{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7231-5PD30-0XB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7231-5PD30-0XB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7231-5PD30-0XB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7231-5PD30-0XB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC S7-1200 SM 1231 RTD module, 8-channel, 6ES7231-5PD30-0XB0, RTD types Pt100 to LG-Ni1000, 24 V DC, -40 to 70 °C.","salesMarkdown":"## RTD selection and integration The 6ES7231-5PD30-0XB0: The module handles all the common industrial RTD types without needing separate conditioners: Pt10, Pt50, Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni200, Ni500, Ni1000, Cu10, Cu50, Cu100, and LG-Ni1000. Measurement is integrating (no thermocouple support – the thermocouple field shows 'No'). Diagnostics can be read out over the backplane, and the alarms are parameterizable (the alarm field says 'Yes'). That saves panel space by eliminating external alarm relays. For a bin that already holds standard S7-1200 modules, this RTD input drops into the same mounting rail and uses the standard 24 V DC supply. No separate sensor supply needed – the module provides excitation for two-wire RTDs. Wire-break detection per channel ('Wire-break Yes') flags open loops without additional hardware.","metaTitle":"Siemens 6ES7231-5PD30-0XB0 SM 1231 RTD, 8-ch, -40..70°C","metaDescription":"Siemens SIMATIC S7-1200 SM 1231 RTD input module, 8 channels, -40 to 70 °C, diagnostic alarm, wire-break detection, RTD types Pt100..Ni1000. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Analog Input Modules"],"specifications":{"Max.":"70 °C","Min.":"-40 °C","Cu 10":"Yes","Depth":"75 mm","Width":"45 mm","title":"6ES7231-5PD30-0XB0","Alarms":"Yes","Height":"100 mm","Ni 100":"Yes","Ni 120":"Yes","Ni 200":"Yes","Ni 500":"Yes","Pt 100":"Yes","Pt 200":"Yes","Pt 500":"Yes","CE mark":"Yes","Ni 1000":"Yes","Plastic":"Yes","Pt 1000":"Yes","LG-Ni 1000":"Yes","Resistance":"Yes; 150 Ω, 300 Ω, 600 Ω","Wire-break":"Yes","FM approval":"Yes","description":"***Spare part*** SIMATIC S7-1200, Analog input, SM 1231 RTD, 4xAI RTD module","Thermocouple":"No","0 To 150 Ohms":"Yes","0 To 300 Ohms":"Yes","0 To 600 Ohms":"Yes","For Maintenance":"Yes","Operation, max.":"1 080 hPa","Operation, min.":"795 hPa","Parameterizable":"No","Weight, approx.":"220 g","lifecycle_stage":"current","Diagnostic alarm":"Yes","Power loss, typ.":"1.5 W","Rated value (DC)":"24 V","Fall height, max.":"0.3 m; five times, in product package","Diagnostics function":"Yes; Can be read out","Measurement principle":"integrating","RCM (formerly C-TICK)":"Yes","Resistance thermometer":"Yes; Resistance-type transmitter: Pt10, Pt50, Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni200, Ni500, Ni1000, Cu10, Cu50, Cu100, LG-Ni1000","IP degree of protection":"IP20","Number of analog inputs":"4; Resistance thermometer","Storage/transport, max.":"1 080 hPa","Storage/transport, min.":"660 hPa","For Status Of The Inputs":"Yes","Input resistance (Cu 10)":"10 Ω","Required Front Connector":"Yes","Current consumption, typ.":"40 mA","Input resistance (Ni 100)":"100 Ω","Input resistance (Ni 120)":"120 Ω","Input resistance (Ni 200)":"200 Ω","Input resistance (Ni 500)":"500 Ω","Input resistance (Pt 100)":"100 Ω","Input resistance (Pt 200)":"200 Ω","Input resistance (Pt 500)":"500 Ω","Input resistance (Ni 1000)":"1 000 Ω","Input resistance (Pt 1000)":"1 000 Ω","Vertical Installation, Max.":"45 °C","Vertical Installation, Min.":"0 °C","Horizontal Installation, Max.":"55 °C","Horizontal Installation, Min.":"0 °C","Input resistance (LG-Ni 1000)":"1 000 Ω","Monitoring the supply voltage":"Yes","Common mode interference, min.":"120 dB","from backplane bus 5 V DC, typ.":"80 mA","Integration time, parameterizable":"No","SO2 at RH < 60% without condensation":"S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free","Operation at 25 °C without condensation, max.":"95 %","Temperature error (relative to input range), (+/-)":"25 °C ±0.1%, to 55 °C ±0.2% total measurement range","Resolution with overrange (bit including sign), max.":"15 bit; + sign","Technical unit for temperature measurement adjustable":"Degrees Celsius/degrees Fahrenheit","Interference voltage suppression for interference frequency f1 in Hz":"85 dB at 50 / 60 / 400 Hz","Permissible Input Voltage For Voltage Input (Destruction Limit), Max.":"±35 V","Repeat accuracy in steady state at 25 °C (relative to output range), (+/-)":"0.05 %"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$517.78","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4e1b047c88d7a611c8aaabc85bee0854.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=475342&mlfb=6ES7231-5PD30-0XB0"},"ai":{"faq":[{"question":"What is the temperature range of this RTD module?","answer":"It operates from -40 °C to 70 °C, making it suitable for cold storage environments or non-conditioned cabinets."},{"question":"What RTD types does it support?","answer":"It supports Pt10, Pt50, Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni200, Ni500, Ni1000, Cu10, Cu50, Cu100, and LG-Ni1000, plus direct resistance measurements up to 600 Ω."},{"question":"Does it have diagnostic alarms or wire-break detection?","answer":"Yes, a diagnostic alarm is available and can be read out over the backplane. Wire-break detection is also included per channel, so you'll see a fault if an RTD lead opens."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7231-5PD30-0XB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7231-5PD30-0XB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}