{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7215-1AG40-0XB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7215-1AG40-0XB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7215-1AG40-0XB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7215-1AG40-0XB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens S7-1200 CPU 1215C, 6ES7215-1AG40-0XB0, 24 V DC, PROFINET, OPC UA Server, -40 to 70 °C, cULus, CE.","salesMarkdown":"The built-in OPC UA server (yes, listed as OPC UA Server) means you can expose process data directly to higher-level systems without a separate gateway — saves panel space and one license. The MRP support lets you wire the PROFINET port into a redundant ring for line uptime; just note IRT (isochronous real-time) is not supported, so this CPU is not for motion drives requiring tight synchronization. ## Sourcing and compliance notes Specify this CPU into your BOM; we will quote it to order. No lifecycle notification has been issued; treat it as current catalog. The cULus and CE marks cover most global panel builds; for RoHS/REACH declarations, request the Siemens compliance pack with your order.","metaTitle":"Siemens 6ES7215-1AG40-0XB0, CPU 1215C, PROFINET, -40..70°C","metaDescription":"Siemens 6ES7215-1AG40-0XB0 CPU 1215C with 24V DC, PROFINET, OPC UA Server, MRP, and wide temp range. Available to order. cULus and CE marked.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"DCP":"Yes","FBD":"Yes","I2t":"0.5 A²·s","IRT":"No","LAD":"Yes","MRP":"Yes; as MRP redundancy manager and/or MRP client","SCL":"Yes","UDP":"Yes","24 V":"L+ minus 4 V DC min.","DHCP":"No","LLDP":"Yes","MRPD":"No","Max.":"70 °C","Min.":"-40 °C","SNMP":"Yes","Depth":"75 mm","Width":"130 mm","cULus":"Yes","Height":"100 mm","MODBUS":"Yes","OPC UA":"Yes; OPC UA Server","TCP/IP":"Yes","24 V DC":"Yes","CE mark":"Yes","Forcing":"Yes","Overall":"PG Connections: 4 reserved / 4 max; HMI Connections: 12 reserved / 18 max; S7 Connections: 8 reserved / 14 max; Open User Connections: 8 reserved / 14 max; Web Connections: 2 reserved / 30 max; OPC UA Connections: 0 reserved / 10 max; Total Connections: 34 reserved / 64 max","Present":"Yes","Voltage":"Yes","Isolated":"Yes","PROFIBUS":"Yes; CM 1243-5 (master) or CM 1242-5 (slave) required","As Client":"Yes","As Server":"Yes","ERROR LED":"Yes","MAINT LED":"Yes","PROFIsafe":"No","Supported":"Yes","Variables":"Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters","0 to +10 V":"Yes","0 to 20 mA":"Yes","Adjustable":"Yes","Integrated":"4 Mbyte","S7 routing":"Yes","Size, max.":"8 kbyte; Size of bit memory address area","Web server":"Yes","Backup time":"480 h; Typical","FM approval":"Yes","KC approval":"Yes","PROFIenergy":"Yes","UL approval":"Yes","AS-Interface":"Yes; CM 1243-2 required","Autocrossing":"Yes","Number, max.":"Limited only by RAM for code","RUN/STOP LED":"Yes","2-Wire Sensor":"Yes","OPC UA Server":"Yes; data access (read, write, subscribe), method call, runtime license required","Shared device":"Yes","Updating time":"The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data.","For Signal \"0\"":"5 V DC at 1 mA","For Signal \"1\"":"15 V DC at 2.5 mA","Interface type":"PROFINET","PID controller":"Yes","Shielded, Max.":"100 m; twisted and shielded","Autonegotiation":"Yes","Copy protection":"Yes","Marine approval":"Yes","Number of ports":"2","Operation, max.":"95 %; no condensation","Operation, min.":"795 hPa","Parameterizable":"Single phase: 3 @ 100 kHz & 3 @ 30 kHz, differential: 3 @ 80 kHz & 3 @ 30 kHz","Weight, approx.":"500 g","Without Battery":"Yes","lifecycle_stage":"current","\"0\" To \"1\", Max.":"1 µs","\"1\" To \"0\", Max.":"5 µs","Block protection":"Yes","Firmware version":"V4.5","Isochronous mode":"No","Maintenance-Free":"Yes","Media redundancy":"Yes","Power loss, typ.":"12 W","RJ 45 (Ethernet)":"Yes","Rated value (DC)":"24 V","Unshielded, Max.":"150 m","Data length, max.":"1 472 byte","Fall height, max.":"0.3 m; five times, in product package","Integrated Switch":"Yes","Source/sink input":"Yes","Inputs, adjustable":"1 kbyte","Number of counters":"6","On Lamp Load, Max.":"5 W","PROFINET IO Device":"Yes","up to 40 °C, max.":"14","At \"0\" To \"1\", Max.":"12.8 ms","At \"0\" To \"1\", Min.":"0.2 ms","Outputs, adjustable":"1 kbyte","PG/OP communication":"Yes; encryption with TLS V1.3 pre-selected","Prioritized startup":"Yes","Programming package":"STEP 7 V17 or higher","User authentication":"\"anonymous\" or by user name & password","Between The Channels":"No","For Signal \"0\", Max.":"0.1 V; with 10 kOhm load","For Signal \"1\", Min.":"20 V","ISO-on-TCP (RFC1006)":"Yes","Inrush current, max.":"12 A; at 28.8 V DC","Frequency measurement":"Yes","Open IE communication":"Yes; Optionally also encrypted","RCM (formerly C-TICK)":"Yes","SIMATIC communication":"Yes","User-defined websites":"Yes","Controlled Positioning":"Yes","Number of alarm inputs":"4","Of Which In Line, Max.":"16","PROFINET IO Controller":"Yes","Deviation per day, max.":"±60 s/month at 25 °C","IP degree of protection":"IP20","Limit frequency (pulse)":"100 kHz","Number of analog inputs":"2","Number of pulse outputs":"4","Number of relay outputs":"0","Sampling interval, min.":"100 ms","Status/control