{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7223-1PL30-0XB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7223-1PL30-0XB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7223-1PL30-0XB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7223-1PL30-0XB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SM 1223 signal module, 6ES7223-1PL30-0XB0, 16 digital inputs + 16 relay outputs, 16 A at 40 °C, 24 V DC input, IP20, 100 x 70 x 75 mm.","salesMarkdown":"## 16 inputs, 16 relay outputs — the I/O count that fits the BOM The 6ES7223-1PL30-0XB0: This SM 1223 packs 16 digital inputs and 16 relay outputs into a single S7-1200 expansion module. The input thresholds are standard 24 V DC: signal 0 at ≤5 V DC at 1 mA, signal 1 at ≥15 V DC at 2.5 mA — no level-shifting needed for most 24 V sensors. Relay outputs handle 5–250 V AC and 5–30 V DC, with a lamp-load limit of 30 W DC or 200 W AC. That covers solenoid valves, contactor coils, and indicator lamps without external interposing relays — but watch the inrush on incandescent loads. Operating temperature spans -40 to 70 °C, so cold-storage lines or hot cabinet corners are within range. IP20 means open-panel only — no washdown, no dust seal. ## Cable runs and diagnostics — 500 m shielded, 150 m unshielded Inputs accept cable runs up to 500 m shielded or 150 m unshielded. For remote sensor clusters near the machine perimeter, that's enough to keep the I/O rack central and still reach the far end of the line. Diagnostic alarm and status-of-inputs functions are built in — no separate signal-conditioning card needed for fault detection on the field wiring. ## Approvals and compliance — CE, FM, RCM That covers EU machinery directive, US FM for industrial control equipment, and Australian/New Zealand EMC. No UL or CSA listed in the spec — verify if your panel requires those specifically.","metaTitle":"Siemens 6ES7223-1PL30-0XB0 SM 1223, 16DI/16DO Relay, 16 A","metaDescription":"Siemens S7-1200 SM 1223 digital I/O module, 16 inputs + 16 relay outputs, rated 16 A at 40 °C. Active production, CE/FM/RCM. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Digital Input Modules"],"specifications":{"Max.":"70 °C","Min.":"-40 °C","Depth":"75 mm","Width":"70 mm","Alarms":"Yes","Height":"100 mm","CE mark":"Yes","Plastic":"Yes","FM approval":"Yes","In Groups Of":"4","For Signal \"0\"":"5 V DC at 1 mA","For Signal \"1\"":"15 V DC at 2.5 mA","Shielded, Max.":"500 m","For Maintenance":"Yes","Parameterizable":"Yes","Weight, approx.":"350 g","lifecycle_stage":"current","\"0\" To \"1\", Max.":"10 ms","\"1\" To \"0\", Max.":"10 ms","Diagnostic alarm":"Yes","Power loss, typ.":"10 W","Rated value (AC)":"5 V AC to 250 V AC","Rated value (DC)":"5 to 30 V AC","Unshielded, Max.":"150 m","Fall height, max.":"0.3 m; five times, in product package","On Lamp Load, Max.":"30 W with DC, 200 W with AC","up to 40 °C, max.":"16","up to 50 °C, max.":"8 A; Current per mass","Between The Channels":"Relays","Diagnostics function":"Yes","For Signal \"1\", Min.":"2.5 mA","For Signal \"1\", Typ.":"4 mA","RCM (formerly C-TICK)":"Yes","Type of input voltage":"DC","IP degree of protection":"IP20","Number of relay outputs":"16","Storage/transport, max.":"1 080 hPa","Storage/transport, min.":"660 hPa","For Status Of The Inputs":"Yes","Number of digital inputs":"16","Required Front Connector":"Yes","Short-circuit protection":"No; to be provided externally","For Status Of The Outputs":"Yes","Number of digital outputs":"16","With Inductive Load, Max.":"2 A","With Resistive Load, Max.":"2 A","Between Different Circuits":"750 V AC for 1 minute","Vertical Installation, Max.":"45 °C","Vertical Installation, Min.":"0 °C","Horizontal Installation, Max.":"55 °C","Horizontal Installation, Min.":"0 °C","Permissible Temperature Change":"5°C to 55°C, 3°C / minute","from backplane bus 5 V DC, max.":"180 mA","Number of operating cycles, max.":"mechanically 10 million, at rated load voltage 100 000","Between The Channels, In Groups Of":"4","permissible range, lower limit (DC)":"20.4 V","permissible range, upper limit (DC)":"28.8 V","Between The Channels And Backplane Bus":"1 500 V AC for 1 minute","For Signal \"1\" Permissible Range, Max.":"2 A","from load voltage L+ (without load), max.":"4 mA/input 11 mA/relay","Rated supply voltage of relay coil L+ (DC)":"24 V","Operation at 25 °C without condensation, max.":"95 %","Product Function / Supply Voltage For Transmitters":"Yes","For Signal \"0\", Max. (Permissible Quiescent Current)":"1 mA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$326.00 – $628.65","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4244e6711ca4776ca4f58c20846e85d2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=253780&mlfb=6ES7223-1PL30-0XB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7223-1PL30-0XB0/alternatives.json"},"ai":{"faq":[{"question":"What is the maximum cable length for the inputs?","answer":"Shielded cable runs up to 500 m, unshielded up to 150 m. For long sensor runs in noisy environments, shielded is the safe choice."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7223-1PL30-0XB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7223-1PL30-0XB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}