG 14). No screwdriver needed for termination."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7193-6BP00-0DA1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7193-6BP00-0DA1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}