variable":"Yes","Storage/transport, max.":"1 080 hPa","Storage/transport, min.":"660 hPa","Transmission rate, max.":"100 Mbit/s","User data per job, max.":"See online help (S7 communication, user data size)","Counting frequency, max.":"100 kHz","For Bit Operations, Typ.":"0.08 µs; / instruction","Number of analog outputs":"2","Number of blocks (total)":"DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used","Number of digital inputs":"14; Integrated","Number of sessions, max.":"10","Per Priority Class, Max.":"16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB","Runtime license required":"Yes; \"Basic\" license required","Current consumption, max.":"1 500 mA; CPU with all expansion modules","For Word Operations, Typ.":"1.7 µs; / instruction","Number of digital outputs":"10","Publishing interval, min.":"200 ms","With Resistive Load, Max.":"0.5 A","Application authentication":"Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256","For Signal \"1\" Rated Value":"0.5 A","Hardware clock (real-time)":"Yes","Installation altitude, max.":"5 000 m; Restrictions for installation altitudes > 2 000 m, see manual","Installation altitude, min.":"-1 000 m","Memory size per trace, max.":"512 kbyte","Of Which High-Speed Outputs":"4; 100 kHz Pulse Train Output","Reverse polarity protection":"Yes","Vertical Installation, Max.":"50 °C","Vertical Installation, Min.":"-20 °C","Input resistance (0 to 10 V)":"≥100k ohms","Conversion time (per channel)":"625 µs","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"-20 °C","Number of configurable Traces":"2","Test voltage at air discharge":"8 kV","Number of server methods, max.":"20","for backplane bus (5 V DC), max.":"1 600 mA; Max. 5 V DC for SM and CM","Current consumption (rated value)":"500 mA; CPU only","Integration time, parameterizable":"Yes","Number of server interfaces, max.":"2","Supports protocol for PROFINET IO":"Yes","Test voltage at contact discharge":"6 kV","Between The Channels, In Groups Of":"1","Number of modules per system, max.":"3 comm. modules, 1 signal board, 8 signal modules","Protection level: Write protection":"Yes","tested according to IEC 60068-2-27":"Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms","For Floating Point Arithmetic, Typ.":"2.3 µs; / instruction","Plug-in (SIMATIC Memory Card), max.":"with SIMATIC memory card","Potential separation digital inputs":"No","permissible range, lower limit (DC)":"20.4 V","permissible range, upper limit (DC)":"28.8 V","Potential separation digital outputs":"Yes","SO2 at RH < 60% without condensation":"S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free","Activation/deactivation of IO Devices":"Yes","For Signal \"0\" Residual Current, Max.":"0.1 mA","Protection level: Complete protection":"Yes","Number of connectable IO Devices, max.":"16","Protection level: Read/write protection":"Yes","Automatic Detection Of Transmission Rate":"Yes","Number of subscriptions per session, max.":"5","Limit class A, for use in industrial areas":"Yes; Group 1","Limit class B, for use in residential areas":"Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011","Limitation of inductive shutdown voltage to":"L+ (-48 V)","Number of monitored items, recommended max.":"1 000","User program protection/password protection":"Yes","Operation, tested according to IEC 60068-2-6":"Yes","Number of connectable IO Devices for RT, max.":"16","Protection Of Confidential Configuration Data":"Yes","Of The Pulse Outputs, With Resistive Load, Max.":"100 kHz","Number of IO Controllers with shared device, max.":"2","Of Which Inputs Usable For Technological Functions":"6; HSC (High Speed Counting)","Number of IO devices with prioritized startup, max.":"16","Number of position-controlled positioning axes, max.":"8","Resolution with overrange (bit including sign), max.":"10 bit","Number of nodes for user-defined server interfaces, max.":"2 000","Number of positioning axes via pulse-direction interface":"4; With integrated outputs","Retentive data area (incl. timers, counters, flags), max.":"14 kbyte","Number of IO Devices that can be simultaneously activated/deactivated, max.":"8"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$393.70 – $914.07","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d53e2b2bee576e28264d67239498fc46.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=142915&mlfb=6ES7215-1AG40-0XB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7215-1AG40-0XB0/alternatives.json"},"ai":{"faq":[{"question":"Does the 6ES7215-1AG40-0XB0 support DCP?","answer":"Yes, DCP (Discovery and Configuration Protocol) is listed as supported, enabling PROFINET network setup."},{"question":"Is FBD programming available on this CPU?","answer":"Yes, Function Block Diagram (FBD) is supported alongside LAD and SCL."},{"question":"What compliance documentation is available?","answer":"The CPU carries cULus and CE marks. For RoHS and REACH declarations, request the Siemens compliance pack with your order."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7215-1AG40-0XB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7215-1AG40-0XB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T14:33:38.484Z","lastPublished":"2026-09-02T14:33:38.484Z","indexable":true}}