{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6ES7288-1CR20-0AA1","brand":"Siemens","brandSlug":"siemens","productSlug":"6ES7288-1CR20-0AA1","canonicalUrl":"https://aoctrl.com/siemens/6ES7288-1CR20-0AA1","factsUrl":"https://aoctrl.com/api/mcp/products/6ES7288-1CR20-0AA1","rawCanonicalId":null},"summary":{"shortDescription":"SIMATIC S7-200 SMART CPU CR20s, COMPACT CPU, AC/DC/RELAY, ONBOARD I/O: 12 DI 24V DC; 8 DO RELAY 2A; POWER SUPPLY: AC, 85 - 264 V AC AT 47 - 63 HZ, PROGRAM/DATA MEMORY: 20 KB","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["DIN Rail Power Supplies"],"specifications":{"FBD":"Yes","LAD":"Yes","RAM":"Yes","STL":"Yes","Max.":"70 °C","Min.":"-40 °C","Type":"Software clock","Depth":"81 mm","Flash":"Yes","Width":"90 mm","Height":"100 mm","RS 485":"Yes","TCP/IP":"No","CE mark":"Yes","120 V AC":"Yes; 85 to 132 V AC","230 V AC":"Yes; 170 to 264 V AC","Isolated":"Yes; 500 V AC or 707 V DC","PROFIBUS":"No","Rail mounting":"Yes; Standard - DIN rail","For Signal \"0\"":"< 5 V DC","For Signal \"1\"":"+15 to +30 V","Interface type":"RS 485 (max. 187.5 kbps)","Shielded, Max.":"500 m","Type of memory":"DDR","Parameterizable":"Yes","Weight, approx.":"365 g; approx.","lifecycle_stage":"current","\"0\" To \"1\", Max.":"10 ms; max.","\"1\" To \"0\", Max.":"10 ms; max.","Power loss, max.":"6 W","Rated value (AC)":"230 V; 230 V AC (L1, N)","Rated value (DC)":"24 V; DC at 4 mA nominal","Unshielded, Max.":"300 m","Fall height, max.":"0.5 m; five times, in product package","Micro Memory Card":"No","Optical interface":"No","Source/sink input":"Yes","On Lamp Load, Max.":"30 W; 30 W with DC, 200 W with AC","At \"0\" To \"1\", Max.":"12.8 µs","At \"0\" To \"1\", Min.":"0.2 µs","Programming package":"STEP 7 Micro/WIN SMART","For Signal \"1\", Typ.":"4 mA","Inrush current, max.":"16.3 A; at 264 V","Type of input voltage":"DC","IP degree of protection":"IP20","Integrated power supply":"No","Number of relay outputs":"8","Storage/transport, max.":"1 080 hPa","Storage/transport, min.":"660 hPa","Design of the connection":"9-pin sub D socket","For Bit Operations, Typ.":"150 ns; / instruction","Number of digital inputs":"12; Integrated","Current consumption, max.":"80 mA; At 220 V AC","For Word Operations, Typ.":"1.2 µs; / instruction","Number of digital outputs":"8; Relays","With Resistive Load, Max.":"2 A","Hardware clock (real-time)":"No","Installation altitude, max.":"2 000 m","Installation altitude, min.":"-1 000 m","Number of RS 485 interfaces":"1","Reverse polarity protection":"No","Vertical Installation, Max.":"45 °C","Vertical Installation, Min.":"0 °C","Horizontal Installation, Max.":"55 °C","Horizontal Installation, Min.":"0 °C","Test voltage at air discharge":"8 kV","Test voltage on supply cables":"2 kV","Permissible Range, Lower Limit":"47 Hz","Permissible Range, Upper Limit":"63 Hz","Number of operating cycles, max.":"10 000 000; mechanically 10 million, at rated load voltage 100 000","Current consumption (rated value)":"60 mA; At 220 V AC","Supports protocol for PROFINET IO":"No","Test voltage at contact discharge":"4 kV","Test voltage on signal cables >30m":"2 kV","For Floating Point Arithmetic, Typ.":"3.6 µs; / instruction","Frequency range of the RF radiation":"10 V/m for 80 MHz ~ 1 GHz, 3 V/m for 1.4 GHz ~ 2 GHz, 3 V/m for 87 MHz ~ 108 MHz, 174 MHz ~ 230 MHz, 470 MHz ~ 790 MHz, 1.4 GHz ~ 2 GHz, 1 V/m for 2 GHz ~ 2.7 GHz","permissible range, lower limit (AC)":"85 V","permissible range, lower limit (DC)":"5 V","permissible range, upper limit (AC)":"264 V","permissible range, upper limit (DC)":"250 V","Number of industrial Ethernet interfaces":"0","Limit class A, for use in industrial areas":"Yes; Emission of radio interference acc. to EN 61000-6-4 +A1 for use in industrial environments","Operation at 25 °C without condensation, max.":"95 %","Of The Pulse Outputs, With Resistive Load, Max.":"1 Hz","Interference emission via line/AC current cables":"EN 61000-6-4, interference emission: Intended for use in industrial areas.","Of Which Inputs Usable For Technological Functions":"4; HSC: 4 @ 100 kHz single phase, 2 @ 50 kHz A/B phase","For Signal \"0\", Max. (Permissible Quiescent Current)":"1 mA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2eae11b0b4bedb55f7a0d8d9ec5cbeae.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1035134&mlfb=6ES7288-1CR20-0AA1"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6ES7288-1CR20-0AA1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6ES7288-1CR20-0AA1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}