{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7238-5XA32-0XB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7238-5XA32-0XB0","canonicalUrl":"https://aoctrl.com/siemens/6ES7238-5XA32-0XB0","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7238-5XA32-0XB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SM 1238 energy meter, 6ES7238-5XA32-0XB0, 45 x 100 x 75 mm, 165 g, current production, DC supply, sinusoidal or distorted voltage curve.","salesMarkdown":"## Panel fit and wiring constraints The 6ES7238-5XA32-0XB0: Supply is 24 V DC (type of supply voltage DC). ## What it measures and how it alarms This is a multi-function energy meter for the S7-1200: it measures voltage, current, active power, energy, and frequency in a single module. It handles both sinusoidal and distorted voltage waveforms — important for VFD-fed motor circuits where harmonics are present. Zero point suppression is parameterizable from 2 to 250 mA (default 50 mA), so you can ignore idle current on lightly loaded phases. Diagnostic and limit value alarms are built in — green/red DIAG LED for module status, red Fn LED per channel for faults, and green LED per channel for status. I&M data (I&M 0) is supported for asset tracking. Firmware version is V2.0.1; HW functional status from FS02. No isochronous mode, no hardware interrupt — this is a data acquisition module, not a fast safety input. ## Approvals and lifecycle Current production — no obsolescence notice on record. The module carries CE, cULus, UL, CSA, FM, KC, marine, and RCM (formerly C-TICK) approvals. Isolation tested at 2 300 V AC for 1 minute (type test). Parameter length is 74 bytes; cyclic, acyclic, and cyclic measurement modes are all supported.","metaTitle":"Siemens 6ES7238-5XA32-0XB0 SM 1238 Energy Meter, 45 mm","metaDescription":"Siemens SM 1238 energy meter for S7-1200. 45 x 100 x 75 mm, 165 g. Current production. CE, cULus, UL, CSA, FM, KC, marine, RCM. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Analog Input Modules"],"specifications":{"Depth":"75 mm","Width":"45 mm","cULus":"Yes","Height":"100 mm","CE mark":"Yes","Present":"Yes","I&M data":"Yes; I&M 0","FM approval":"Yes","KC approval":"Yes","UL approval":"Yes","CSA approval":"Yes","Surge strength":"10 A; for 1 minute","Marine approval":"Yes","Weight, approx.":"165 g","lifecycle_stage":"current","Diagnostic alarm":"Yes","Firmware version":"V2.0.1","Isochronous mode":"No","Parameter length":"74 byte","Power loss, typ.":"0.75 W","Limit value alarm":"Yes","Mounting position":"Horizontal, vertical","Power measurement":"Yes","Cyclic Measurement":"Yes","Energy measurement":"Yes","Hardware interrupt":"No","Acyclic Measurement":"Yes","Current measurement":"Yes","Voltage measurement":"Yes","HW functional status":"From FS02","Frequency measurement":"Yes","Isolation tested with":"2 300V AC for 1 min. (type test)","RCM (formerly C-TICK)":"Yes","Channel status display":"Yes; green LED","Curve shape of voltage":"Sinusoidal or distorted","For Module Diagnostics":"Yes; green/red DIAG LED","Type of supply voltage":"DC","Zero point suppression":"Parameterizable: 2 ... 250 mA, default 50 mA","For Channel Diagnostics":"Yes; red Fn LED","Active power measurement":"Yes","With Current Transformer":"Yes","With Voltage Transformer":"Yes","Current consumption, max.":"180 mA","Fixed measured value sets":"Yes","Measured variable current":"0,2","Measured variable voltage":"0,2","Design of the power supply":"from CPU","Reactive power measurement":"Yes","Calibration possible in RUN":"Yes","Frequency measurement, max.":"65 Hz","Frequency measurement, min.":"45 Hz","Measured variable frequency":"0.05","Power consumption per phase":"20 mW","Vertical Installation, Max.":"50 °C","Vertical Installation, Min.":"-20 °C","Without Current Transformer":"No","Acyclic measured value access":"Yes","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"-20 °C","Measured variable phase angle":"±1 °; not covered by IEC 61557-12","Address space per module, max.":"124 byte; 112 byte input / 12 byte output","Measured variable active power":"0.5","Measured variable power factor":"0.5","Buffering of measured variables":"Yes","Cycle time (all channels), typ.":"50 ms; Time for consistent update of all measured and calculated values (cyclic und acyclic data)","Measured variable active energy":"0.5","Measured variable apparent power":"0.5","Measured variable reactive power":"1","Measured variable neutral current":"0.5; calculated","Measured variable reactive energy":"1","Reparameterization possible in RUN":"Yes","Type of measured value acquisition":"seamless","Freely definable measured value sets":"No","Impulse voltage resistance 1,2/50μs":"1 kV","Between The Channels And Backplane Bus":"Yes; 3 700V AC (type test) CAT III","measurable relative current (AC), max.":"100 %; Relative to the secondary rated current 5 A","measurable relative current (AC), min.":"1 %; Relative to the secondary rated current 5 A","Bandwidth of measured value acquisition":"2 kHz; Harmonics: 39 / 50 Hz, 32 / 60 Hz","Input resistance measuring range 0 to 5 A":"25 mΩ; At the terminal","Monitoring of the supply voltage (PWR-LED)":"Yes","Burden power current transformer x/1A, min.":"As a function of cable length and cross section, see device manual","Burden power current transformer x/5A, min.":"As a function of cable length and cross section, see device manual","Measuring procedure for current measurement":"TRMS","Measuring procedure for voltage measurement":"TRMS","Continuous current with AC, maximum permissible":"5 A","Measurable line voltage between the line conductors":"480 V","STEP 7 TIA Portal configurable/integrated from version":"V13 SP1","Internal resistance line conductor and neutral conductor":"3.4 MΩ","Measurable line voltage between the line conductors, max.":"508 V","Measurable line voltage between the line conductors, min.":"0 V","Rated value short-time withstand current restricted to 1 s":"100 A","Measurable line voltage between phase and neutral conductor":"277 V","Apparent power consumption per phase for measuring range 5 A":"0.6 VA","Measurable line voltage between phase and neutral conductor, max.":"293 V","Measurable line voltage between phase and neutral conductor, min.":"0 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$218.44","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9e0e82f335da8d8ab928c4c2fd72d2ad.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=696208&mlfb=6ES7238-5XA32-0XB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6ES7238-5XA32-0XB0/alternatives.json"},"ai":{"faq":[{"question":"What approvals does 6ES7238-5XA32-0XB0 carry?","answer":"CE, cULus, UL, CSA, FM, KC, marine, and RCM (formerly C-TICK). Isolation tested at 2 300 V AC for 1 minute type test."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7238-5XA32-0XB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7238-5XA32-0XB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}